Icom PS-250 Instructions - Connections
• Mount the power supply securely with the four supplied
screws (M5
×
20 mm) to a surface which is more than 10
mm thick and can support more than 5 kg.
CAUTION:
KEEP the power supply at least 1 meter
away from your vessel’s magnetic navigation compass.
1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan
A-6654H-1EX
Printed in Japan
© 2008 Icom Inc.
12 V/24 V battery
or PS-240
PS-250
IC-GM651
KEEP
the terminal guard
attached after connecting
cables.
Supplied with
IC-GM651
Supplied with
PS-250
Fuse rating: 15 A
GND
Terminal guard
Detach the terminal guard first.
DC IN
12V/24V
DC OUT
12.5V
CONNECTIONS
Flat washer
Spring washer
Self-tapping
screw
INSTALLATION
• DC input voltage
: 10.8 V to 31.2 V DC
• Output voltage
: 12.5 V DC
• Maximum output current : 5.3 A (nominal)
• Usable temperature range : –15°C to +55°C
• Dimensions
: 250(W)
×
67(H)
×
200(D) mm
(projections not included)
• Weight (approx.)
: 2.1 kg
SPECIFICATIONS
Icom, Icom Inc. and the
logo are registered trademarks of Icom Incor-
porated (Japan) in the United States, the United Kingdom, Germany,
France, Spain, Russia and/or other countries.
All other products or brands are registered trademarks or trademarks of their
respective holders.
One fuse is installed in the supplied DC power cable. If a
fuse blows or the power supply stops functioning, track
down the source of the problem, if possible, and replace
the damaged fuse with a new, rated one.