Interlogix Concord 4 RF Installation Manual

Summary of Concord 4 RF

  • Page 1

    P/n 466-2371 • rev d • iss 19jul16 1 concord 4 installation guide content contact information 1 description 1 panel location 2 power and wire length 2 mounting the panel 3 programming 4 sensor group characteristics 7 specifications 9 regulatory information 9 contact information for contact informati...

  • Page 2: Panel Location

    2 concord 4 installation guide phone line connection allow s panel to communicate w ith central monitoring station and/or pagers. Note: the total current sourced from all terminals cannot exceed 1 amp. Panel location before permanently mounting the panel, use the following guidelines to choose a mou...

  • Page 3: Mounting The Panel

    Concord 4 installation guide 3 device max. W ire length to panel standby m a draw alarm m a draw interrogator avm 22 ga.: 110 ft. 18 ga.: 260 ft. 45 ma 300 ma tw o-w ire smoke detectors (429at, 429c, 429ct, 521b, 521bxt, 521ncsxt 22 ga.: 330 ft. 18 ga.: 330 ft. 70 ua 60 ma tw o-w ire smoke detectors...

  • Page 4: Programming

    4 concord 4 installation guide grounding the panel for maximum protection from lightning strikes and transients, connect the enclosure to earth ground. Use 16-gauge, solid copper wire from an earth grounded cold water pipe clamp to the enclosure. For best results , we recommend that you crimp a spad...

  • Page 5

    Concord 4 installation guide 5 only when the display shows system programming can you advance to tier 2 programming menus. Press b or # to advance forward through menus. Press a or * to move backward through the menus. Only when a specific menu is displayed can you advance to those menu settings. Fo...

  • Page 6

    6 concord 4 installation guide are adding (learning) into the panel memory to send a signal to the panel. 7. To add another sensor to the same sensor group and partition, repeat the process. 8. To add sensors to another sensor group or partition, press * twice and repeat the process. Table 8 below d...

  • Page 7

    Concord 4 installation guide 7 sensor group characteristics table 10 below shows what the sensors on your concord 4 system do. Every sensor is assigned to a group, and this table specifies those groups and functions. Every device must be assigned to one of these groups. Note: the “x” marks in the ta...

  • Page 8

    8 concord 4 installation guide num ber nam e application alarm delay restoral supervisor y cs report chim e (level) active (level) 19 delayed interior interior doors that initiate a delay before going into alarm 1 police interior x x x 3 20 delayed interior pir motion sensors that initiate a delay b...

  • Page 9: Specifications

    Concord 4 installation guide 9 specifications pow er requirements class 2, 16.5 vac, 40 va, 60 hz (600-1023 or 600-1024) rechargeable battery: 12 vdc, 4.5 or 5.0 ah lead-acid (60-681) or 12 vdc, 7 ah (60-680). The battery w ill last 24 hours w ith no ac and specified stand-by load. Auxiliary pow er ...

  • Page 10

    10 concord 4 installation guide table 11: sia setting requirements function default setting required setting exit extension on on duress code disabled disabled dialer abort delay 30 seconds 15 to 45 seconds cancel message on on call w ait cancel disabled on if reporting to central station and custom...

  • Page 11

    Concord 4 installation guide 11 note: the installer must verify the compatibility between this panel and the central station receivers being used. Ul canada listed installations this section describes the requirements for cul (ul canada) listed installations. Residential burglary alarm system unit (...