    Ibm xseries 346 type 8840 user’s guide e rserver.

  • Page 3

    Ibm xseries 346 type 8840 user’s guide erserver.

  • Page 4

    Note: before using this information and the product it supports, read the general information in appendix b, “notices,” on page 39. Fifth edition (october 2005) © copyright international business machines corporation 2005. All rights reserved. Us government users restricted rights – use, duplication...

  • Page 5: Contents

    Contents safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . V chapter 1. Introducing the ibm xseries 346 type 8840 . . . . . . . . . 1 related documentation . . . . . . . . . . . . . . . . . . . . . . 1 notices and statements used in this document . . . . . . . . . . . . . . 2 features a...

  • Page 6

    Scsiselect utility menu choices . . . . . . . . . . . . . . . . . 36 appendix a. Getting help and technical assistance . . . . . . . . . . 37 before you call . . . . . . . . . . . . . . . . . . . . . . . . . 37 using the documentation . . . . . . . . . . . . . . . . . . . . . 37 getting help and inf...

  • Page 7: Safety

    Safety before installing this product, read the safety information. Antes de instalar este produto, leia as informações de segurança. Pred instalací tohoto produktu si prectete prírucku bezpecnostních instrukcí. Læs sikkerhedsforskrifterne, før du installerer dette produkt. Lees voordat u dit produc...

  • Page 8

    Läs säkerhetsinformationen innan du installerar den här produkten. Important: all caution and danger statements in this documentation begin with a number. This number is used to cross reference an english caution or danger statement with translated versions of the caution or danger statement in the ...

  • Page 9

    Statement 2 caution: when replacing the lithium battery, use only ibm part number 33f8354 or an equivalent type battery recommended by the manufacturer. If your system has a module containing a lithium battery, replace it only with the same module type made by the same manufacturer. The battery cont...

  • Page 10

    Statement 4 ≥ 18 kg (39.7 lb) ≥ 32 kg (70.5 lb) ≥ 55 kg (121.2 lb) caution: use safe practices when lifting. Statement 5 caution: the power-control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device. The device also might have ...

  • Page 11

    Statement 12 caution: the following label indicates a hot surface nearby. Statement 13 danger: overloading a branch circuit is potentially a fire hazard and a shock hazard under certain conditions. To avoid these hazards, ensure that your system electrical requirements do not exceed the branch circu...

  • Page 12

    Statement 16 caution: some accessory or option board outputs exceed class 2 or limited power source limits and must be installed with appropriate interconnecting cabling in accordance with the national electric code. Statement 17 caution: the following label indicates moving parts nearby. Warning: h...

  • Page 13: Chapter

    Chapter 1. Introducing the ibm xseries 346 type 8840 the ibm ® eserver ™ xseries ® 346 type 8840 server is a 2-u 1 -high server that can be upgraded to a symmetric multiprocessing (smp) server through a microprocessor upgrade. Performance, ease of use, reliability, and expansion capabilities were ke...

  • Page 14

    Depending on the server model, additional documentation might be included on the ibm xseries documentation cd. The server might have features that are not described in the documentation that you received with the server. The documentation might be updated occasionally to include information about th...

  • Page 15

    Features and specifications the following information is a summary of the features and specifications of the server. Depending on the server model, some features might not be available, or some specifications might not apply. Racks are marked in vertical increments of 1.75 inches. Each increment is ...

  • Page 16

    What your server offers the server uses the following features and technologies: v baseboard management controller the baseboard management controller provides environmental monitoring for the server. If environmental conditions exceed thresholds or if system components fail, the baseboard managemen...

  • Page 17

    V light path diagnostics light path diagnostics provides leds to help you diagnose problems. For more information, see the section about light path diagnostics in the installation guide . V redundant connection the addition of an optional network interface card (nic) provides a failover capability t...

  • Page 18

    V parity checking on the small computer system interface (scsi) bus and pci buses v power management: compliance with advanced configuration and power interface (acpi) v power-on self-test (post) v predictive failure analysis ® (pfa) alerts v redundant ethernet capabilities with failover support v r...

  • Page 19

    V reduced downtime v increased productivity of it personnel and users v reduced service and support costs for more information about ibm director, see the ibm director cd that comes with the server, the ibm director documentation on the cd, and the ibm xseries systems management web page at http://w...

  • Page 20

    Usb connector system-error led information led system-locator led scsi activity led power-control button power-on led release latch the following controls, leds, and connectors are on the operator information panel: v release latch: slide this latch to the left to access the light path diagnostics p...

  • Page 21

    Rear view the following illustration shows the connectors and leds on the rear of the server. Tx/rx tx/rx link link ethernet 2 ethernet 1 mouse universal serial bus (usb) serial video keyboard remote supervisor adapter ii ethernet slimline asm scsi system-locator led ethernet link status leds ethern...

  • Page 22

    Remote supervisor adapter ii slimline ethernet connector: use this connector to connect the server to a network for systems-management information control. This connector is active only if you have installed a remote supervisor adapter ii slimline. Usb connectors: connect usb devices to these connec...

  • Page 23

    Some operating systems require an orderly shutdown before you turn off the server. See your operating-system documentation for information about shutting down the operating system. Statement 5 caution: the power-control button on the device and the power switch on the power supply do not turn off th...

  • Page 24

    12 ibm xseries 346 type 8840: user’s guide.

  • Page 25: Chapter

    Chapter 2. Configuring the server the following configuration programs and capabilities come with your server: v configuration/setup utility the configuration/setup utility program is part of the basic input/output system (bios) code in your server. Use it to configure serial port assignments, chang...

  • Page 26

    V set and change settings for advanced hardware features v view and clear error logs starting the configuration/setup utility program complete the following steps to start the configuration/setup utility program: 1. Turn on the server. 2. When the prompt press f1 for configuration/setup appears, pre...

  • Page 27

    This choice is on the full configuration/setup utility menu only. V system security select this choice to set passwords. See “passwords” on page 17 for more information about passwords. This choice is on the full configuration/setup utility menu only. – power-on password select this choice to set or...

  • Page 28

    Manually enable the memory connectors. Use the arrow keys to highlight the pair of memory connectors that you want to enable, and use the arrow keys to select enable . Select memory configuration to enable memory mirroring or online-spare memory. You can enable either online-spare memory or memory m...

  • Page 29

    Passwords from the system security choice, you can set, change, and delete a power-on password and an administrator password. The system security choice is on the full configuration/setup menu only. If you set only a power-on password, you must type the power-on password to complete the system start...

  • Page 30

    Administrator password if an administrator password is set, you must type the administrator password for access to the full configuration/setup utility menu. You can use any combination of up to seven characters (a–z, a–z, and 0–9) for the password. The administrator password choice is on the config...

  • Page 31

    V detects the scsi raid adapter, controller, or integrated scsi controller with raid capabilities and runs the scsi raid configuration program (with lsi chip sets for serveraid adapters only) v checks the microcode (firmware) levels of a serveraid adapter and determines whether a later level is avai...

  • Page 32

    Installing your operating system without serverguide if you have already configured the server hardware and you decide not to use the serverguide program to install your operating system, complete the following steps to download the latest operating-system installation instructions from the ibm supp...

  • Page 33

    Note: you must have at least two hard disk drives installed in the server to configure a raid level-0 array. 1. From the scsiselect utility main menu, select configure/view hostraid settings . 2. From the list of ready drives, type c to create an array. 3. Select raid-0 when asked to select the raid...

  • Page 34

    Configuration method described in the instructions that come with that adapter to view or change scsi settings for attached devices. See the documentation on the serveraid-7e (adaptec hostraid) support cd for additional information about how to use the scsi hostraid feature. Configuring the controll...

  • Page 35

    1000base-t) and duplex mode (full-duplex or half-duplex) of the network and automatically operate at that rate and mode. You do not have to set any jumpers or configure the controllers. However, you must install a device driver to enable the operating system to address the controllers. For device dr...

  • Page 36

    A. Restart the server and press f1 when prompted to start the configuration/setup utility program. B. Select devices and i/o ports ; then, make sure that the values are set as follows: v serial port a : auto-configure v serial port b : auto-configure c. Select remote console redirection ; then, make...

  • Page 37

    Note: this procedure is based on a default installation of red hat enterprise linux es 2.1. The file names, structures, and commands might be different for other versions of red hat linux. Complete the following steps to configure the general linux parameters for sol operation when using the red hat...

  • Page 38

    Original /etc/lilo.Conf contents prompt timeout=50 default=linux boot=/dev/hda map=/boot/map install=/boot/boot.B message=/boot/message linear image=/boot/vmlinuz-2.4.9-e.12smp label=linux initrd=/boot/initrd-2.4.9-e.12smp.Img read-only root=/dev/hda6 image=/boot/vmlinuz-2.4.9-e.12 label=linux-up in...

  • Page 39

    Modified /etc/lilo.Conf contents prompt timeout=50 default=linux-monitor boot=/dev/hda #map=/boot/map install=/boot/boot.B #message=/boot/message linear # this will allow you to only monitor the os boot via sol image=/boot/vmlinuz-2.4.9-e.12smp label=linux-monitor initrd=/boot/initrd-2.4.9-e.12smp.I...

  • Page 40

    Kernel /vmlinuz-2.4.9-e.12smp ro root=/dev/hda6 console=tty1 console=ttys0,19200 initrd /initrd-2.4.9-e.12smp.Img note: the entry that begins with kernel /vmlinuz is shown with a line break after console=tty1 . In your file, the entire entry must all be on one line. The following examples show the o...

  • Page 41

    Modified /boot/grub/grub.Conf contents #grub.Conf generated by anaconda # # note that you do not have to rerun grub after making changes to this file # notice: you have a /boot partition. This means that # all kernel and initrd paths are relative to /boot/, eg. # root (hd0,0) # kernel /vmlinuz-versi...

  • Page 42

    A. Comment out the gfxmenu line by adding a # in front of the word gfxmenu . B. Add the following line before the first title line: # this will allow you to only monitor the os boot via sol c. Append the following text to the first title line: sol monitor d. Append the following text to the kernel l...

  • Page 43

    Modified /boot/grub/menu.Lst contents notes root chainloader +1 title failsafe kernel (hd0,1)/boot/vmlinuz.Shipped root=/dev/hda2 ide=nodma apm=off vga=normal nosmp 1 disableapic maxcpus=0 3 initrd (hd0,1)/boot/initrd.Shipped note 1: the kernel line is shown with a line break. In your file, the enti...

  • Page 44

    Original bootcfg program output boot loader settings ---------------------------- timeout: 30 default: multi(0)disk(0)rdisk(0)partition(1)\windows boot entries ---------------- boot entry id: 1 os friendly name: windows server 2003, standard path: multi(0)disk(0)rdisk(0)partition(1)\windows os load ...

  • Page 45

    3. Follow the prompts to complete the installation. The installation program prompts you for a tcp/ip port number and an ip address. Specify an ip address, if you want to limit the connection requests that will be accepted by the utility program. To accept connections from any server, type inaddr_an...

  • Page 46

    The utility starts automatically when the server is started. You can also locate the /ect/init.D directory to start the utility and use the following commands to manage the utility: smbridge status smbridge start smbridge stop smbridge restart using the baseboard management controller utility progra...

  • Page 47

    Use the following commands in cli mode: – identify control the system-locator led on the front of the server. – power turn the server on and off remotely. – sel perform operations with the system event/error log. – sysinfo display general system information that is related to the server and the base...

  • Page 48

    5. Use the arrow keys to select a choice from the menu. 6. Follow the instructions on the screen to change the settings of the selected items, and press enter. Scsiselect utility menu choices the following choices are on the scsiselect utility menu: v configure/view scsi controller settings select t...

  • Page 49: Appendix

    Appendix a. Getting help and technical assistance if you need help, service, or technical assistance or just want more information about ibm products, you will find a wide variety of sources available from ibm to assist you. This appendix contains information about where to go for additional informa...

  • Page 50

    Getting help and information from the world wide web on the world wide web, the ibm web site has up-to-date information about ibm eserver and intellistation systems, optional devices, services, and support. The address for ibm xseries and bladecenter ® information is http://www.Ibm.Com/eserver/xseri...

  • Page 51: Appendix

    Appendix b. Notices this information was developed for products and services offered in the u.S.A. Ibm may not offer the products, services, or features discussed in this document in other countries. Consult your local ibm representative for information on the products and services currently availab...

  • Page 52

    Trademarks the following terms are trademarks of international business machines corporation in the united states, other countries, or both: active memory ibm (logo) tivoli active pci intellistation tivoli enterprise active pci-x netbay update connector alert on lan netfinity wake on lan bladecenter...

  • Page 53

    When referring to hard disk drive capacity or communications volume, mb stands for 1 000 000 bytes, and gb stands for 1 000 000 000 bytes. Total user-accessible capacity may vary depending on operating environments. Maximum internal hard disk drive capacities assume the replacement of any standard h...

  • Page 54

    Remarque : cette marque s’applique uniquement aux pays de l’union européenne et à la norvège. L’etiquette du système respecte la directive européenne 2002/96/ec en matière de déchets des equipements electriques et electroniques (deee), qui détermine les dispositions de retour et de recyclage applica...

  • Page 55

    Electronic emission notices federal communications commission (fcc) statement note: this equipment has been tested and found to comply with the limits for a class a digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interf...

  • Page 56

    55022. The limits for class a equipment were derived for commercial and industrial environments to provide reasonable protection against interference with licensed communication equipment. Attention: this is a class a product. In a domestic environment this product may cause radio interference in wh...

  • Page 57: Index

    Index a ac power led 9 acoustical noise emissions 3 active memory 4 attention notices 2 availability 5 b baseboard management controller 4 baseboard management controller utility programs 34 c caution statements 2 class a electronic emission notice 43 command-line interface commands identify 35 powe...

  • Page 58

    Notices electronic emission 43 fcc, class a 43 notices and statements 2 o online publications 2 operator information panel 7 osa smbridge management utility program enabling and configuring 23 installing 32 p pci expansion slots 3 power supply specifications 3 power-control button 8 power-control-bu...

  • Page 60

    Part number: 31r1192 printed in usa (1p) p/n: 31r1192.