Hokkaido HKED - HCND 261 X(-1) User Manual

Manual is about: WALL-MOUNTED TYPE AIR CONDITIONERS

Summary of HKED - HCND 261 X(-1)

  • Page 1

    - 1 - wall-mounted type air conditioners (split systems, air-to-air, heat pump type) user’s manual warning: please read carefully this manual before operating your new air conditioner . R410a hked - hcnd 261 x (-1) hked - hcnd 351 x (-1) hked - hcnd 511 x (-1) hked - hcnd 631 x (-1) new smartline 20...

  • Page 2

    - 2 - it ce all the products are in conformity with the following european provision: - low voltage directive 73/23/eec - low voltage directive 2006/95/ec - electromagnetic compatibility 89/336/eec - electromagnetic compatibility 2004/108/ec rohs the products are fulfilled with the requirements in t...

  • Page 3

    - 3 - table of contents general information ....................................................................................................... 4 safety precautions ......................................................................................................... 6 indoor and outdoor’s un...

  • Page 4

    - 4 - dust filter the indoor unit is equipped with a high-efficency filter which do grant a higher comfort and a healthy air quality inside the room. Infrared remote controller all available functions of the air conditioner must be set using the infrared remote controller, whose lcd panel shows imme...

  • Page 5

    - 5 - thermostat under microcomputer control the thermostat being controlled by microcomputer allows remarkable energy saving and provides more comfort, as the room temperature is checked with the greatest precision. Indoor fan with low sound level the indoor fan has been conceived and developed to ...

  • Page 6

    - 6 - safety precautions disposal of an old air conditioner before disposing an old air conditioner, please make sure it is inoperative and carry out the disposal by adopting all safety precautions. Unplug it from the power line in order to avoid risks of electric shock. Please remember that an air ...

  • Page 7

    - 7 - safety precautions safety instructions • please read carefully the following safety instructions before operating the air conditioner. • a strict observance of the instructions indicated in this "user's manual" will prevent personal hurt and incidents to the user. Moreover, correct operation a...

  • Page 8

    - 8 - safety precautions installation never try to install this unit by yourself, i.E. Without the support of tachnical personnel. Never try to reapir the unit by yourself. The unit's components can be reached only by opening or removing the covering panels, and this involves exposure to high voltag...

  • Page 9

    - 9 - safety precautions always observe the operating precautions listed in the following tables. In this way, correct operation and safeguard of people, animals and objects inside the air-conditioned room will be ensured. Warning ! Use the correct voltage and frequency for power supply. Do not inse...

  • Page 10

    - 10 - safety precautions caution ! ! ! ! Do not use sprays near the air conditioner and do not spray anything towards the appliance. Do not expose plants or animals to the direct airflow of the air conditioner. Ventilate the room regularly while the air conditioner is operating. Fail to follow this...

  • Page 11

    - 11 - indoor and outdoor’s units outline the figure below is for explanation purpose only. The real appearance of the components could be rather different. Indoor unit outdoor unit unit operation section air return grid takes in the indoor air left/right air flow direction adjusting fin operational...

  • Page 12

    - 12 - to obtain the best performances from the unit, it is recommended its use under the following conditions: note: if the unit operates in rooms which are satured with oil vapors or volatile matters, harmful substances could coat and clog the indoor unit heat exchanger. Besides, scalings of saltn...

  • Page 13

    - 13 - remove the cover of the batteries’ box by sliding it as indicated on the cover itself. Replace used batteries with new ones. Pay attention to insert them correctly according to polarities. After replacing the batteries, press “rst” button (“reset”) on remote controller. If remote controller i...

  • Page 14

    - 14 - outline of the remote controller’s buttons infrared remote controller set temperature on/off swing air flow sleep lamp hold mode fan speed turbo timer note: when turbo operation is selected, room temperature is not controlled. If you feel the room temperature is too cool or too heat, please c...

  • Page 15

    - 15 - outline of the remote controller’s display infrared remote controller temperature this indicator shows the set temperature. The room temperature range is from 16°c to 32°c. (temperature is automatically set at 25°c and unadjustable in auto mode and dry mode). Auto mode this indicator shows th...

  • Page 16

    - 16 - heat, cool, fan operation heat, cool, fan modes selection to start operation: point the remote controller at the unit, press the on/off button and select the needed mode: 1. Select your desired operating mode by pressing mode button: • cool (cooling operation ) • heat (heating operation ) • f...

  • Page 17

    - 17 - dry operation dry mode selection to start operation: point the remote controller at the unit, press the on/off button and select the needed mode: 1. Press the mode button and select dry mode. In dry mode, temperature is automatically set at 25°c and unadjustable. Fan speed is automatically se...

  • Page 18

    - 18 - auto operation auto mode selection to start operation: point the remote controller at the unit, press the on/off button and select the needed mode: 1. Press the mode button and select auto mode. 2. Select your desired speed for indoor unit's fan by pressing fan speed button: - low ( is displa...

  • Page 19

    - 19 - sleep operation sleep mode selection sleep mode can be used to reduce operation sound when sleeping or doing a work requiring concentration. Sleep function is useful in cool and heat operation modes. Press the sleep button, the air flow sound from the indoor unit is decreased. Cool mode durin...

  • Page 20

    - 20 - programmed start (timer on) timer function timer on function allows to automatically start the air conditioner at your desired set time: when the air conditioner is in standby mode, press the timer button and the air conditioner will enter the timed switch-on mode. Repeatedly press the timer ...

  • Page 21

    - 21 - timer function programmed stop (timer off) timer off function allows to automatically stop the air conditioner at your desired set time: during the operation of the air conditioner, press the timer button and the air conditioner will enter the timed switch-off mode. Repeatedly press the timer...

  • Page 22

    - 22 - turbo operation turbo function turbo function allows to strengthen the capacity of the air conditioner. Turbo function is available in cool and heat modes. (it does not work in auto, dry and fan modes). Press turbo button during cool or heat operation, and fan speed will be automatically set ...

  • Page 23

    - 23 - 1) make sure the 2 batteries (“aaa” type, 1.5v) are fully charged and correctly fitted in the special slot on the remote controller, by respecting the polarity marked on the remote control itself. The average life of the batteries is about 1 year. 2) use the remote controller by turning it to...

  • Page 24

    - 24 - emergency operation emergency operation key to reach the emergency button, lift the frontal panel before. Opening the frontal panel: lightly push both sides of the frontal panel at the bottom and pull it to this side till a resistance is felt. Do not open the frontal panel at an angle over 60...

  • Page 25

    - 25 - adjusting the airflow direction adjusting the vertical airflow direction adjust the air direction properly to obtain a higher degree in comfort and to avoid harmful drafts. The vertical direction of the airflow can be set through the infrared remote control. Vertical airflow swinging operatio...

  • Page 26

    - 26 - adjusting the airflow direction adjusting the horizontal airflow direction (hked 511, 631 x models) horizontal airflow direction can be adjusted by remote controller. Vertical grille for adjusting left/right air flow direction swinging operation perform this setting while the air conditioner ...

  • Page 27

    - 27 - choose an adequate temperature setting: • when the air conditioner is operating in heating mode, avoid to set a too high temperature value. • when the air conditioner is operating in cooling mode, avoid to set a too low temperature value. Clean the air filters quite frequently: • to keep your...

  • Page 28

    - 28 - cleaning the air conditioner if the air filter screen is blocked by dust or dirt, the performance of cooling and heating will be affected, with the operation noise and power consumption increased. Therefore, the air filter screen should be cleaned regularly (every two weeks). To carry on the ...

  • Page 29

    - 29 - cleaning the air conditioner warning before starting the cleaning: 1 - stop the appliance by pressing on/off button on remote controller 2 - move the circuit breaker to “off” or “0” position 3 - pull the plug out of the power socket 4 - to reach the unit, please use a stepladder or other appr...

  • Page 30

    - 30 - ordinary maintenance at the beginning of season when restarting the air conditioner after a long time, or at the beginning of the season, please carry out the following procedure: do not obstruct the air inlet and outlet check if any objects obstruct the airflow at the air inlet and outlet on...

  • Page 31

    - 31 - ordinary maintenance at the end of season at the end of the season or in case you foresee not to use the air conditioner for a long time, please carry out the following procedure: dry the unit set the temperature at 30°c and operate the appliance in fan mode for half a day by setting a "high"...

  • Page 32

    - 32 - the following table shows a series of seeming malfunctions. Please check the following items before calling the authorized technical service. What happens reason after a stop, the air conditioner does not restarts immediately. (running indicator is illuminating). • restart is stopped for 3 mi...

  • Page 33

    - 33 - troubleshooting problems and possible solutions the following table shows a series of problems and their possible reasons and solutions. Please carry out the following checks before contacting the authorized technical service. The air conditioner does not operate at all. Poor cooling or heati...

  • Page 34

    - 34 - troubleshooting • you smell something burning. • obstacles or water enter the unit. • water leaks from indoor unit. • other malfunctions are observed (see the following table). Never try to repair the air conditioner by yourself caution ! If one of the following malfunctions occur, immediatel...

  • Page 35

    - 35 - malfunction codes check parts indoor unit display status the communication faults in the indoor and outdoor units. Code running lamp flashing times timer lamp flashing times serial number malfunction content indoor parts 1 2 f1 1 light indoor ambient temp. Sensor fault. F2 2 light 3 indoor co...

  • Page 36

    - 36 - protection codes check parts indoor unit display status evaporator temp. Protection. Code running lamp flashing times timer lamp flashing times serial number protection content indoor parts 1 p1 light 1 1 overheat, over current protection of inverter module. P2 light 2 2 over current protecti...

  • Page 37

    - 37 - • when a power failure occurs during operation, the air conditioner stops immediately. • when power is restored, the running lamp on the indoor unit lights up. • in particular, the air conditioner will restart automatically after 3 minutes have elapsed since power is restored. This means that...

  • Page 38: Notes

    Notes.

  • Page 39

    355 a 2.60 3.66 3.00 a 975 a 6.30 3.23 7.20 a hked 261 x hcnd 261 x (-1) hked 631 x hcnd 631 x (-1) 540 a 3.50 3.24 3.75 a hked 351 x hcnd 351 x (-1) 749 a 5.10 3.41 5.98 a hked 511 x hcnd 511 x (-1) m anufac tur er / c ostrutt or e / f abr ican t / f abr ican te / herst eller / f abr ik an t o ut d...

  • Page 40: Eslat As

    Due to on-going technological development of the products by the manufacturer, we reserve the right to vary the technical specifications at any time and without notice. Eslat as välja 35a, tallinn 10616, estonia tel.: (+372) 6 567 894 fax: (+372) 6 567 896 skype: eslat.As e-mail: info@eslat.Ee websi...