IBM DU3 2104 Hardware Technical Information

Other manuals for DU3 2104: Operator's Manual
Manual is about: Expandable Storage Plus

Summary of DU3 2104

  • Page 1

    Expandable storage plus 2104 models du3 and tu3 hardware technical information sa33-3309-00

  • Page 3

    Expandable storage plus 2104 models du3 and tu3 hardware technical information sa33-3309-00

  • Page 4

    First edition (october 2000) the following paragraph does not apply to any country where such provisions are inconsistent with local law: this publication is printed “as is” without warranty of any kind, either express or implied, including, but not limited to, the implied warranties of merchantabil...

  • Page 5: Contents

    Contents about this book . . . . . . . . . . . . . . . . . . . . . . . V related publications . . . . . . . . . . . . . . . . . . . . . . V trademarks . . . . . . . . . . . . . . . . . . . . . . . . V chapter 1. Introduction . . . . . . . . . . . . . . . . . . . . . 1 2104 model du3 . . . . . . . . ...

  • Page 6

    Mainline-power connectors . . . . . . . . . . . . . . . . . . . 26 iv 2104 models du3 and tu3 hardware technical information.

  • Page 7: About This Book

    About this book this book is intended for system designers, programmers, engineers, and other professionals who need to understand the 2104 models du3 and tu3. Chapter 1 contains an introduction and general information about the components of the 2104 models du3 and tu3. Chapter 2 contains a summary...

  • Page 8

    Vi 2104 models du3 and tu3 hardware technical information.

  • Page 9: Chapter 1. Introduction

    Chapter 1. Introduction this section describes the 2104 models du3 and tu3 and their components. Figure 1. 2104 model tu3 (on the left) and 2104 model du3 (on the right) 1.

  • Page 10

    2104 model du3 the 2104 model du3 is a rack-mounted scsi disk enclosure that can be attached to any rs/6000 or ibm ™ server tm ™ pseries computer that provides support for any of the small computer system interface (scsi) adapters listed in “scsi adapters and cables” on page 25. A fully configured 2...

  • Page 11

    On the back of the backplane are connectors for two fan-and-power-supply assemblies 3 , two scsi interface cards 4 , and a switch card 5 . The 2104 model du3 has either two fan-and-power-supply assemblies or one fan-and-power-supply assembly and one fan assembly. Either option provides all the neces...

  • Page 12

    2104 model tu3 the 2104 model tu3 is a deskside scsi disk enclosure that can be attached to any rs/6000 or ibm server pseries computer that provides support for any of the small computer system interface (scsi) adapters listed in “scsi adapters and cables” on page 25. A fully configured 2104 model t...

  • Page 13

    The 2104 model tu3 can have either two fan-and-power-supply assemblies or one fan-and-power-supply assembly and one fan assembly. Either option provides all the necessary power and cooling for the 2104 model tu3. The scsi interface cards are used to connect host machines to the 2104 model tu3. These...

  • Page 14

    Scsi disk drive modules each 2104 model du3 or tu3 includes from one to fourteen scsi disk drive modules. In your initial order, you can select the capacity of these disk drive modules. Each disk slot contains either a disk drive module or a dummy module. You can replace any dummy module with a disk...

  • Page 15

    Scsi interface cards attached to the back of the backplane in a fully configured 2104 model du3 or 2104 model tu3 are two scsi interface cards. Both cards can be used to connect host machines to the 2104 disk enclosure. A scsi interface card provides the following functions: v supports scsi enclosur...

  • Page 16

    Fan-and-power-supply assemblies attached to the back of the backplane in a fully configured 2104 model du3 or 2104 model tu3 are two fan-and-power-supply assemblies. Each fan-and-power-supply assembly provides enough power for the 2104, so it is possible for there to be just one fan-and-power-supply...

  • Page 17

    Switch card attached to the back of the backplane in a fully configured 2104 model du3 or 2104 model tu3, the switch card contains switches that control some of the functions of the 2104. Switches that are accessible from the back of the 2104 are provided to indicate: v whether power to the 2104 is ...

  • Page 18

    Scsi bus bridge card located centrally in the front of a 2104 model du3 or 2104 model tu3, the scsi bus bridge card controls the scsi bus configuration of the 2104. It assigns the disk drive modules to a scsi bus, in accordance with the setting of the scsi bus split switch on the switch card. Scsi b...

  • Page 19

    Notes: 1. The two host bus adapters cannot have the same scsi address. 2. Disk drive slots 6 and 7 (scsi ids 5 and 6) have dummy disk drive modules installed in them. Note: in this configuration, scsi addresses 5 and 6 cannot be used for disk drive modules. Terminator terminator backplane terminator...

  • Page 20

    Terminator terminator backplane terminator terminator scsi interface card scsi interface card host bus adapter (hba) id:7 host bus adapter (hba) id:7 terminators 7 disk drive modules 7 disk drive modules repeater repeater enclosure service processor scsi bus bridge card enclosure service processor r...

  • Page 21

    Chapter 2. Product characteristics this section describes the physical characteristics of the 2104 model du3 and 2104 model tu3, and their environmental and power requirements. Dimensions model height width depth model du3 128 mm (5.0 in.) 3 eia units 445 mm (18 in.) 552 mm max (22 in.) model tu3 52...

  • Page 22

    Environment temperature and humidity a 2104 has the following environmental limits: air temperature relative humidity maximum wet bulb operating 10°c to 40°c (50°f to 104°f) 8% to 80% noncondensing 27°c (80°f) recommended operating point 22°c (72°f) 45% recommended operating range 20°c to 25°c (68°f...

  • Page 23

    Heat output, airflow, and cooling the maximum heat output of either model is 330 watts (1126 btu/hr). Each 2104 requires an airflow of 1.1 m ³ ( 40 cubic feet) per minute. When racks containing many 2104s are to be installed together, the following requirements must be met to ensure that the 2104s a...

  • Page 24

    Electrical power electrical power is supplied to each 2104 by either one or two fan-and-power-supply assemblies. These fan-and-power-supply assemblies convert the input voltage to dc for distribution within the 2104. One fan-and-power-supply assembly provides enough power for a fully populated 2104....

  • Page 25

    Description operating (100 disk ops per second) two power supplies (100 disk ops per second) 100 vac input 410 w 210 w each 240 vac input 430 w 220 w each power factor power factor correction is applied within the fan-and-power-supply assemblies of each 2104. This maintains the power factor of the u...

  • Page 26

    Power control each fan-and-power-supply assembly in the 2104 has a dc on/standby switch. The power to the 2104 is also controlled by the power control switch on the switch card. Power sequencing the power sequencing of the disk drive modules in a 2104 is controlled by the settings of the drive auto-...

  • Page 27

    Safety approvals a 2104 model du3 or tu3 is certified to the following safety standards: v iec 60950 (international electrotechnical commission) v en 60950 (european nom) v csa950/ul1950 binational (csa underwriters laboratories’ binational ite standard) chapter 2. Product characteristics 19.

  • Page 28

    Electromagnetic compatibility federal communications commission (fcc) statement this equipment has been tested and found to comply with the limits for a class a digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interferen...

  • Page 29

    Industry canada compliance statement this class a digital apparatus complies with iecs-003. United kingdom telecommunications requirements this apparatus is manufactured to the international safety standard en60950 and as such is approved in the u.K. Under approval number ns/g/1234/j/100003 for indi...

  • Page 30

    Taiwan class a compliance statement 22 2104 models du3 and tu3 hardware technical information.

  • Page 31

    Chapter 3. Physical connections figure 7 shows the external connectors of the 2104 model du3. 1 are scsi connectors and 2 are mainline power connectors. Figure 7. Back of a 2104 model du3 showing external connectors 23.

  • Page 32

    Figure 8 shows the external connectors of the 2104 model tu3. 1 are mainline power connectors and 2 are scsi connectors. This section provides information about these connectors. Figure 8. Back of a 2104 model tu3 showing external connectors 24 2104 models du3 and tu3 hardware technical information.

  • Page 33

    Scsi adapters and cables an rs/6000 or ibm server pseries computer uses one of the following scsi adapters to connect to the 2104 model du3 or 2104 model tu3: v pci 3-channel ultra2 scsi raid adapter (feature code 2494 type number 4-t) v pci dual channel ultra2 scsi adapter (feature code 6205 type n...

  • Page 34

    Mainline-power connectors main ac power supply on a 2104 model du3 or 2104 model tu3 a mainline-power connector is on each fan-and-power-supply assembly. The connector is a 10-amp, three-pin, polarized, iec 320 input connector. See figure 9, in which 1 is the ground connection, 2 is the neutral conn...

  • Page 36

    Part number: 07k8063 printed in the u.S.A. Sa33-3309-00 (1p) p/n: 07k8063.