IBM Netfinity 4500R Installation Manual

Other manuals for Netfinity 4500R: Hardware Maintenance Manual, User Reference Manual

Summary of Netfinity 4500R

  • Page 1

    Ibm ibm ® netfinity ® 4500r installation guide sc09-n819-30

  • Page 2

    Note before using this information and the product it supports, be sure to read the general information in “appendix a. Product warranties and notices,” on page 31. First edition (march 2000) © copyright international business machines corporation, 2000. All rights reserved. Note to u.S. Government ...

  • Page 3: Contents

    Contents safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V chapter 1.Introduction . . . . . . . . . . . . . . . . 1 specifications and features. . . . . . . . . . . . . . . . . . . . . . . . . 2 notices used in this book . . . . . . . . . . . . . . . . . . . . . . . . . . 3 major co...

  • Page 4

    Ibm® netfinity® 4500r installation guide.

  • Page 5: Safety

    © copyright ibm corp. 2000 v safety safety before installing this product, read the safety information book. Antes de instalar este produto, leia o manual de informações sobre segurança. Læs hæftet med sikkerhedsforskrifter, før du installerer dette produkt. Lue safety information -kirjanen, ennen k...

  • Page 6

    Vi ibm® netfinity® 4500r installation guide safety lees voordat u dit product installeert eerst het boekje met veiligheidsvoorschriften. Les heftet om sikkerhetsinformasjon (safety information) før du installerer dette produktet. Antes de instalar este produto, leia o folheto informações sobre segur...

  • Page 7

    Vii safety statement 1 danger electrical current from power, telephone, and communication cables is hazardous. To avoid a shock hazard: • do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm. • connect all power c...

  • Page 8

    Viii ibm® netfinity® 4500r installation guide safety statement 2 caution: when replacing the lithium battery, use only ibm part number 33f8354 or an equivalent type battery recommended by the manufacturer. If your system has a module containing a lithium battery, replace it only with the same module...

  • Page 9

    Ix safety statement 4 ≥ 18 kg (37 lbs) ≥ 32 kg (70.5 lbs) ≥ 55 kg (121.2 lbs) caution: use safe practices when lifting. Statement 5 caution: the power control button on the device and the power supply do not turn off the electrical current supplied to the device. The device also might have more than...

  • Page 10

    X ibm® netfinity® 4500r installation guide safety.

  • Page 11: Chapter 1. Introduction

    © copyright ibm corp. 2000 1 chapter 1. Introduction introduct ion thank you for purchasing an ibm® netfinity® 4500r server. This installation guide provides the information needed to: • set up and cable your server • start and configure your server • install your network operating system (nos) pack...

  • Page 12

    2 ibm® netfinity® 4500r installation guide specifications and features specifications and features specific ations a nd featu res the following table provides a summary of the features and specifications for your netfinity 4500r server. Microprocessor: • intel® pentium® iii • 256 kb level-2 cache • ...

  • Page 13

    Chapter 1. Introduction 3 notices used in this book notices used in this book notices used i n this book this information product contains notices that relate to a specific topic. The caution and danger notices also appear in the multilingual safety booklet that came with your netfinity product. Eac...

  • Page 14

    4 ibm® netfinity® 4500r installation guide major components major components of the netfinity 4500r server major co mponents the orange color on components and labels in your server identifies hot-swap or hot- plug components. This means that you can install or remove the components while the system...

  • Page 15

    © copyright ibm corp. 2000 5 chapter 2. Installing options this chapter provides the basic information needed to install hardware options in your server. This section is for all users, but is written with the experienced user in mind. If you need more detailed installation information, refer to the ...

  • Page 16

    6 ibm® netfinity® 4500r installation guide installing adapters the following illustration shows the location of the pci expansion slots on the system board. Note: the illustrations in this document might differ slightly from your hardware. Pci slot 5 64-bit 33 mhz (j44) pci slot 4 64-bit 33 mhz (j39...

  • Page 17

    Chapter 2. Installing options 7 installing adapters the following illustration shows the installation of an adapter. To install an adapter: attention: when you handle electrostatic discharge-sensitive devices (esd), take precautions to avoid damage from static electricity. For details on handling th...

  • Page 18

    8 ibm® netfinity® 4500r installation guide installing adapters the following illustration shows the rerouting of the scsi cable if you install an ibm serveraid adapter. 1. Disconnect the cable from scsi connector b on the system board. 2. Connect the cable to the connector on the serveraid adapter. ...

  • Page 19

    Chapter 2. Installing options 9 installing a drive in a hot-swap bay installing a drive in a hot-swap bay install ing a d rive in a hot- swap bay your server supports three 1-inch (26 mm) slim-high hot-swap hard disk drives in the hot-swap bays. Note: refer to the user’s reference on the ibm netfini...

  • Page 20

    10 ibm® netfinity® 4500r installation guide installing a microprocessor installing a microprocessor installi ng a mic roproces sor your server comes with one microprocessor installed in the microprocessor connector that is farther away from the memory slots (connector u3). This is the startup (boot)...

  • Page 21

    Chapter 2. Installing options 11 installing a microprocessor to install an additional microprocessor: attention: when you handle electrostatic discharge-sensitive devices (esd), take precautions to avoid damage from static electricity. For details on handling these devices, refer to the following we...

  • Page 22

    12 ibm® netfinity® 4500r installation guide installing a hot-swap power supply installing a hot-swap power supply install ing a ho t-swap p ower sup ply if you install or remove a power supply, observe the following precaution. Statement 8 caution: never remove the cover on a power supply or any par...

  • Page 23

    Chapter 2. Installing options 13 installing a hot-swap power supply refer to the following illustrations to install an additional power supply. Note: the illustrations in this document might differ slightly from your hardware. To install a power supply: 1. Remove the filler panel. Note: during norma...

  • Page 24

    14 ibm® netfinity® 4500r installation guide installing memory-module kits installing memory modules installi ng memory- module k its before you install memory, review the following: • your server comes with a dual inline memory module (dimm) installed in dimm connector 1 (j23). Install additional di...

  • Page 25

    Chapter 2. Installing options 15 cabling the server cabling the server cabling the serv er the following illustrations show the connectors on the rear of the server and cable routing for the server. Note: the illustrations in this document might differ slightly from your hardware. Mouse advanced sys...

  • Page 26

    16 ibm® netfinity® 4500r installation guide cabling the server.

  • Page 27

    © copyright ibm corp. 2000 17 chapter 3. Starting the server use the following procedure to start your server. 1. Turn on all external devices, such as the monitor. Note: after you plug the power cord into an outlet, wait 20 seconds before pressing the power control button. During this time, the pow...

  • Page 28

    18 ibm® netfinity® 4500r installation guide controls and indicators time the system-management processor is initializing and the power control button does not respond. • if the server is turned on, a power failure occurs, and unattended-start mode is enabled in the configuration/setup utility progra...

  • Page 29

    Chapter 3. Starting the server 19 controls and indicators ac power light: this green light provides status information about the power supply. During normal operation, both the ac and dc power lights are on. For information about any other combination of lights, refer to the user’s reference on the ...

  • Page 30

    20 ibm® netfinity® 4500r installation guide operator information panel operator information panel operator informat ion panel the following illustration shows the operator information panel on the front of the server. (see “controls and indicators” on page 17 for the location of the operator informa...

  • Page 31

    © copyright ibm corp. 2000 21 chapter 4. Configuring your server configur ing your server the serverguide cds provide software setup tools and installation tools that are specifically designed for your ibm netfinity server. Use these cds during the initial installation of your server to configure ba...

  • Page 32

    22 ibm® netfinity® 4500r installation guide netfinity system management solutions after installing the nos be sure to take advantage of the following additional software that is included with the serverguide package: • operating system updates cds — include selected nos updates that are provided by ...

  • Page 33

    © copyright ibm corp. 2000 23 chapter 5. Solving problems solving problems this section provides basic troubleshooting information to help you resolve some common problems that might occur while setting up your server. If you cannot locate and correct the problem using the information in this sectio...

  • Page 34

    24 ibm® netfinity® 4500r installation guide post error messages post error messages post er ror mess ages the following table provides an abbreviated list of the error messages that might appear during post. Note: see the "solving problems" section of the user’s reference on the ibm netfinity docume...

  • Page 35

    Chapter 5. Solving problems 25 post error messages post message failing device or problem found suggested action 129 l1 cache of a microprocessor check the installation of your microprocessors. 162 change in device configuration verify that your optional devices are turned on and installed correctly...

  • Page 36

    26 ibm® netfinity® 4500r installation guide serverguide startup problems serverguide startup problems servergui de start up probl ems look for the symptom in the left column of the chart. Probable solutions to the problem are in the right column. Setup suggested action netfinity setup and installati...

  • Page 37

    Chapter 5. Solving problems 27 troubleshooting chart troubleshooting chart troubles hooting chart notes: 1. Refer to the "solving problems" section of the user’s reference on the ibm netfinity documentation cd for more detailed troubleshooting charts. 2. If you cannot find the problem in the trouble...

  • Page 38

    28 ibm® netfinity® 4500r installation guide troubleshooting chart power problems suggested action the server does not power on. Verify that: 1. The power cables are properly connected to the server. 2. The electrical outlet functions properly. 3. The type of memory that is installed is correct. 4. I...

  • Page 39

    Chapter 5. Solving problems 29 troubleshooting chart option problems suggested action an ibm option that was just installed does not work. Verify that: 1. The server supports the option. Refer to the "support for netfinity servers" flowchart for information about obtaining serverproven™ compatibilit...

  • Page 40

    30 ibm® netfinity® 4500r installation guide troubleshooting chart.

  • Page 41

    © copyright ibm corp. 2000 31 appendix a. Product warranties and notices this chapter contains warranty and emission notices. It also contains trademarks and general-information notices. Warranty statements the warranty statements consist of two parts: part 1 and part 2. Part 1 varies by country. Pa...

  • Page 42

    32 ibm® netfinity® 4500r installation guide during the warranty period ibm or your reseller, if approved by ibm to provide warranty service, will provide repair and exchange service for the machine, without charge, under the type of service designated for the machine and will manage and install engi...

  • Page 43

    Appendix a. Product warranties and notices 33 upgrade. Many features, conversions, or upgrades involve the removal of parts and their return to ibm. A part that replaces a removed part will assume the warranty service status of the removed part. Before ibm or your reseller exchanges a machine or par...

  • Page 44

    34 ibm® netfinity® 4500r installation guide some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Ibm statement of warranty worldwide except canada, puerto rico, turkey, united states (part 1 – g...

  • Page 45

    Appendix a. Product warranties and notices 35 conditions of merchantability and fitness for a particular purpose. These warranties give you specific legal rights and you may also have other rights which vary from jurisdiction to jurisdiction. Some jurisdictions do not allow the exclusion or limitati...

  • Page 46

    36 ibm® netfinity® 4500r installation guide ibm is responsible for loss of, or damage to, your machine while it is 1) in ibm’s possession or 2) in transit in those cases where ibm is responsible for the transportation charges. Neither ibm nor your reseller is responsible for any of your confidential...

  • Page 47

    Appendix a. Product warranties and notices 37 limitation of liability: the following is added to this section: where ibm is in breach of a condition or warranty implied by the trade practices act 1974, ibm’s liability is limited to the repair or replacement of the goods or the supply of equivalent g...

  • Page 48

    38 ibm® netfinity® 4500r installation guide the laws of austria govern this statement if the warranty service is provided in albania, armenia, belarus, bosnia and herzegovina, bulgaria, croatia, czech republic, federal republic of yugoslavia, georgia, hungary, kazakhstan, kirghizia, former yugoslav ...

  • Page 49

    Appendix a. Product warranties and notices 39 greater of irish pounds 75,000 or 125 percent of the charges (if recurring, the 12 months’ charges apply) for the machine that is the subject of the claim or which otherwise gives rise to the claim. Applicability of suppliers and resellers (unchanged). T...

  • Page 50

    40 ibm® netfinity® 4500r installation guide notices references in this publication to ibm products, programs, or services do not imply that ibm intends to make these available in all countries in which ibm operates. Any reference to an ibm product, program, or service is not intended to state or imp...

  • Page 51

    Appendix a. Product warranties and notices 41 note to u.S. Government users — documentation related to restricted rights — use, duplication or disclosure is subject to restrictions set forth in gsa adp schedule contract with ibm corp. Year 2000 readiness and instructions this is a year 2000 readines...

  • Page 52

    42 ibm® netfinity® 4500r installation guide lotus and domino are trademarks of lotus development corporation in the united states, other countries, or both. Tivoli and netview are trademarks of tivoli systems inc. In the united states, other countries, or both. Intel, mmx, landesk, pentium, pentium ...

  • Page 53

    Appendix a. Product warranties and notices 43 properly shielded and grounded cables and connectors must be used in order to meet fcc emission limits. Ibm is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized change...

  • Page 54

    44 ibm® netfinity® 4500r installation guide taiwan electrical emission statement japanese voluntary control council for interference (vcci) statement power cords for your safety, ibm provides a power cord with a grounded attachment plug to use with this ibm product. To avoid electrical shock, always...

  • Page 55

    Appendix a. Product warranties and notices 45 ibm power cord part number used in these countries and regions 13f9940 argentina, australia, china (prc), new zealand, papua new guinea, paraguay, uruguay, western samoa 13f9979 afghanistan, algeria, andorra, angola, austria, belgium, benin, bulgaria, bu...

  • Page 56

    46 ibm® netfinity® 4500r installation guide.

  • Page 57: Index

    47 index a ac power light 19 acoustical noise emissions 2 adapters 5 b beep codes 23 c cabling external 15 power supply 13 serveraid adapter 8 cd-rom drive 2 class a electronic emission notice 42 components color 4 major 4 configuration/setup utility pro- gram 5 , 21 configuring your server 21 conne...

  • Page 58

    48 ibm® netfinity® 4500r installation guide.

  • Page 60

    Ibm part number: 09n8193 printed in the united states of america on recycled paper containing 10& recovered post-consumer fiber. Sc09-n819-30 *07sc09n81930* 09n8193 0409n8193.