Intermatic ET70115C User Manual

Manual is about: Intermatic ET70115C Time Switches: User Guide

Summary of ET70115C

  • Page 1

    • introduction 2 • led display 3 • reset 3 • run/set 3 • set up 4 • program 4 • keypad 5–10 • load controls 10–11 • reviewing/revising data 12–17 • programming example 17–19 • battery backup 19 • switching times 20–21 • holiday reference # 22 • holiday switching times 23 • astro and time zones 24–25...

  • Page 2

    Led display the red led display prompts and indicates data as it is entered in set up and program. The display indicates current time in the run mode. Note the dual captions above and below the display. Reset operation begins with reset, followed by data entry with the keypad. Pressing reset initial...

  • Page 3

    Keypad these keys are used for most data entry. Note dual functions, numeric or day specific. Using the day group keys wkdy, wknd and all (for all 7 days) greatly speeds the process. The keypad keys are only functional when the run/set switch is in the set position. Pressing keys when in the run pos...

  • Page 4

    Duration, then press ok. Remember intvl or pulse override is initiated on demand via the keypad and is not based on a day and time, as is normal intvl or pulse. To initiate an override interval or pulse first set the run/set switch to run and set the switch for the desired load to enable, then press...

  • Page 5

    Holiday schedules and dates will remain in timer memory until deliberately cleared. For those holidays whose dates vary from year to year, you must manually revise the start and stop dates (in set up review) annually. Holidays may not be programmed to end before their start date and must end by dec....

  • Page 6

    The green led is on when the normally open contacts are closed. Typical wiring methods will mean that the green led is on when the load is on. Verify this by trial and error if in doubt. If the circuit is on due to an override interval or pulse, the green led will be flashing. When timer power is re...

  • Page 7

    Instructions for reviewing/revising data review procedure • place the run/set switch in the set position to review. • you must review clock info (date, time), astro and holiday dates in set up mode. • you must review all load activity (fixed times, astro times, pulse operations, interval operations ...

  • Page 8

    15 next generation reviewing monday only would immediately give the "end of review"message, indicating no activity, yet there will be activity on monday due to the weekday (8) day group schedule. Therefore, always use the week long review feature for final verification of the complete schedule. Note...

  • Page 9

    • to delete a holiday# (and thus its start/stop dates) that has never had any scheduled on/off times: press set up, then hldy , then the holiday #, then rev, then clear. If the display shows "__", the holiday has been deleted. If "err 22" shows, this holiday has, or once had, a schedule. If so, pres...

  • Page 10

    18 set load slide switches to enable load 1and disable 2 press sat/7, ok (selects saturday only); 7, 5, 0, am, ok (load on time); 1, 2, 0, 0, pm, ok (load off time) scheduled program is now complete. Assume a 30 min. Interval override duration is desired for load 1. Set load slide switches to enable...

  • Page 11

    21 next generation 20 switching times day/day circuits switch on switch off pulse intvl astro group 1 2 override am pm : : n o t i m e e n t r y r e q u i r e d sec : am pm / am pm : : sec : am pm / am pm : : sec : am pm / am pm : : sec : am pm / am pm : : sec : am pm / am pm : : sec : am pm / am pm...

  • Page 12

    Holiday reference # (up to 99 holidays or holiday durations can be programmed) 01 / / 02 / / 03 / / 04 / / 05 / / 06 / / 07 / / 08 / / 09 / / 10 / / 11 / / 12 / / 13 / / 14 / / 15 / / 16 / / 17 / / 18 / / 19 / / 20 / / 21 / / 22 / / 23 / / 24 / / 25 / / 26 / / 27 / / 28 / / 29 / / 30 / / holiday sta...

  • Page 13: Zone 1

    25 vancouver washington montana oregon california nevada utah arizona new mexico texas oklahoma kansas colorado wyoming idaho minnesota iowa illinois wisconsin michigan ohio missouri arkansas louisiana mississippi georgia florida south carolina north carolina w.Va m.D. Del pennsylvania new york mass...

  • Page 14

    Special instructions re-installing logic module carefully plug the 8 wire cable straight into the connector on the rear of the logic module. The sawtooth shape on both connectors must line up to allow the cable connector to be seated. Engage the cut-aways on the right side of the logic module with t...

  • Page 15

    Typical wiring configurations (multi-volt models) warning: if timer power supply voltage is 208/240/277v, you must move the input voltage selector jumper on the power board. See special instructions. 24v models do not have this jumper; connect 24vac 60 hz only to 24v timer power terminals. Circuit #...

  • Page 16

    30 typical wiring configurations (24v models) warning: connect 24vac 60 hz only to 24v timer power terminals. Circuit #1 circuit #2 24 vac timer power 1 2 3 4 5 6 7 8 et70215cr24 2-spdt 24 volt input bell and signal controls / pulse and interval switching (loads and timer powered by same 24 volt sou...

  • Page 17

    32 trouble shooting problem solution(s) display does • make sure flat cable is properly plugged into the not light rear of the logic module. Refer to “re-installing logic module” in special instructions. If connec- tor will not install easily, check for bent pins. • on multi-volt models make sure th...

  • Page 18

    34 problem solution(s) note: astro switching times change daily according to changing sunrise and sunset consider fixed times with this in mind, e.G. A fixed off intended to end an astro on would be ignored if sunset moves beyond the fixed off time. The fixed event should be scheduled to occur outsi...

  • Page 19

    36 problem solution(s) some • all review should be done with only one switching circuit enabled at a time (2 circuit models times don’t only). If both circuits are enabled, only events show during common to both will show during review. To review see all possible scheduled events, the week long revi...

  • Page 20

    Err 22 holiday program must be cleared before clearing holiday number. Err 23 copied to days may be cleared but may not be copied or changed. Err 0a holiday entry not applicable err 0b override entry not applicable err 0c pulse entry not applicable err 0d interval entry not applicable err 0e invalid...