Haier HCC2230AGS Installation Instructions Manual

Other manuals for HCC2230AGS: User Manual
Manual is about: 24” and 30” Gas Cooktops

Summary of HCC2230AGS

  • Page 1

    24” and 30” gas cooktops tables de cuisson à gaz de 24” et 30” superficies de cocción a gas de 24” y 30” installation instructions instructions d’installation instrucciones de instalación hcc2230ags hcc3230ags on min off on min off on min off on min off.

  • Page 2: Installation Instructions

    Installation instructions installation and service must be performed by a qualified installer. Important: save these instructions for local electrical inspector's use. Read and save these instructions for future reference. Advance preparation • for proper operation of a gas appliance, the air necess...

  • Page 3

    • a range hood with minimum 350 cfm that projects at least 5” beyond front of cabinets can reduce risk of burns caused by reaching over heated surface units. Provide an adequate gas and electrical supply • installation must comply with local codes. In the absence of local codes, the gas cooktop must...

  • Page 4: Cutting The Countertop

    Tools and materials needed materials you will need: joint sealant pipe fittings shut-off valve csa-approved flexible ½” or ¾” gas line tools you will need: pencil phillips-head screwdriver ruler safety glasses saber saw pipe wrench 1/8” drill bit & electric or hand drill cutting the countertop 1) us...

  • Page 5

    2) cut the opening in the countertop. To ensure accuracy it is best to make a template (see figure 9) for the opening. Make sure the sides are parallel also rear and front cuts are exactly perpendicular to the sides. Observe all minimum clearances. 3) before inserting the cooktop into the opening in...

  • Page 6

    5) secure cooktop from underneath with the supplied clips and screws (see figure 12). Installing the pressure regulator warning: never reuse old flexible connectors. The use of old flexible connectors can cause gas leakage and personal injury. Always use new flexible connectors when installing a gas...

  • Page 7

    • the gas supply line must be equipped with an approved manual shut-off valve. In an easily accessible location in the same room as the cooktop. Do not block access to the shutoff valve. Be sure you know how and where to shut off the gas supply to the cooktop. Install the electrical outlet 12” below...

  • Page 8: Electrical Connection

    6) after connecting the cooktop to the gas supply, make sure all burners knobs are in the off position and check the system for leaks with a manometer. If a manometer is not available, turn on the gas supply and use a liquid leak detector (or soap and water) at all joints and connections to check fo...

  • Page 9: Assembling The Burners

    Assembling the burners the electrode of the electronic ignition system is positioned above the surface of the burner base. Do not remove a burner cap or touch the electrode of a burner while another is turned on. Damage or electrical shock may occur. 1. Place burner heads over the burner base. Make ...

  • Page 10: Lp/propane Gas Conversion

    3. Operation of the electric igniters should be tested after the cooktop and supply line have been carefully checked for leaks and the cooktop has been connected to the electrical power. To check igniters, push and turn a burner valve to the lite position. All spark igniters will make a series of sp...

  • Page 11

    The conversion must be performed by a qualified service technician in accordance with the kit instructions and all local codes and requirements. Failure to follow instructions could result in serious injury or property damage. The qualified agency performing this work assumes responsibility for the ...

  • Page 12

    1) unscrew the regulator cap with the wrench (see figure 19). 2) this is how the retainer pin looks for natural gas usage (see figure 20). 3) remove the retainer pin (see figure 21). Figure 19 figure 20 figure 21.

  • Page 13

    4) reverse the retainer pin and put back into the regulator cap. This is how the regulator pin looks for lp gas usage (see figure 22). 5) screw the regulator cap back into the regulator and re-attach the regulator to the nipple and flare union (see figures 14 and 23). B. Change burner nozzles instal...

  • Page 14

    Important: carefully read and observe each nozzle label for correct location (see figure 18). 3) install the proper nozzles in the exact locations as noted in the illustrations above (see figure 24). 4) replace the burner bases, heads, caps and top grates. Make sure burner caps are properly seated o...

  • Page 15

    - to adjust the flame, remove the knobs, insert a screwdriver through the access hole in valve shaft as shown (see figure 25). Make the adjustment by slowly turning the screw until flame appearance is correct. - if the flames are too small or fluttered, open the valve more than the original setting....

  • Page 16: Important

    Important do not return this product to the store if you have a problem with this product, please contact the “haier customer satisfaction center” at 1-877-337-3639. Dated proof of purchase, model #, and serial # required for warranty service important ne pas réexpédier ce produit au magasin pour to...