Interlogix NX-148E-RF Installation Instructions Manual

Summary of NX-148E-RF

  • Page 1

    P/n 466-2198 • rev f • oct12 nx-148e-rf lcd touchpad with receiver installation instructions content contact information 1 product summary 1 installation 2 transmitter programming 2 touchpad programming 5 reference tables 9 specifications 14 regulatory information 14 contact information www.Utcfirea...

  • Page 2

    2 nx-148e-rf lcd touchpad w ith receiver installation instructions installation to install the touchpad, do the following: 1. Remove the mounting-plate screw ( figure 1 ) from the bottom of the touchpad and lift off the mounting plate. Caution: you must be free of static electricity before handling ...

  • Page 3

    Nx-148e- rf lcd touchpad w ith receiver installation instructions 3 rm: receiver module he: hardwire expander p: panel this gives you all the programming information in one place and facilitates the programming process. Zone locations 401 to 592 zone locations 401 to 592 are not numbered in table 11...

  • Page 4

    4 nx-148e-rf lcd touchpad w ith receiver installation instructions 9. To program remaining transmitters, repeat steps 6 to 8. 10. To exit program mode, press exit exit. Transmitter options door/window transmitter settings to set features 4 (input option 1) and 5 (input option 2) for door/window tran...

  • Page 5

    Nx-148e- rf lcd touchpad w ith receiver installation instructions 5 4. Enter the zone location and press #. For example, enter 407 # to delete zone 7. 5. To change transmitter feature 1 (transmitter enabled), enter 1 and press *. The 1 turns off to indicate the feature change. 6. To delete additiona...

  • Page 6

    6 nx-148e-rf lcd touchpad w ith receiver installation instructions service menu (2) a service required message will display periodically if the system requires service. To access the service menu, do the following: 1. Enter * 2 to display one or more of the fault messages in table 9 . 2. Press or to...

  • Page 7

    Nx-148e- rf lcd touchpad w ith receiver installation instructions 7 assign user authority (6) to assign user authority levels, you must have authority over the assigned partitions. To assign user authority, do the following: 1. Enter * 6. 2. Enter your master code. 3. Enter the user number. 4. Use k...

  • Page 8

    8 nx-148e-rf lcd touchpad w ith receiver installation instructions table 7. Editing character data com mand action * saves character or w ord. Moves cursor to the right. Cancel moves cursor to the left. Scrolls through available characters. In library mode, scrolls through available w ords. Stay ins...

  • Page 9

    Nx-148e- rf lcd touchpad w ith receiver installation instructions 9 silent exit (exit) to silence the exit beeps during exit delay (while the system is disarmed), do the following: 1. Enter * exit. 2. Enter your user code. 3. To exit, press #. Reference tables table 9. Service menu messages message ...

  • Page 10

    10 nx-148e-rf lcd touchpad w ith receiver installation instructions man test manual test - bell and/or communicator test w hile system is disarmed. Re-exit the exit delay has been restarted w ithout disarming the system. Output trip a trip has occurred on an expander auxiliary output. Data lost comm...

  • Page 11

    Nx-148e- rf lcd touchpad w ith receiver installation instructions 11 zone _____ assigned to module #_____. Rm he p 1 - enable sensor 2 - supervised 3 - fire supervision 4 - input option 1 5 - input option 2 _ 6 - 8 not used partition 1 keyfob partition 2 keyfob partition 3 keyfob partition 4 keyfob ...

  • Page 12

    12 nx-148e-rf lcd touchpad w ith receiver installation instructions zone _____ assigned to module #_____. Rm he p 1 - enable sensor 2 - supervised 3 - fire supervision 4 - input option 1 5 - input option 2 _ 6 - 8 not used partition 1 keyfob partition 2 keyfob partition 3 keyfob partition 4 keyfob p...

  • Page 13

    Nx-148e- rf lcd touchpad w ith receiver installation instructions 13 zone _____ assigned to module #_____. Rm he p 1 - enable sensor 2 - supervised 3 - fire supervision 4 - input option 1 5 - input option 2 _ 6 - 8 not used partition 1 keyfob partition 2 keyfob partition 3 keyfob partition 4 keyfob ...

  • Page 14

    14 nx-148e-rf lcd touchpad w ith receiver installation instructions specifications compatibility compatible w ith all netw orx control panels except cf (commercial fire) panels frequency 319.5 mhz wireless range 600 feet (183 m) open air required pow er 12.0 vdc (provided by panel) current draw 75 m...