ICM Controls SC 5011 Installation, Operation & Application Manual - Mode of Operation

Manual is about: Programmable Electronic Thermostat

Summary of SC 5011

  • Page 1

    1 heat/1 cool auto changeover hardwire sc 5011 programmable electronic thermostat installation, operation & application guide for more information on our complete range of american-made products – plus wiring diagrams, troubleshooting tips and more, visit us at www.Icmcontrols.Com •7-day,5-2-dayor5-...

  • Page 2: Table of Contents

    Table of contents partsdiagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 icondescriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 specifications . ....

  • Page 3: Parts Diagram

    S1 s2 y w o/b g rc rh c reset config rc rh parts diagram configurationswitch resetswitch left(system) button right(fan) button downbutton upbutton fieldprogrammingpins rc/rhjumper fp.

  • Page 4: Specifications

    Specifications icon descriptions fanoperationicon coolingoperationicon heatingoperationicon lockmode activated room temperature offsetactivated electricalrating: •24vac(18-30vac) •1ampmaximumperterminal •3ampmaximumtotalload temperaturecontrolrange:45°fto90°f(7°cto32°c)accuracy:±1°f(±0 .5°c) systemc...

  • Page 5: Important Safety Information

    Package contents/tools required packageincludes:simplecomfort ® pro5011thermostatonbase,thermostatcover,wiringlabels, screwsandwallanchors,installation,operationandapplicationguide toolsrequiredforinstallation:drillwith3/16”bit,hammer,screwdriver important safety information warning!: alwaysturnoffp...

  • Page 6: To Install Thermostat

    To install thermostat electricalshockhazard –turnoffpoweratthemainservicepanelbyremovingthefuse orswitchingtheappropriatecircuitbreakertotheoffpositionbeforeremovingtheexisting thermostat. Important: thermostatinstallationmustconformtolocalandnationalbuildingandelectrical codesandordinances . Note: ...

  • Page 7: Wiring Diagrams

    Hardwired 3-wire, single transformer hardwired 4-wire, single transformer wiring diagrams.

  • Page 8

    Hardwired 5-wire, two transformer (both transformers must be in phase) hardwired 4 or 5-wire, single transformer fan control important: before wiring, remove pre-installed rc/rh jumper..

  • Page 9

    Hardwired cool or heat active reversing valve.

  • Page 10

    Hardwired 4-wire, single transformer.

  • Page 11

    Remote or outdoor sensor installation (optional) 1 . Removecoverfromremotesensorhousing . 2 . Selectanappropriatelocationformountingtheremotesensor . 3 . Mountremotesensorunitusinghardwareprovided . 4 . Installtwostrandshieldedwirebetweenremotesensorandthermostat .Shieldedwiremustbeused .Donot runre...

  • Page 12: Configuration Mode

    0 configuration mode off pm 1 . Verifythesc5011isintheoffmode . Pressthesys(left)buttonuntiloffmodedisplays . 2 . Removethecoverofthethermostatbygentlypullingnearoneofthe cornersatthetopofthethermostat . 3 . Presstheconfigbuttonfor1secondwhilethesc5011isinoffmode . Toexitconfigurationmode,presstheco...

  • Page 13: Configuration Mode Settings

    Configuration mode settings thesetupscreensforconfigurationmodeareasfollows: 3 .Deadband(1°f-9°f)(1°c-5°c) settheminimumnumberofdegreesbetweenyourheatsetpointandyour coolsetpointinautochangeovermode . Presstheupordownbuttontosetdeadbandvalue . Presstherightbuttontoadvancetothenextscreen . 2 .Tempera...

  • Page 14

    Presstheupordownbuttontoselect . Presstherightbuttontoadvancetothenextscreen . 4 . System–setforheatpump,non-heatpump,reversingvalveoperationandnumberofcompressors inyoursystem . Choose system reversing valve active number of compressors or compressor stages type of heat heat pump hp o 1 hp b 1 non-...

  • Page 15

    5 . Lockout(0-8°,nite,cool-heat) selectthenumberofdegreessettemperaturecanbechangedduring keypadlockoutorselecttolockoutduringniteperiodonly .Cool-heat lockoutallowsadjustmentofthesettemperaturestothemaximumheatset temperatureselectedinstep6andminimumcoolsettemperatureselectedin step7 . Note:themode...

  • Page 16

    10 . Temperaturesensor(1-4) 1 .Onlyon-boardsensordeterminesroomtemperature . 2 .Onlyremotesensordeterminesroomtemperature . 3 .Averagetemperatureofon-boardandremotesensor . 4 .Onlyon-boardsensorwillbeuseduntilniteperiod,andthenonlyremote sensorisused . Presstheupordownbuttontoselect . Presstherightb...

  • Page 17

    12 . Statusindicatorlight(led0or1) 0=statusindicatorneveron 1=statusindicatoronwithfirststage presstheupordownbuttontoselect . Presstheconfigbuttonfor2secondstoexitconfiguration . Off 11 . Coolingfandelayofftime(0,30,60,90seconds) selectthefanpurgetimeforcooling . Presstheupordownbuttontoselect . Pr...

  • Page 18: Mode of Operation

    Mode of operation thesc5011isaprogrammable,manualorautochangeover,single-stageheat,single-stagecool thermostat .Itfunctionswithairconditioning,heatpumps,gas,oilorelectricheatsystems . Thethermostatactivatestheheatingappliancewhentheroomtemperatureisbelowthesetheat temperature(bythedifferentialtemper...

  • Page 19: Operating Modes

    Operating modes therearefivepossibleoperatingmodesforthesc5011 .Off,cool,heat,andcool&heatmodesare accessedbypressingthesys(left)button .Programmodeisaccessedbypressingthesys(left)and fan(right)buttonssimultaneously . Off mode •inthismode,thethermostatwillnotturnontheheatingorcooling devices note: t...

  • Page 20

    Prog prog prog cool and heat mode (auto changeover) •inthismode,thethermostatcontrolsthecoolingandheatingsystems, automaticallychangingoverfromonetotheotherasneeded . •thetimingdisplayalternateswiththesettemperatureevery10 secondsinthecoolandheatmode . Program mode •inthismode,theprogramfunctionison...

  • Page 21: Testing The Thermostat

    Testing the thermostat oncethethermostatisconfigured,itshouldbethoroughlytested . Caution!: donotenergizetheairconditioningsystemwhentheoutdoortemperatureis below50degrees .Itcanresultinequipmentdamageorpersonalinjury . Fan test 1 . Pressfan(right)button .Fandisplays .Indoorfanturnson . 2 . Pressfan...

  • Page 22

    0 setting the time and day of the week today mon 5 . Pressthefan(right)buttononcetoselectdayoftheweek(today flashing) . Presstheupordownbuttontoselectcurrentdayoftheweek . Note:atanytime,pressthesys(left)buttontoreturntotheprevious screenorpressthefan(right)buttontoadvancetothenextscreen . Pressthep...

  • Page 23: Programming

    Programming settingtheprogramschedule: 1 . Pressthesys(left)buttonuntilyouareinoffmode . 2 . Pressandholdtheprogbutton(sysandfanbuttonspressedsimultaneously)for6seconds . 3 . Pressthefan(right)button3times . 4 . Sunthrusatareblinking . Sun mon tue wed thu fri sat prog fromthisscreenyouhave2options: ...

  • Page 24

    Fromanyofthescreensonpage21,youcanpressthefan(right)buttontobeginenteringyour programschedule .Thedaysshownonthedisplaywillallbeprogrammedsimultaneously . Oncethefan(right)buttonispressed,mornblinks . Usetheupordownbuttontoselectadifferentperiod(morn,day,eve,nite) . Pressfan(right)buttontoadvancetot...

  • Page 25: Lockout Feature

    Lockout feature thesc5011hasabuttonlockoutfeaturesothemodecannotbechanged andthetemperatureadjustmentislimited .Selecttheappropriatelockout fromconfigurationmodesettings(step5,page13)ofthisguide . Toactivatethelockfeature: 1 . Simultaneouslypressthesys,fanandupbuttonsfor10seconds . 2 . Willdisplayan...

  • Page 26: Factory Preprogramming

    Factory preprogramming usethefollowingpersonalprogramscheduletorecordyoursettings: thesc5011comespreprogrammedwiththefollowingschedule: morn 6:00 am day 8:00 am eve 6:00 pm nite 10:00 pm heat 70°f heat 62°f heat 70°f heat 62°f cool 78°f cool 85°f cool 78°f cool 82°f fan off fan off fan off fan off m...

  • Page 27: Factory Preprogramming

    Factory preprogramming usethefollowingpersonalprogramscheduletorecordyoursettings: thesc5011comespreprogrammedwiththefollowingschedule: morn 6:00 am day 8:00 am eve 6:00 pm nite 10:00 pm heat 70°f heat 62°f heat 70°f heat 62°f cool 78°f cool 85°f cool 78°f cool 82°f fan off fan off fan off fan off m...

  • Page 28: Simpleset

    Simpleset tm field programming thisfeatureisusedfortransferringconfigurationandprogramschedulefromthemastertothetarget thermostat .Allthermostatsforajobcanbemountedandpoweredup .Configureandprogramone thermostat .Thiswillbethemaster .Themasterwillbeusedtocopytheprogramtotherestofthe thermostats . Pr...

  • Page 29: Troubleshooting

    Troubleshooting symptom remedy nodisplay checkfor24vacatthermostat;displayisblankwhen24vacisnotpresent timeanddayofweekmustberesetafterextendedpowerloss systemfandoesnotcomeonproperly verifywiringiscorrect,checkgas/electricconfiguration(seesetting4,page12) allthermostatbuttonsareinoperative verify24...

  • Page 30

    Thispageleftblankintentionally ..

  • Page 31

    Thispageleftblankintentionally ..

  • Page 32: One-Year Limited Warranty

    One-year limited warranty thesellerwarrantsitsproductsagainstdefectsinmaterialorworkmanshipforaperiodofone(1) yearfromthedateofmanufacture .Theliabilityofthesellerislimited,atitsoption,torepair,replace orissueanon-casecreditforthepurchasepricesofthegoodswhichareprovidedtobedefective .The warrantyand...