Icom IC-PW1 Instruction Manual

Summary of IC-PW1

  • Page 1

    Instruction manual ipw1 hf/50 mhz all band 1 kw linear amplifier.

  • Page 2

    R warning high voltage! Never attach an antenna or internal antenna connector during trans- mission. This may result in an electrical shock or burn. R warning! Never carry the linear amplifier by yourself. At least two persons must carry the linear amplifier since it weights approx. 25 kg (55 lb). R...

  • Page 3

    Important ...................................................... I precautions ................................................. I explicit definitions .................................. Ii table of contents .................................... Ii unpacking .............................................

  • Page 4

    1 1 panel description ■ front panel and remote controller 0 100 250 500 1k 1.5k 0 temp alc alc adj swr 0 1 1.5 2 3 10 20 30 40 50 60 v d hot i d po 10 20 30 40 50 60 w a meter-1 meter-2 p o temp i d v d alc swr down 1.8 3.5 7 10 14 18 21 24 28 50 up ant input auto transmit tuner amp/ protect power v...

  • Page 5

    2 1 panel description q power switch [power] (p. 11) push momentarily to turn power on. W transmit indicator [transmit] (p. 13) lights green while transmitting. During transmission, a humming may sound de- pending on the output power. This is caused by the large current produced by the power supply ...

  • Page 6

    Q output antenna connectors [ant1] – [ant4] (p. 6) accept a 50 Ω antenna with a pl-259 connector. W accessory socket-1 [acc-1] accessory socket-2 [acc-2] enable connection to icom exciters (transceivers). - see the page at right for socket information. - the [acc-2] socket is connected in parallel w...

  • Page 7

    4 1 panel description d acc-1 socket d acc-2 socket (w/[exciter] is “1”) the following descriptions are applied when the [exciter] switch is set to “1” (default). When [ex- citer] is set to “1&2,” [acc-2] functions the same as [acc-1] above for the 2nd exciter. Acc-1 pin no. Pin name description spe...

  • Page 8

    5 2 installation and connections (1) single-phase 3-wire line (200–240 v ac) q the green wire from the ac power cable must be connected to the protective earth. W the black and white wires from the ac power cable can be connected to either terminal. *use the appropriate ac plug if required. (2) sing...

  • Page 9

    ■ grounding to prevent electrical shock, television interference (tvi), broadcast interference (bci) and other prob- lems, ground the linear amplifier through the ground terminal on the rear panel. For best results, connect a heavy gauge wire or strap to a long earth-sunk copper rod. Make the distan...

  • Page 10

    ■ system interconnections 1 or 2 icom 100 w hf transceivers can be connected as exciters to the ic-pw1. Non-icom transceivers can be used, however, band selection will not be synchro- nized for each exciter. See the following diagrams for making connections be- tween the ic-pw1 and an exciter (trans...

  • Page 11

    8 2 installation and connections • using 2 icom exciters (transceivers) the following connections also apply to trans- ceivers having multiple antenna connectors for specified bands (e.G. Ic-726, ic-729, etc.) ic-pw1 ic-756 ground coaxial cable (supplied) opk-5 (optional) acc cable (supplied) remote...

  • Page 12

    9 2 installation and connections • using 1 icom and 1 non-icom exciters (transceivers) note: the specifications for the send relay are 5 v dc 0.1 a. If this level is exceeded, a large ex- ternal relay must be used. • using non-icom exciters (transceivers) when the ic-pw1’s power is off to use the an...

  • Page 13

    10 2 installation and connections the control section of the linear amplifier can be sep- arated from the main body, doubling as a remote con- troller. It can be placed on the exciter or in another convenient place. Q disconnect the ac power cable. W remove 8 screws from the sides of the linear am- ...

  • Page 14

    ■ setting the alc levels before first applying power, make sure all connections required for your system are complete by referring to chapter 2. Then, reset the linear amplifier using the following procedure. Note: resetting clears all programmed set- tings to default values. Q make sure the linear ...

  • Page 15

    12 3 operation the ic-pw1 uses ci-v frequency data for automatic selection of the operating band. Program the exciter’s address to use this capability as follows: for non-icom exciters, the ic-pw1 cannot be con- trolled using the ci-v function, so this setting is not necessary. For transceivers whic...

  • Page 16

    13 3 operation caution: do not operate the ic-pw1 before adjusting the alc levels properly with the [alc adj1] and [alc adj2] pots. (p. 11) it takes 15 sec. For ci-v line initial settings when several ci-v devices (more than 5) are connected to a ci-v line. For ic-781 users with other icom ci-v tran...

  • Page 17

    3 operation 14 this linear amplifier has various protection circuits. D alc circuit the alc (automatic level control) circuit automati- cally limits rf output power by controlling the input level of the exciter. This prevents transmission of dis- torted signals when the input signal level exceeds th...

  • Page 18

    4 maintenance 15 problem possible cause solution ref. Power does not come on when the [power] switch is pushed. • cable connection is faulty. • the circuit breaker is turned off. • check the connection and connection cable pins. • check for the cause, then turn the circuit breaker on. Pgs. 7 – 9 p. ...

  • Page 19

    5 specifications 16 ■ general • frequency coverage: 0 1.800– 0 1.999 mhz 0 3.500– 1 3.999 mhz 0 7.000– 1 7.300 mhz 10.100–10.150 mhz 14.000–14.350 mhz 18.068–18.168 mhz 21.000–21.450 mhz 24.890–24.990 mhz * 1 28.000–29.700 mhz * 1 50.000–54.000 mhz * 1 the u.S.A. Version can only be used the antenna...

  • Page 20

    6-9-16 kamihigashi, hirano-ku, osaka 547-0002 japan a-5449g-1ex- w printed in japan © 1997 icom inc. Count on us!.