Intermec D5020 Instructions Manual - Ordering Power Cords
MyriadMM
MyriadMM
4
Power Cords, Cables, and Accessories
Y
ou need the following equipment to use the D5020 dock:
•
AC power cord (see the next section)
•
IR transceiver for the D5020 IrDA communications dock
O
r, Intermec null-modem cable (Part No. 070268) for the D5020 RS-232
communications dock
•
(Optional) D5020 Ganging Jumper Kit (Part No. 069600) to connect
multiple docks
Each of these accessories is ordered and purchased separately
. For help,
contact your Intermec sales representative.
Ordering Power Cords
The AC power cord is ordered separately
. If you are using the D5020
Ganging Jumper Kit (Part No. 069600), order one power cord for every
five docks. Otherwise, order one power cord for every dock.
Countr
y
Part Number
Chile and Italy
586282
South Pacific
586281
D
en
m
ar
k
a
n
d
G
re
en
la
n
d
586283
Europe
586267
Liechtenstein and Switzerland
586276
North America and Central America
586105
United Kingdom
586266
Connecting Multiple Docks
The D5020 Ganging Jumper Kit (Part No. 069600) is ordered separately
.
The kit contains four ganging jumpers, four clips, and an instruction
sheet. The ganging jumper links the power between multiple docks and
the clip connects the docks together
. Y
ou use the ganging jumper and
clips to power up to five docks with one power cord.
9
Charging the 502X Batteries
Y
ou can use the dock to char
ge the 502X main battery pack. Y
ou can
charge the battery pack while it is inside the 502X or you can charge an
extra main battery pack in the fast char
ge battery slot. Y
ou should always
have a charged main battery pack in the 502X to prevent the loss of data.
Method of Charging Batter
y Pack
T
ime to Fully Char
ge
Inside the 502X
≤
15 hours
In the fast charge battery slot
≤
4 hours
Use only Intermec battery pack Part No. 068537 in the fast char
ge battery
slot. For help on char
ging the bridge battery
, see the
5020 Data
Collection PC User
’s
Manual
(Part No. 068975) or the
5023 Data
Collection PC User
’s
Manual
(Part No. 070698).
Tr
oubleshooting
If you are unable to establish a good connection with the 502X and the
green Power status light is not lit, you may need to:
•
Set the same serial or IrDA port parameters for the 502X and the serial
or IrDA device.
•
Be sure you have the correct Intermec cable (Part No. 070268) for the
serial communications dock.
•
Ensure that the electrical outlet has power
.
•
Insert the 502X firmly in the dock.
•
Connect the dock to AC power
.
•
V
erify that the circuit breaker on the back of the dock is pushed in.
Circuit
break
er
5020CDIS002.eps