M
M
Common 2 screen
D
D
SCRAMBLER TYPE (UT-110 only)
Set the UT-110 Rolling type scrambler as UT-109 Non-
rolling type. As UT-110 and UT-109 have different code
settings, they are not compatible.
By selecting Non-rolling type in this item, you can use
UT-110 as UT-109.
➥
Selectable value;
Rolling type (UT-110 normal)
Non-rolling type (UT-110 functions as UT-109)
NOTE: This setting is invalid for UT-109.
D
D
SCRAMBLER GROUP CODE (UT-110 only)
UT-110 has 1020 (4 groups x 255) code numbers for
providing higher communication security. Use the same
scrambler group code for same group.
➥
Selectable value; 1 to 4.
NOTE: This setting is invalid for UT-109.
D
D
SYNCHRONOUS CAPTURE (UT-110 only)
"Synchronous capture mode" is useful when commu-
nicating through a repeater. However, because of voice
components, the transceiver can not maintain synchro-
nous mode in rare cases.
Normally it is best to set this item to "Standard".
➥
Selectable value;
Standard (Normal operation)
Continuous (repeater operation)
D
D
TONE START TIMING (UT-110 only)
Tone start timing selects the synchronous tone signal
transmit delay time.
Set the delay time when the other party's transceiver
has power save mode.
➥
Selectable value;
OFF(default)
0.300s, 0.600s, 1.100s
IC-F3GT/GS, IC-F4GT/GS SERIES CLONING -1
M
Edit Memory CH screen
D
D
SCRAMBLER ON/OFF/Inhibit
Turns the scrambler function "ON" or "OFF" as a initial
setting. This item can also be turned "ON" or "OFF"
with a program function switch when the function is as-
signed to a switch.
"Inhibit": This means the scrambler function selection
is inhibited.
D
D
Scrambler code
Set the scrambler code number.
Selectable value;
UT-109: 1 to 32
UT-110: 1 to 255
*UT-110 requires to set the scrambler group code (1
to 4) in the Common 2 screen. Use the same Group
Code and Scrambler code for same group.