Haier HSU-09RR03-R2 Installation Manual

Other manuals for HSU-09RR03-R2: Operation Manual
Manual is about: SPLIT TYPE ROOM AIR CONDITIONER

Summary of HSU-09RR03-R2

  • Page 1

    No. Accessory parts remote controller r-03 dry battery mounting plate drain hose screw plastic cap 1 1 2 3 4 5 6 7 8 9 10 2 1 1 4 drain-elbow cushion 1 4 number of articles accessory parts 4x25 change for fresh air box change for fresh air tube(suit) outlet joint 1 1 2 no.00105 installation manual o...

  • Page 2

    Fixing of outdoor unit indoor unit selection of installation place power source selection of pipe outdoor unit fix the unit to concrete or block with bolts( 10mm) and nuts firmly and horizontally. When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails or wires in c...

  • Page 3: Indoor Unit

    Indoor unit 1.Fitting of the mounting plate and positioning of the wall hole 2.Making a hole on the wall and fitting the piping hole cover when the mounting plate is first fixed when the mounting plate is fixed side bar and lintel 1.Carry out, based on the neighboring pillars or lintels, a proper le...

  • Page 4: Indoor Unit

    Indoor unit 4.Connecting the indoor/outdoor electric cable fixing the indoor unit body removing the wiring cover [other direction piping] indoor/outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape. Cut away, with a nipper, the lid for piping according to th...

  • Page 5: Indoor Unit

    Indoor unit two ways for the installation of indoor part, as illustrated: way one (right direction): take off the lid for right piping pipe,put the outlet joint into the lid,then put the fresh air tube into the outlet jont. Way two (left direction): take off the lid for leftt piping pipe,put the out...

  • Page 6

    Outdoor unit 1.Installation of outdoor unit 2.Connection of pipes install according to to bend a pipe, give the roundness as large as possible not to crush the pipe ,and the bending radius should be 30 to 40 mm or longer. Connecting the pipe of gas side first makes working easier. The connection pip...

  • Page 7: Outdoor Unit

    Outdoor unit 3.Connection 4.Attaching drain-elbow use the same method on indoor unit. Loosen the screws on terminal block and insert the plugs fully into terminal block, then tighten the screws. If wiring is not correct, proper operation can not be carried out and controller may be damaged. If the d...

  • Page 8: Outdoor Unit

    Outdoor unit 6.Purging method:to use vacuum pump detach the service port's cap of 3-way valve, the valve rod's cap for 2-way valve and 3-way's, connect the service port into the projection of charge hose (iow) for gaugemanifold. Then connect the projection of charge hose (center) for gaugemanifold i...

  • Page 9: 1.Power Source Installation

    1.Cut pipe 3.Insert the flare nut 4.Flare pipe it becomes high midway. The end is immersed in water. It waves. The gap with the ground is too small less than 5cm there is the bad smell from a ditch 2.Remove burs 0~0.5mm 1.0~1.5mm 1.5~2.0mm flare tool for r410a clutch-type conventional flare tool clu...

  • Page 10

    Ce tutti i prodotti sono conformi alle seguenti normative europee: - direttiva 73/23/eec basso voltaggio - direttiva 2006/95/ec basso voltaggio - direttiva 89/336/eec compatibilità elettromagnetica - direttiva 2004/108/ec compatibilità elettromagnetica rohs il prodotto è conforme alla normativa 2002...

  • Page 11

    Haier industrial park, no.1 haier road, qingdao, p.R.China ce todos los productos están en conformidad con las siguientes normativas europeas: - bajo voltaje directiva 73/23/eec - bajo voltaje directiva 2006/95/ec - compatibilidad electromagnética 89/336/eec - compatibilidad electromagnética 2004/10...

  • Page 12: R410A

    Questo prodotto contiene gas fluorurati ad effetto serra inclusi nel protocollo di kyoto. Non liberare tali gas nell’atmosfera. Tipo di refrigerante: r410a valore gwp*: 1975 * gwp = potenziale di riscaldamento globale compilare con inchiostro indelebile, • 1 la carica di refrigerante di fabbrica del...

  • Page 13: R410A

    Haier industrial park, no.1 haier road, qingdao, p.R.China 1 1+2= kg r410a 2 kg 2= 1= b c d f e kg contain s fluorinated greenhou s e ga s e s covered by the kyoto protocol a este producto contiene los gases fluorados de efecto invernadora regulados por el protocolo de kioto. No vierta gases a la at...