Ibertial EXPRESSION TWO Installation And Operation Manual - page 46
IBERITAL
Page 46
INSTALLATION AND OPERATION MANUAL
ENGLISH
1.2.- DIMENSIONS
DIMENSIONS
Model
No. Groups
Width (mm)
Height (mm) Length (mm)
IBERITAL INTENZ
1
585
415
476
2
585
415
790
3
585
415
964
IBERITAL IB7
1
508
460
445
2
508
460
695
540
( compact )
3
508
460
870
IBERITAL IB7 Portable
1
508
460
445
2
508
460
540
( compact )
NEW IBERITAL
2
568
455
783
3
568
455
953
IBERITAL EXPRESSION TWO
2
568
455
783
3
568
455
953
Important: Specifi cations may be subject to change without prior notice.
2.- INSTRUCTIONS FOR THE USER
2.1.- DESCRIPTION
1) Coff ee feed control buttons (CPU)
2) One-cup espresso feed
3) Two-cup espresso feed
4) Non-stop coff ee feed
5) One-cup coff ee feed
6) Two-cup coff ee feed
7) Steam tap
8) Hot water dispenser
9) Steam dispenser
10) Pump gauge
11) Boiler pressure gauge
12) Three-position switch
0 = OFF/STOP
1 = ON (Automatic fi lling connected)
2 = Control (Elements connected)
13) Red ON/OFF indicator light
14) Green ELEMENTS indicator light
15) Tray
16) Rating plate
17) Removable side panels
18) Hot water control knob
19) Hot water dosage
20) Feed button (automatic versions)
21) Filter holder
21a) Filter holder for one coff ee
21b) Filter holder for two coff ees
21c) Filter for one coff ee
21d) Filter for two coff ees
21e) Cleaning fi lter
22) Boiler water level viewer
23) Permanent thermo-magnetic switch
(Not included. Must be installed by a local authorized technician)
24) Mains water stopcock
(Not included. Must be installed by a local authorized technician)
25) Display
26) Drain valve
27) Deposit water inlet (Iberital IB7 Portable)
2.2.- PREPARATION AND START-UP
2.2.1. Stationary coff ee machines
a) Open the water stopcock (24).
b) Connect the permanent thermo-magnetic switch (23).
c) Machines with single boilers: Set the machine switch (12) to position 1 and wait until the automatic
level control completes the fi lling of the steam/hot water boiler with water.