  • Page 1

    Ibm ibm ® netfinity ® 6000r installation guide sc09-n820-30

  • Page 3

    Ibm ibm ® netfinity ® 6000r installation guide.

  • Page 4

    Note before using this information and the product it supports, be sure to read the general information in “appendix a. Product warranties and notices,” on page 35. First edition (march 2000) © copyright international business machines corporation, 2000. All rights reserved. Note to u.S. Government ...

  • Page 5: Contents

    Contents safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V chapter 1.Introduction . . . . . . . . . . . . . . . . 1 specifications and features . . . . . . . . . . . . . . . . . . . . . . . . 2 notices used in this book . . . . . . . . . . . . . . . . . . . . . . . . . . 3 major com...

  • Page 6

    Ibm® netfinity® 6000r installation guide.

  • Page 7: Safety

    © copyright ibm corp. 2000 v safety before installing this product, read the safety information book. Antes de instalar este produto, leia o manual de informações sobre segurança. Læs hæftet med sikkerhedsforskrifter, før du installerer dette produkt. Lue safety information -kirjanen, ennen kuin ase...

  • Page 8

    Vi ibm® netfinity® 6000r installation guide lees voordat u dit product installeert eerst het boekje met veiligheidsvoorschriften. Les heftet om sikkerhetsinformasjon (safety information) før du installerer dette produktet. Antes de instalar este produto, leia o folheto informações sobre segurança. A...

  • Page 9

    Vii statement 1 danger electrical current from power, telephone, and communication cables is hazardous. To avoid a shock hazard: • do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm. • connect all power cords to...

  • Page 10

    Viii ibm® netfinity® 6000r installation guide statement 2 caution: when replacing the lithium battery, use only ibm part number 33f8354 or an equivalent type battery recommended by the manufacturer. If your system has a module containing a lithium battery, replace it only with the same module type m...

  • Page 11

    Ix statement 4 ≥ 18 kg (37 lbs) ≥ 32 kg (70.5 lbs) ≥ 55 kg (121.2 lbs) caution: use safe practices when lifting..

  • Page 12

    X ibm® netfinity® 6000r installation guide statement 5 caution: the power control button on the device and the power supply do not turn off the electrical current supplied to the device. The device also might have more than one power cord. To remove all electrical current from the device, ensure tha...

  • Page 13: Chapter 1. Introduction

    © copyright ibm corp. 2000 1 chapter 1. Introduction thank you for purchasing an ibm® netfinity® 6000r server. This installation guide provides the information needed to: • set up and cable your server • start and configure your server • install your network operating system (nos) packaged with this...

  • Page 14

    2 ibm® netfinity® 6000r installation guide specifications and features the following table provides a summary of the features and specifications for your netfinity 6000r server. Microprocessor: • intel® pentium® iii xeon™ • 32 kb level-1 cache • 1 mb level-2 cache (min.) • 100 mhz front-side bus (fs...

  • Page 15

    Chapter 1. Introduction 3 notices used in this book this information product contains notices that relate to a specific topic. The caution and danger notices also appear in the multilingual safety booklet that came with your netfinity product. Each notice is numbered for easy reference to the corres...

  • Page 16

    4 ibm® netfinity® 6000r installation guide major components of the netfinity 6000r server the orange color on components and labels in your server identifies hot-swap or hot- plug components. This means that you can install or remove the components while the system is running, provided that your sys...

  • Page 17

    Chapter 1. Introduction 5 terminator card microprocessor hot-swap drive tray assembly filler panel for hot-swap drive tray filler panel for power supply bay power supply hot-swap fans hot-swap fans memory board dual inline memory module (dimm) netfinity advanced system management interconnect board ...

  • Page 18

    6 ibm® netfinity® 6000r installation guide.

  • Page 19

    © copyright ibm corp. 2000 7 chapter 2. Installing options this chapter provides the basic information needed to install options in your server. This section is for all users, but is written with the experienced user in mind. If you need more detailed installation information, see the user’s referen...

  • Page 20

    8 ibm® netfinity® 6000r installation guide installing adapters this section describes how to install hot-plug pci adapters. Before you continue with the adapter-installation procedure, review the following: • slot 1 supports hot-plug, 32-bit, 33-mhz, pci adapters. • slots 2-4 support hot-plug, 64-bi...

  • Page 21

    Chapter 2. Installing options 9 the following illustration shows the installation of a hot-plug adapter. Attention: when you handle electrostatic discharge-sensitive devices (esd), take precautions to avoid damage from static electricity. For details on handling these devices, refer to the following...

  • Page 22

    10 ibm® netfinity® 6000r installation guide the following illustration shows the rerouting of the scsi cable, if you install an ibm serveraid® adapter. To cable an ibm serveraid adapter: 1. Review the information in “safety” on page v. 2. Turn off the server and disconnect all cables. 3. Remove adap...

  • Page 23

    Chapter 2. Installing options 11 6. The following illustration shows how you route the scsi cable to the serveraid adapter. Attention: when you route the scsi cable, observe the following: • do not block the ventilated space in front of the fan assembly. • do not place the scsi cable fold on top of ...

  • Page 24

    12 ibm® netfinity® 6000r installation guide installing memory options before you install memory, review the following: • the dimm options available for your server are 128mb, 256mb, 512mb, and 1gb. Your server supports a maximum of 16 gb of system memory. • when 4 gb of memory is installed in the se...

  • Page 25

    Chapter 2. Installing options 13 note: the illustrations in this document might differ slightly from your hardware. Attention: when you handle electrostatic discharge-sensitive devices (esd), take precautions to avoid damage from static electricity. For details on handling these devices, refer to th...

  • Page 26

    14 ibm® netfinity® 6000r installation guide installing a drive in a hot-swap bay your server supports up to a maximum of six 1-inch (26 mm) slim-high, 3.5-inch, hot- swap hard disk drives in the hot-swap bays. The standard hot-swap bays are bays 1 through 3 (from bottom to top). The optional hot-swa...

  • Page 27

    Chapter 2. Installing options 15 installing a microprocessor your server comes standard with one microprocessor installed in microprocessor connector j34 (slot 1) on the system board, and a terminator card in microprocessor slot 4. The microprocessor in slot 1 is the startup (boot) microprocessor. I...

  • Page 28

    16 ibm® netfinity® 6000r installation guide note: the illustrations in this document might differ slightly from your hardware. Attention: when you handle electrostatic discharge-sensitive devices (esd), take precautions to avoid damage from static electricity. For details on handling these devices, ...

  • Page 29

    Chapter 2. Installing options 17 installing a hot-swap power supply if you install or remove a power supply, observe the following precautions: statement 8 caution: never remove the cover on a power supply or any part that has the following label attached. Hazardous voltage, current, and energy leve...

  • Page 30

    18 ibm® netfinity® 6000r installation guide note: the illustrations in this document might differ slightly from your hardware. To install an additional power supply: 1. Review the information in “safety” on page v. 2. Remove the filler panel. 3. Place the handle on the power supply in the open (down...

  • Page 31

    Chapter 2. Installing options 19 statement 6 caution: if you install a strain-relief bracket option over the end of the power cord that is connected to the device, you must connect the other end of the power cord to an easily accessible power source.

  • Page 32

    20 ibm® netfinity® 6000r installation guide cabling the server note: the illustrations in this document might differ slightly from your hardware. Refer to the following illustration for the location of the input and output connectors on your server. Refer to the following illustration for an example...

  • Page 33

    © copyright ibm corp. 2000 21 chapter 3. Starting the server use the following procedure to start your server. 1. Turn on all external devices, such as the monitor. Note: after you plug the power cords into outlets, wait 20 seconds before pressing the power control button. During this time, the syst...

  • Page 34

    22 ibm® netfinity® 6000r installation guide • if the server is turned on and a power failure occurs, the server will start automatically when power is restored. • the netfinity advanced system management processor also can turn on the server. You can turn off the server in several ways: • you can pr...

  • Page 35

    Chapter 3. Starting the server 23 information led panel the following illustration shows the server information panel. System power light: when this green light is on, system power is present in the server. When this light flashes, the server is in standby mode (the system power supply is turned off...

  • Page 36

    24 ibm® netfinity® 6000r installation guide.

  • Page 37

    © copyright ibm corp. 2000 25 chapter 4. Configuring your server the serverguide cds provide software setup tools and installation tools that are specifically designed for your ibm netfinity server. Use these cds during the initial installation of your server to configure basic hardware features and...

  • Page 38

    26 ibm® netfinity® 6000r installation guide after installing the nos be sure to take advantage of the following additional software that is included with the serverguide package: • operating system updates cds — include selected nos updates that are provided by nos software developers. • netfinity a...

  • Page 39

    © copyright ibm corp. 2000 27 chapter 5. Solving problems this section provides basic troubleshooting information to help you resolve some common problems that might occur while setting up your server. If you cannot locate and correct the problem using the information in this section, refer to the "...

  • Page 40

    28 ibm® netfinity® 6000r installation guide post error messages the following table provides an abbreviated list of the error messages that might appear during post. Note: see the "solving problems" section of the user’s reference on the ibm netfinity documentation cd for more information about the ...

  • Page 41

    Chapter 5. Solving problems 29 post message failing device or problem found suggested action 129 l1 cache of a microprocessor check the installation of your microprocessors. 162 change in device configuration verify that your optional devices are turned on and installed correctly. 163 time of day ha...

  • Page 42

    30 ibm® netfinity® 6000r installation guide serverguide startup problems look for the symptom in the left column of the chart. Probable solutions to the problem are in the right column. Setup suggested action netfinity setup and installation cd won’t start. • be sure the system is a supported netfin...

  • Page 43

    Chapter 5. Solving problems 31 troubleshooting chart notes: 1. Refer to the "solving problems" section of the user’s reference on the ibm netfinity documentation cd for more detailed troubleshooting charts. 2. If you cannot find the problem in the troubleshooting charts, run the diagnostic programs....

  • Page 44

    32 ibm® netfinity® 6000r installation guide power problems suggested action the server does not power on. Verify that: 1. The power cables are properly connected to the server. 2. The electrical outlet functions properly. 3. The type of memory that is installed is correct. 4. If you just installed a...

  • Page 45

    Chapter 5. Solving problems 33 option problems suggested action an ibm option that was just installed does not work. Verify that: 1. The server supports the option. Refer to the "support for netfinity servers" flowchart for information about obtaining serverproven™ compatibility information from the...

  • Page 46

    34 ibm® netfinity® 6000r installation guide.

  • Page 47

    © copyright ibm corp. 2000 35 appendix a. Product warranties and notices this chapter contains warranty and emission notices. It also contains trademarks and general-information notices. Warranty statements the warranty statements consist of two parts: part 1 and part 2. Part 1 varies by country. Pa...

  • Page 48

    36 ibm® netfinity® 6000r installation guide during the warranty period ibm or your reseller, if approved by ibm to provide warranty service, will provide repair and exchange service for the machine, without charge, under the type of service designated for the machine and will manage and install engi...

  • Page 49

    Appendix a. Product warranties and notices 37 upgrade. Many features, conversions, or upgrades involve the removal of parts and their return to ibm. A part that replaces a removed part will assume the warranty service status of the removed part. Before ibm or your reseller exchanges a machine or par...

  • Page 50

    38 ibm® netfinity® 6000r installation guide some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Ibm statement of warranty worldwide except canada, puerto rico, turkey, united states (part 1 – g...

  • Page 51

    Appendix a. Product warranties and notices 39 conditions of merchantability and fitness for a particular purpose. These warranties give you specific legal rights and you may also have other rights which vary from jurisdiction to jurisdiction. Some jurisdictions do not allow the exclusion or limitati...

  • Page 52

    40 ibm® netfinity® 6000r installation guide ibm is responsible for loss of, or damage to, your machine while it is 1) in ibm’s possession or 2) in transit in those cases where ibm is responsible for the transportation charges. Neither ibm nor your reseller is responsible for any of your confidential...

  • Page 53

    Appendix a. Product warranties and notices 41 limitation of liability: the following is added to this section: where ibm is in breach of a condition or warranty implied by the trade practices act 1974, ibm’s liability is limited to the repair or replacement of the goods or the supply of equivalent g...

  • Page 54

    42 ibm® netfinity® 6000r installation guide the laws of austria govern this statement if the warranty service is provided in albania, armenia, belarus, bosnia and herzegovina, bulgaria, croatia, czech republic, federal republic of yugoslavia, georgia, hungary, kazakhstan, kirghizia, former yugoslav ...

  • Page 55

    Appendix a. Product warranties and notices 43 greater of irish pounds 75,000 or 125 percent of the charges (if recurring, the 12 months’ charges apply) for the machine that is the subject of the claim or which otherwise gives rise to the claim. Applicability of suppliers and resellers (unchanged). T...

  • Page 56

    44 ibm® netfinity® 6000r installation guide notices references in this publication to ibm products, programs, or services do not imply that ibm intends to make these available in all countries in which ibm operates. Any reference to an ibm product, program, or service is not intended to state or imp...

  • Page 57

    Appendix a. Product warranties and notices 45 note to u.S. Government users — documentation related to restricted rights — use, duplication or disclosure is subject to restrictions set forth in gsa adp schedule contract with ibm corp. Year 2000 readiness and instructions this is a year 2000 readines...

  • Page 58

    46 ibm® netfinity® 6000r installation guide lotus and domino are trademarks of lotus development corporation in the united states, other countries, or both. Tivoli and netview are trademarks of tivoli systems inc. In the united states, other countries, or both. Intel, mmx, landesk, pentium, pentium ...

  • Page 59

    Appendix a. Product warranties and notices 47 properly shielded and grounded cables and connectors must be used in order to meet fcc emission limits. Ibm is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized change...

  • Page 60

    48 ibm® netfinity® 6000r installation guide taiwan electrical emission statement japanese voluntary control council for interference (vcci) statement power cords for your safety, ibm provides a power cord with a grounded attachment plug to use with this ibm product. To avoid electrical shock, always...

  • Page 61

    Appendix a. Product warranties and notices 49 ibm power cord part number used in these countries and regions 13f9940 argentina, australia, china (prc), new zealand, papua new guinea, paraguay, uruguay, western samoa 13f9979 afghanistan, algeria, andorra, angola, austria, belgium, benin, bulgaria, bu...

  • Page 62

    50 ibm® netfinity® 6000r installation guide.

  • Page 63: Index

    51 index a acoustical noise emissions 2 adapter installing 8 specifications 2 b beep codes 27 c cable routing 20 cabling the server 20 cd-rom 2 class a electronic emission notice 46 components, major 4 configuration/setup utility pro- gram 25 configuring your server 25 controls and indicators 21 d d...

  • Page 64

    52 ibm® netfinity® 6000r installation guide.

  • Page 66