Interlogix Alliance AL-4017 Installation Manual

Summary of Alliance AL-4017

  • Page 1

    Alliance al-4017/al-4617 control panel installation manual.

  • Page 2

    Copyright © 2012 utc fire & security americas corporation, inc. Interlogix is part of utc climate controls & security, a unit of united technologies corporation. All rights reserved. This document may not be copied or otherwise reproduced, in whole or in part, except as specifically permitted under ...

  • Page 3

    Iii 2. Term. This agreement is effective until terminated. You may terminate this agreement by uninstalling all components of the software from all computing devices and returning the licensed product to utc fire & security. Utc fire & security may terminate this agreement if you breach any of these...

  • Page 4

    Alliance al-4017/al-4617 control panel installation manual iv restricted rights legend. The licensed product is provided with restricted rights. In the event the united states government or an agency thereof is granted a license, the following additional terms apply: restricted computer software, as...

  • Page 5

    V fcc compliance part 15 notification this device complies with part 15 of the fcc rules. Operation is subject to the following conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operati...

  • Page 6

    Alliance al-4017/al-4617 control panel installation manual vi.

  • Page 7: Contents

    Vii contents preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ix conventions used in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Page 8

    Alliance al-4017/al-4617 control panel installation manual viii.

  • Page 9: Preface

    Ix preface this is the alliance al-4017/al-4617 control panel installation manual for models al-4017 and al-4617. This document includes an overview of the product and detailed instructions explaining: • how to install; and • how to wire the units. There is also information describing how to contact...

  • Page 10

    Alliance al-4017/al-4617 control panel installation manual x.

  • Page 11: Product Overview

    1 product overview alliance is a scalable access control platform integrated with a intrusion alarm package. The alliance control panels use a modular rs-485 data bus to provide continuous polling of remote arming stations (ras) and data control panels (dgp). These devices extend the system’s securi...

  • Page 12: Installation

    Alliance al-4017/al-4617 control panel installation manual 2 installation to install the control panel, do the following: 1. Mount the enclosure. A suitable location should include easy access for wiring, good lighting, suitable access to power and earth ground, and ample space to work. The mounting...

  • Page 13

    3 2. Install the standoffs. Before the board can be installed, you must configure the appropriate standoffs. Use male/female standoffs where threaded holes are aligned with the mounting holes on the board and use clip-in standoffs where square holes are aligned with the mounting holes (figure 2) fig...

  • Page 14

    Alliance al-4017/al-4617 control panel installation manual 4 6. Slide the board’s terminal blocks together as shown in figure 3 and mount them to the board. Figure 3. Terminal block assembly 7. Use four 6/32 x 1/4 in. Screws with internal star washers to mount the board (figure 4) in the enclosure (...

  • Page 15

    5 leds figure 4 on page 4 shows the following leds located on the board: l1. Flashes slowly when the panel is operating (the microprocessor is running). Rx (comms). Yellow led flashes when remote units (ras and dgp devices) are replying to polling. Tx (comms). Red led flashes when the panel is polli...

  • Page 16: Wiring

    Alliance al-4017/al-4617 control panel installation manual 6 wiring keep all panel wiring well away from other wiring. Avoid parallel wire runs with other wires. Where parallel wire are unavoidable, keep wires a minimum of 2 in. (5 cm) apart or in emt. We recommend that you wire alliance system comp...

  • Page 17

    7 system bus connections connect dgp devices to the system bus to provide extra zones and remote arming stations (ras) to the control panel. Remote devices can be up to 5,000 ft. (1.5 km) from an alliance system control panel. Dgp and ras devices must be connected via a twisted-pair, shielded data c...

  • Page 18

    Alliance al-4017/al-4617 control panel installation manual 8 auxiliary power supply connections in systems where expansion module power is not supplied by the main control panel or an ac-powered dgp with auxiliary outputs, you must use a ul listed power supply suitable for burglar alarm applications...

  • Page 19

    9 nonpower/power-limited wiring keep nonpower-limited wiring away (1/4 in. Minimum) from power-limited wiring (figure 8). Disconnect the ac power via a dedicated circuit breaker before servicing. Figure 8. Power and nonpower wiring nonpower- limited wiring power- limited wiring nonpower- limited wir...

  • Page 20

    Alliance al-4017/al-4617 control panel installation manual 10 control panel connections figure 9 shows the wiring connections on the control panel board. See battery capacity on page 14 for the appropriate battery type. To wire the panel, use these guidelines: • the total auxiliary power output is 3...

  • Page 21

    11 zone input connections figure 10 shows zone inputs connections. Figure 10. Alarm input and bell output wiring figure 11 shows single and dual zone alarm input wiring. Note: dual zone is not acceptable for ul 365, ul 609, and ul 1610 compliance. Figure 11. Single and dual zone alarm input wiring 1...

  • Page 22

    Alliance al-4017/al-4617 control panel installation manual 12 pstn connections figure 12 shows two methods to wire the control panel to a pstn connection. This equipment complies with fcc part 68 rules (us:geial07b3-4000).We recommend you wire the system to a dedicated pstn line. Figure 12. Pstn con...

  • Page 23: Installer Programming Menu

    13 installer programming menu refer to the alliance system programming manual for a complete programming map and programming instructions. The installer programming menu includes: 1. Zone database 28. To remote devices 2. Area database 29. Computer connection 3. Ras database 30. Printer 4. Dgp datab...

  • Page 24: Battery Capacity

    Alliance al-4017/al-4617 control panel installation manual 14 battery capacity you must do the battery capacity calculations separately for each part of the system that has a separate power supply and standby battery. See battery calculation worksheet on page 16 for a sample worksheet. To determine ...

  • Page 25

    15 4. Do the following calculations for each worksheet: formula 1. Transfer the total value at the bottom of the total standby current column to the first blank in formula 1. Enter the required number of hours in standby in the corresponding blank, and do the indicated calculation. The result is the...

  • Page 26

    Alliance al-4017/al-4617 control panel installation manual 16 battery calculation worksheet table 3. Battery calculation worksheet alliance components standby current total standby current alarm current per device total alarm current active current total active current al-4017 200 ma aux power 300 m...

  • Page 27

    17 formulas table 4 provides the formulas to calculate battery requirements. Table 4. Battery calculation formulas formula calculation result 1 total standby current x conversion factor x required hours in standby ma x .001amp/ma x hours ah standby amp-hours 2 total alarm current x conversion factor...

  • Page 28

    Alliance al-4017/al-4617 control panel installation manual 18 absolute maximum loads table 5 and table show the maximum continuous loads that can be supported by two 17.2 ah batteries or one 17.2 ah battery. If the total standby current exceeds those listed in the table, you do not meet 24/72-hour s...

  • Page 29: Specifications

    19 specifications general specifications these specifications are for the al-4017 and al-4617 main board (no accessories). Al-4017 external terminals 1. Al-1692 2. Al-1690, al-1691. Current consumption pcb 205 ma nominal end-of-line resistors default: 4.7 k ohm (other: 10 kohm, 6.8 kohm, 5.6 kohm, 3...

  • Page 30

    Alliance al-4017/al-4617 control panel installation manual 20 al-4617 external terminals 1. Combined loads not to exceed 3 a. Part terminal description min. Typ max unit j17 ac input 18 vac batt battery connection battery charge battery ah rating 9 17.2 12 14 1 34.4 vdc a ah j14 aux, power auxiliary...

  • Page 31: Ul Compliance Statement

    21 ul compliance statement to maintain compliance with ul365, ul609, and ul1610: mercantile premises alarm systems 1. Zone types 22, 28, 29, and 30 (auto reset) can not be used. 2. Force arming is not allowed (refer to the alliance system programming manual). 3. Siren time should be programmed for n...

  • Page 32: Contacting Technical Support

    Alliance al-4017/al-4617 control panel installation manual 22 contacting technical support for assistance installing, operating, maintaining, and troubleshooting this product, refer to this document and any other documentation provided. If you still have questions, you may contact technical support ...