SELECTION OF THE INSTALLATION POSITION
THE ENCLOSED ACCESSORIES OF THE CONDITIONER
INSTALLATION PROCEDURES
PREPARATIONS BEFORE INSTALLATION
AIR CONDITIONER INSTALLATION
4
TROUBLESHOOTING
5
If problems can not be solved please pull out power plug and contact
your dealer.
Before calling for service.
Check the following points before calling for repairs or service.
Is plug firmly inserted?
Is there power failure?
Readjust power supply
Is thermostat switch
wrongly adjusted?
Readjust the thermostat.
Is there any direct
sunlight in the room?
Use curtain or blind.
Are doors or windows
left open?
Shut doors and windows.
Are there any obstacles
blocking air inlet and
outlet?
Remove the obstacles.
Is there too much heat
source in the room?
Is air filter clogged?
Clean it.
Remove the heat source
Does fuse get burned?
Phenomenon
Solution
Cause or check points
Replace fuse.
Fig.1
Wall
Water outlet flexible
pipe(provide by user)
1. Fix the prefabricated iron frame to stable position by expansible screws.
2. Put the whole machine with all the accessories installed,
on the iron frame. If there's water outlet flexible pipe, lead it
to needed position(see Fig.1).
3. Fill any distance between the wall hole and the machine body with flexible sponge rubber strip to
prevent the entering of outer noise and the leaking of the coolness.
4. After installation of the conditioner, insert the power plug into the outlet and perform test-run.
Make the wall hole or window hole (see Fig.1)
Fig. 1
A
B
Width of the wall
Iron frame
MODEL
A
B
440mm
635mm
395mm
615mm
370mm
485mm
1,The air-conditioner is better installed in shadow or in a place
with short period of sunshine. In case the air-conditioner is
installed at the point exposed directly to the sunshine, it should
be protected from the direct sunlight as possible in order to
avoid the long time of direct sunlight otherwise its performance
will be lowered. (As illustrated in Fig. 1).
2. For the convenience of operation, it is
recommended that air-conditioner be installed at
least at the height of 760-1300 mm above the
floor and no obstacles before it for a free airflow.
3.The shutters at both sides and the top of
air-conditioner should be protruded outdoors
free from being blocked by wall, window,ect.
4.The back of air-conditioner should be kept
over 500mm from the obstacles (for example,
wall, etc.) (As illustrated in Fig. 2).
5.To have an efficient drainage, the back part of
the air-conditioner should be inclined downward
by 5-10mm (As illustrated in Fig. 3).
Install air-con at a place strong enough to support the unit.
Leave enough space around air inlet and outlet for better circulation.
Avoid places where flammable gas leaks.
Problems may occur if unit is installed in the following places:
Place where oil exists in the air including engine oil or seaside with
salt breeze blows and hot spring area with sulphurous gas in the air.
For longer and trouble-free operation of the unit, pay special attention to the following:
NOTES:
Drain pan
Sealed gasket
Screw
Manual
Rubber lid
Name
Figure
Quantity
(ONLY FOR REFERANCE)
cover
support
fig.1
>500mm
fig.2
5-10mm
fig.3
Cautions
Power cord: Be sure to use the exclusive power cord.
Always use at the rated voltage and with specfic air conditioning circuit
Change installation place: If air-con need to be changed to another
place please contact the dealer, who sold you the unit.
1.Take out the conditioner and
accessories from the package .
2.Disposal of the condensed water.
Prepare unit for installation:
Install
Drain pan to the bottom hole.which can
make the condensed water flow out from the
bottom plate. (See Fig.1)
If necessary the above method can
have extra pipe added on the Drain pan
(available on the market).
Drain pan
Screw
Condenser
Fig.1
Bottom plate hole
Switch on the machine but it
does not work immediately.
If the machine is started after stop,it will need about 3 minutes to
re-start so as to prevent the fuse from break.
Switch on the machine but it
does not work.
The cooling effect is not good.
Paper guard
To ensure the safty in
transportation, some machines
are fixed paper guard by the
side of the machine (as figure
shows).Please check and
remove the paper guard first
before you fixed your machine.
Cautions
HW07M
HW09M
HW12M
HW18M
1
1
1
1
4