Heat pump 7-day programmable hardwired sc 3201 programmable electronic thermostat installation, operation & application guide for more information on our complete range of american-made products – plus wiring diagrams, troubleshooting tips and more, visit us at www.Icmcontrols.Com •7-dayprogrammable...
Table of contents simplecomfort ® 3201partsdiagram.......................................................................................... 1 specifications.............................................................................................................................. 2 importantsafet...
Simplecomfort® 3201 parts diagram fan switch reset button cool emer off on auto heat y2 y1 e g w2 o b mode/hold switch system switch c l r mode hold.
Electricalrating: •24vac(18-30vac) •1ampmaximumperterminal •4ampmaximumtotalload •60minutepowerlossbackupforclock temperaturecontrolrange:45°fto90°f(7°cto32°c)accuracy:±1°f(±0.5°c) systemconfigurations:2-stageheat,2-stagecool,heatpump terminations:c,l,r,b,o,w2,g,e,y1,y2 specifications warning!:alway...
Electricalshockhazard–turnoffpoweratthemainservicepanelbyremovingthefuse orswitchingtheappropriatecircuitbreakertotheoffpositionbeforeremovingtheexisting thermostat. 1. Turnoffpowertotheheatingandcoolingsystembyremovingthefuseorswitchingtheappropriate circuitbreakeroff. 2. Removecoverofoldthermostat...
To install thermostat (continued) 2. Toremovecover,insertandtwistacoinorscrewdriverintheslotsonthesidesofthethermostat. 3. Putthermostatbaseagainstthewallwhereyouplantomountit(besurewireswillfeedthroughthe wireopeninginthebaseofthethermostat). 4. Marktheplacementofthemountingholes. 5. Setthermostatb...
Wiring diagrams simplecomfort ® 3201electronicthermostatconversionto: carrier split stream condensers and heat pump systems sc 3201 electronic thermostat.
Simplecomfort ® 3201electronicthermostatconversionto: coleman 3000 series heat pump systems sc 3201 electronic thermostat.
Simplecomfort ® 3201electronicthermostatconversionto: comfortmaker cyc series heat pump systems sc 3201 electronic thermostat (capped) (capped).
Simplecomfort ® 3201electronicthermostatconversionto: heil-quaker 867.814 series and ph50 series heat pump systems sc 3201 electronic thermostat (capped).
Simplecomfort ® 3201electronicthermostatconversionto: payne reliant and endura model heat pump systems sc 3201 electronic thermostat (capped).
0 simplecomfort ® 3201electronicthermostatconversionto: rheem/ruud: -pgb, -pfa, -pcb, -pla, and -pka series heat pump systems sc 3201 electronic thermostat.
Simplecomfort ® 3201electronicthermostatconversionto: goodman, janitrol, trane/american standard heat pumps sc 3201 electronic thermostat (capped) (capped).
Simplecomfort ® 3201electronicthermostatconversionto: york e1cs, e1fb, e1fh heat pump systems sc 3201 electronic thermostat.
Simplecomfort ® 3201electronicthermostatconversionto: lennox cb19 heat pump systems sc 3201 electronic thermostat.
Simplecomfort ® 3201electronicthermostatconversionto: lennox hp19 and hp20 heat pump systems sc 3201 electronic thermostat.
Simplecomfort ® 3201electronicthermostatconversionto: lennox hp21 with cb21 pcb heat pump systems sc 3201 electronic thermostat.
Simplecomfort ® 3201electronicthermostatconversionto: lennox hp22 with cb19 pcb heat pump systems sc 3201 electronic thermostat.
Thesimplecomfort ® 3201thermostathasbuttonsthatareusedto: •adjustthesetpointsofthethermostat •setthemodes •programtheschedule setting the room temperature (setpoint temperature) 1.Withthesystemswitchincool,heat,oremer,thecurrenttemperaturesetpointdisplays. 2.Pressthe or buttonuntilthedesiredtemperat...
Therearethreeledindicatorslocatedonthefrontofthethermostat.Theyaredesignedtoinformyou aboutthefollowing: led color function aux green •thisturnsonwhentheauxiliary(backup)heatingisinoperation •thisisthesecond(non-economy)stageofheat •itturnson2degreesbelowfirststageandisnotadjustable check red •whent...
Caution!: donotuseairconditioningwhentheoutdoortemperatureisbelow50degrees.This candamageyourairconditioningsystemandcausepersonalinjuries. 1. Movethefanauto/onswitchtotheautoposition.Onpositionrunsindoorfancontinuously. 2. Movethesystemswitchtocoolorheat,dependingontheseason. Starting the thermosta...
0 oncethethermostatisinstalled,itshouldbethoroughlytested. Caution!:donotenergizetheairconditioningsystemwhentheoutdoortemperatureisbelow 50degrees.Itcanresultinequipmentdamageorpersonalinjury. Note: beforetestingthesc3201,movethefanauto/onswitchtotheautoposition. Cooltest 1. Slidesystemswitchtocool...
Emergencyheattest 1. Slidesystemswitchtoemerposition.Emerheatmodescreenisdisplayed(emerledlights). 2. Adjustsettemperaturesoitis5degreesaboveroomtemperature. 3. Secondstageheatshouldcomeonwithinafewseconds(auxledlights). 4. Adjustthesettemperature2degreesbelowtheroomtemperatureandtheheatshouldturnof...
Offmode •inthismode,thethermostatwillnotturnontheheatingor coolingdevices(manualfancanoperate) •offmodeisalsousedtoaccesssetupandprogrammodes coolmode •inthismode,thethermostatcontrolsthecoolingsystem •pressthemodebuttontoenterandexitprogramcoolmode •inprogramcool(progdisplays)mode,thethermostatwill...
Thetimeanddayoftheweekmustbesetforyourprogramscheduletooperatecorrectly. 1. Slidethesystemswitchintotheoffposition. 4. Pressthe buttonwhilethetimeisdisplayed.Thedisplayshowstheday currentlysetonthethermostat(1=monday,2=tuesday,etc). 5. Pressthe or buttontosetthecorrectdayoftheweekthattodayis. Note:s...
Program overview thesc3201programmablethermostathasfourperiods(morn,day,eve,nite)thatarecustomizable foreachdayoftheweek.Eachperiodwillhaveasettime,heattemperature,andcooltemperature.The sc3201monitorsthedayandtime,whilemaintainingthespecificconditionsyouhavechosenforeach periodinyourprogram. 1.Plac...
Programming (continued) •settimeisdisplayed 8. Pressthe or buttontochangesettime. 9. Pressthe buttontoadvancetothenextscreen. Note:transitionsrequiredafter11:59pmmustbeprogrammedinthe nextday’smornperiod. •heattemperatureisdisplayed(50°fto90°f) 10. Pressthe or buttontoadjustheatsettemperature. 11. P...
Simpleset ® programmingisaconvenientmethodofprogrammingthethermostat.Oncetheentiremonday (day1)scheduleisset,simpleset ® programmingwillcopythemondayscheduletoeverydayoftheweek. Afterthecompletemondayscheduleisset(seeprogrammingonpage24),youareattheday2screen: 1. Pressthe buttononce.Day1screendispla...
Usethefollowingpersonalprogramscheduletorecordyoursettings: morn day eve nite heat heat heat heat cool cool cool cool monday 1 morn day eve nite heat heat heat heat cool cool cool cool tuesday 2 morn day eve nite heat heat heat heat cool cool cool cool wednesday 3 morn day eve nite heat heat heat he...
Personal program schedule (continued) morn day eve nite heat heat heat heat cool cool cool cool friday 5 morn day eve nite heat heat heat heat cool cool cool cool saturday 6 morn day eve nite heat heat heat heat cool cool cool cool sunday 7.
Symptom remedy nodisplay checkfor24vacatthermostat;displayisblankwhen24vacisnotpresent systemfandoesnotcomeonproperly verifywiringiscorrect allthermostatbuttonsareinoperative verify24vacispresent;unitlocksoutwhen24vacisnotpresent programscheduleactivatesatthe wrongtime checktime(am/pm)setonthermosta...
One-year limited warranty thesellerwarrantsitsproductsagainstdefectsinmaterialorworkmanshipforaperiodofone (1)yearfromthedateofmanufacture.Theliabilityofthesellerislimited,atitsoption,torepair, replaceorissueanon-casecreditforthepurchasepricesofthegoodswhichareprovidedto bedefective.Thewarrantyandre...