Haier HLF11P User Manual

Other manuals for HLF11P: User Manual
Manual is about: Haier HLF11P: User Manual

Summary of HLF11P

  • Page 1

    Heavy duty towels/cotton cycles more dry less dry dry cool down cycle completed extend trumble customer gdz22-2 louder softer off cycle signal bulky items casual delicate on off wrinkle care timed cycles more time less time auto dry rack dry timed dry time remaining(min) time on(hour) delay start on...

  • Page 2: Warning

    Warning.

  • Page 5

    4 tables of contents page safety instructions ............................................................................ 1 operating instructions ............................................................ 5 .......................................................... 5 other features ................

  • Page 6

    Understanding the control panel operating instructions 1 2 9 3 7 6 5 4 10 power on/off button: (1) start/pause button: (2) press the button once to operate the dryer. Press the button once again to turn the dryer "off". Press this button once to start the dry process. Press this button once again to...

  • Page 7

    Timed/cycles button: (5) cycles button: (7) more time & less time button: (6) "cycle" button will let you select your desired dry cycles. For your convenience, there are seven fabric care dry cycles programmed in this mode:customer, normal, heavy duty, towels/cotton, delicate, casual and bulky items...

  • Page 8

    Status lights: (11) status lights give notification of which part of the cycle the machine is in. Understanding the function light indicator: the function "display light" indicates selected feature is "on" or the cycle is about to begin. During the dry cycle, "flashing light" indicates current runni...

  • Page 9

    Auto dry cycle and timed dry cycle load clothes into dryer the appropriate load shall be 1/3 ~ 1/2 of the drum volume. Avoid too much load, for a certain space is needed to allow clothes free rotation for uniform and wrinkle- proof drying. When drying big articles, only 2-3 pieces shall be loaded at...

  • Page 10

    Various button initial status for "normal program" 2. Press "cycles" button to select a suitable full automatic cycle the normal program will be automatically selected after powering on. If other full automatic program is desired, press "auto-program selection" button until corresponding indicator t...

  • Page 11

    After powering on, the clothes dryer automatically sets dryness at "more dr y", which means the normal drying time. If other drying time is desired, press "dryness level" button to select a shorter time. 3. Press "dryness level" button to select a suitable drying time after switching on, the dryer s...

  • Page 12

    Timed dry cycle 1 8 4 7 2 6 cycles more dry less dry dry cool down cycle completed extend trumble customer on off wrinkle care more time less time auto dry rack dry timed dry time remaining(min) time on(hour) delay start on/off power pause start temp level dryness air only(no heat) high medium low n...

  • Page 13

    Other features 2. Press "timed/cycles" button and select "rack dry" cycle 1. Press "power on/off" button to power on after powering on, press "timed/cycle" button to select "rack dry" program. 3. Press "more time" and "less time" buttons to set a suitable time after setting "timed/cycle" to "rack dr...

  • Page 14

    Other features 2. Press "timed/cycles" button and select "rack dry" cycle 1. Press "power on/off" button to power on after powering on, press "timed/cycle" button to select "rack dry" program. 3. Press "more time" and "less time" buttons to set a suitable time after setting "timed/cycle" to "rack dr...

  • Page 15

    13.

  • Page 16

    14.

  • Page 17

    15.

  • Page 18

    16.

  • Page 19

    17.

  • Page 20

    18.

  • Page 21

    19.

  • Page 22

    Do not install your dryer: in an area exposed to dripping water or outside weather conditions. In an area where it will come in contact with curtains, thick carpet, or anything that will obstruct the flow of combustion and ventilation air. On carpet. Floor must be solid with a maximum slope of 1inch...

  • Page 23

    Dryer must be exhausted outside (outdoors, not beneath the mobile home) using metal ducting that will not support combustion. Metal ducting must be 4 inches (10.16 cm) in diameter with no obstructions. Rigid metal duct is preferred. If dryer is exhausted through the floor and area beneath the mobile...

  • Page 24

    22.

  • Page 25

    Thermal limiter l2 l1 n motor circuit control thermostat relay heater computer program controller thermostat high limit switch door 23.

  • Page 26

    24 circuit control thermostat heater computer program controller relay thermostat high limit switch door l2 n l1 limiter thermal motor e circuit.

  • Page 27

    25.

  • Page 28

    Specifications model hlf11p rated voltage , frequency 120v/240v~ 60hz rated dry capacity 10 kg rated dry power 5000w weight (about) 55 kg dimension l712mm w686mm h1115mm.