I3 International i3C760 Instruction Manual
• DESCRIPTION
User can use the control panel via RS-485 interface or
RS-422 interface to control the camera.The camera must
surport the PELCO P/D protocol and baud rate should be
1200/2400/4800/9600.
• PARTS' NAMES AND CONNECTIONS
BACK PANEL :
1. RS-232 FUNCTION
A personal computer can communicate with control panel
through DSUB 9 RS232 port,then via RS-485/RS-422 of
control panel,access of read/write of camera is possible.
Please read this manual thoroughly before use, and keep it handy for future reference
Control Panel
ZEIM-0050715G Ver.C.760.A.4
Instruction
Manual
1NC
6NC
2TX
7NC
3RX
8NC
4NC
9NC
5GND
DSUB-9 PINOUTS
5 4 3 2 1
SW5 Interface DIP
ON
RS-485
OFF RS-422
SW6 Turbo DIP
ON
ON
OFF OFF
SW3 Interface DIP
ON
Pelco D
OFF Pelco P
No Description
No Description
1
LED Display
9
Keypad (Numbers 0
through 9)
2
Shift LED
10 Near Key
3
Shift Key
11 Far Key
4
Pattern Key
12 Close Key
5
Preset Key
13 Open Key
6
Joystick
14 Zoom Out
7
Clear Key
15 Zoom In
8
Camera Selection Key
• PANEL FUNCTION
7 10 14 15
CAM
7
4
CLEAR
0
ZOOM OUT
8
9
5
6
NEAR
ZOOM IN
FAR
PRESET
PATTERN
1
3
2
OPEN
SHIFT
CLOSE
4 5 3 2 1
9
8
13
12
11
6
3.RJ45 PINOUTS ( RS485)
1.DATA+ 5.NC
2.DATA-
6.NC
3.NC
7.NC
4.NC
8.NC
4.RJ45 PINOUTS (RS-422)
1.TX+
5.GND
2.TX-
6.NC
3.12VAC /DC 7.RX-
4.Nonpolar
8.RX+
SW7 SW8
Buad Rate DIP 7 8
1
OFF
OFF
1200
2
ON
OFF
2400
3
OFF
ON
4800
4
ON
ON
9600
Notes: Need to reset power after switch setting.
2. SWITCH SETTINGS
Users can setup the prtocol and buad rate by using
DIP switch.The table below will provide DIP switch
information.
DIP SW
Description
SW1,2,4
MUST be OFF
SW3
Protocol setting
SW5
RS-422/ RS485 Select
SW6
Turbo ON/OFF
SW7~SW8
Baud Rate Select
1 2 3 4 5 6 7 8
RJ45 of the control panel