Input:
• Voltage: Millivolt to 30 VAC/VDC
• DCPower: 3 volts (2 “AA” alkaline batteries included)
Output:
• Maximum: 1 amp per terminal (3 amp total for all terminals)
• Temperaturecontrolranges:45°F to 90°F (7°C to 32°C) Accuracy: ± 1°F (± 0.5°C)
• Differentialrange:1°F to 3°F (0.5°C to 1.5°C)
• Systemconfigurations: Single-stage heat, single-stage cool
or single-stage heat pump, gas, oil,
electric
• Terminations: RC, RH, W, Y, O, B, G
SET
ROOM
LO BAT
DIFF
Low battery signal
Temperature
differential setting
Room temperature
Room temperature
setpoint
• Always turn off the thermostat before installing, removing, cleaning, or servicing; turn off the power at
the main power source by unscrewing fuse or switching off circuit breaker
• Do not switch to “Cool” if room temperature is below 50°F (10°C); this could damage your A/C system
and cause injury
• Do not install on voltages higher that 30 VAC
• All wiring must conform to local and national building and electrical codes and ordinances
• While cleaning, do not get soap directly on thermostat switches or LCD readout; only use a damp cloth
with a mild soap to wipe outside of thermostat cover