ICharger 106B+ User Manual - page 8
-8-
iCharger Synchronous Balance Charger/Discharger 106B+
Keyboard basics
1. Go to the main menu, press the Incbutton or the Stop/Batt type buttonto go down, and press the
Dec button to go up: press the Start/Enter button to enter a sub-menu.
2. In a sub-menu, press Start/Enter to blink the chosen item, and then alter the value with Inc or Dec.
With nothing blinking you can go to the sub-menu below with Incand above with Dec. Press
Stop/Batt type to go back to the previous screen.
3. In some sub-menus, press and hold Start/Enter for more than 3 seconds to start the process, such as
starting charging or discharging.
4. During the charging/discharging process you can terminate the process at any time by pressing
Stop/Batt type and check the attached information with IncorDec. Press Start/Enter to go back to
the main information screen.
5. During the discharge process, press Start/Enter to alter the discharge current. When the discharge
current blinks, press Incto increase it or Dec to decrease it, then press Start/Enter to confirm the
change.
6. Press Stop/Batt type for more than 3 seconds to start the display of the active test information as per
the following diagram.
Present testing information:
7. Reset to Defaults function. Press
Stop/Batt type and Start/En
ter together for more than 3 seconds to
obtain this display:
Standard battery parameters
LiPo
LiIo
LiFe
NiCd
NiMH
Pb
Nominal voltage
3.7 V/cell
3.6 V/cell
3.3 V/cell
1.20 V/cell 1.20 V/cell
2.0 V/cell
Max. charge voltage
4.2 V/cell
4.1 V/cell
3.6 V/cell
1.60 V/cell 1.60 V/cell 2.45 V/cell
Storage voltage
3.85 V/cell
3.75 V/cell
3.3 V/cell
n/a
n/a
n/a
Allowable fast charge
current
≤ 1C
≤ 1C
≤ 4C
1C –
2C
1C –
2C
≤ 0.4C
Min. discharge voltage
cut-off level
cut off level
≥ 3.0 V/cell ≥ 2.5 V/cell ≥ 2.0 V/cell ≥ 0.85V/cell ≥ 1.0 V/cell ≥ 1.75V/cell
NOTE: Be very careful to choose the correct voltage for different types of battery otherwise you may cause
damage to the batteries. Incorrect settings could cause the cells to vent, burn or explode leading to injury or
loss of property.
In the parameter setting chapter that follows the screen diagram on the left shows the system‘s default
setting.
Resume defaults?
CONFIRM (ENTER)
Vi11.94V Int30℃
Vo 8.23V Ext25℃
Output
Volt.
Input
Volt.
Int.
Temp.
Ext.
Temp.
Inc
1:4.11 4.12 ----
4:---- ---- ----
1: 21 24 m
Ω
4: m
Ω
Dec
Battery Pack IR
45m
Ω
Dec
In this display the output voltage is the idle voltage measured at the
output terminals (that is, the voltage of the connected battery pack).
Individual cell voltage from
the balance port.
Per cell resistance from
the balance port.
Stop/Batt type
>3 seconds
Pressing Start for 3 seconds to monitor the resistance again.
Press Start/Enter to reset all values to the system-default settings.
Pack cells resistance from
the balance port.