J. A. Roby FORGERON Instruction Manual

Summary of FORGERON

  • Page 1

    March 1 st , 2015 can/ulc s627-m00 ul 1482 can/csa std b415.1-10 instruction manual 490, rue de l'argon quebec, canada g2n 2c9 tel.: 418-849-8095 fax : 418-849-0077 forgeron cuisiniere forgeron.

  • Page 2

    March 1 st , 2015 table of contents introduction .................................................................................. 3 nameplate. .................................................................................. 4 appliance dimensions. ...................................................

  • Page 3

    3 march 1 st , 2015 introduction read all instructions carefully before install your new j. A. Roby wood stove. A good installation is very important for a safe and effective use of j. A. Roby inc stove. In the doubt about the instruction step to install your appliance correctly, we suggest to call ...

  • Page 4

    4 march 1 st , 2015 nameplate..

  • Page 5

    5 march 1 st , 2015 appliance dimensions. Figure 1.

  • Page 6

    6 march 1 st , 2015 installation. Floor protection. Your stove must be installed on a non-combustible material plate to protect the floor and avoid fire would be caused by: • projections of sparks when door opening or loading logs • the heat radiation when stove runaway should have an ignition to th...

  • Page 7

    7 march 1 st , 2015 clearances of the stove until the floor plate protection. The following dimensions are the minimums values and it can be higher. Canada: • 8 in (20.3 cm) behind • 8 in (20.3 cm) beside • 18 in (45.7 cm) in front of the door opening. United states: • 8 in (20.3 cm) behind • 8 in (...

  • Page 8

    8 march 1 st , 2015 minimums clearances to the non-combustible material. With these reduced clearances, this appliance take a minimum of space where is installed. Whether in the living room or the dining room, the cook stove will complete your decorate by his originality and heating, it requires a m...

  • Page 9

    9 march 1 st , 2015 assembly before installation according to chosen option, to save more storage space and shipping. The stove leg and warmer couldn’t be assembled in the shop, you must assembly before install the cooker stove. Legs installation. 1) remove legs and bricks from combustion chamber to...

  • Page 10

    10 march 1 st , 2015 1) fix the left side. 2) fix the right side. 3) fix the front (with the door) with the two sides and the back. Keep the horizontal holes empty for the chrome decoration. 4) insert the chrome decoration in the hole and fix-it with carriage bolt and nut (2 bolts each). 5) fix the ...

  • Page 11

    11 march 1 st , 2015 8) put and fix the warmer with the 6 holes of each side to the cook stove. Fan and snap disc box installation. 1) screw fan putting electrical wire in the centered bottom of both fan. 2) screw snap disc box into the holes made for that at the back side near the vent box. Warning...

  • Page 12

    12 march 1 st , 2015 firebricks installation. Back firebricks installation. 1) put 4 bricks «a» and 1 brick «c» to the middle 2) begin to screw the 3 bricks screws in the hole for this purpose, after insert split washer through the screw and do not tight the screws now 3) add two horizontal bricks «...

  • Page 13

    13 march 1 st , 2015 firebricks installation on the pipes. The firebricks must be put on the 4 pipes from the bottom of combustion chamber. Bricks keep a maximum of heat inside the combustion chamber and help the air ratio to burn the most of wood pollution gas made by wood steam and wet wood. Put t...

  • Page 14

    14 march 1 st , 2015 general stove installation steps. 1) read the entire owner and installation manual before install and use your stove. 2) chose a spot where to install your cook stove. Read section about floor protection dimension and about localisation of stove over the floor protection plate, ...

  • Page 15

    15 march 1 st , 2015 chimney connector installation. The chimney connector is a set of single wall or double wall flue pipes and elbow installed between the stove collar and the chimney collar. The single wall chimney connector is sold into any hardware store and are not homologated and certified. S...

  • Page 16

    16 march 1 st , 2015 3. Insert entirely the roll formed end into the stove collar and screwing it with a minimum of 3 screws. Warning: it is mandatory to screw the pipe to the stove collar and also at each joints with a minimum of 3 screws. 4. Install all the next section up to the roof chimney supp...

  • Page 17

    17 march 1 st , 2015 mobile home installation. Danger: do not install in sleeping room. Warning: the structural integrity of the mobile home floor, wall, and ceiling/roof must be maintained. 1) do the general stove installation steps 1 to 11. 2) the following requirement are mandatory for installati...

  • Page 18

    18 march 1 st , 2015 chimney installation, general steps use only approved chimneys. The same size as the output collar. 6 inches in this case. The chimneys used must be tested according to can/ulc s629 m87 in canada and to ul 103 (type ht) in usa. The cook stove can be install with a masonry chimne...

  • Page 19

    19 march 1 st , 2015 outside vertical installation. The wood appliance must be installed in accordance with the applicable local laws or the can/csa-b365, nfpa211 (usa) norms. Follow the chimney manufacturer’s instructions to install the chimney. Cathedral vertical installation the wood appliance mu...

  • Page 20

    20 march 1 st , 2015 vertical installation the wood appliance must be installed in accordance with the applicable local laws or the can/csa-b365, nfpa211 (usa) norms. Follow the chimney manufacturer’s instructions to install the chimney...

  • Page 21

    21 march 1 st , 2015 external combustion air source. In conventional designed house, natural ventilation is enough to operate the wood stove. In some new energy saving house, natural ventilation is not enough to good operation of your stove. To avoid reverse circulation of smoke caused by negative p...

  • Page 22

    22 march 1 st , 2015 stainless steel deflector replacement. Add-on stainless-steel plate are used into combustion chamber to protect the steel from wear corrosion cause by extreme temperature and extreme conditions into combustion chamber. When it’s too wear they have to be replaced. Back deflector ...

  • Page 23

    23 march 1 st , 2015 stainless steel tubes replacement. Although the tubes are in stainless steel. With extreme temperature and conditions the tubes are eventually corroding and perforating by normal deterioration. They must be replaced by a new one to ensure performance of your stove. Stainless ste...

  • Page 24

    24 march 1 st , 2015 operating instructions primary and secondary air admission control. When the handle on the left side of the stove is vertical the air admission is from the tube only, this is what we called “secondary air admission”. Else when the handle is horizontal the air admission is direct...

  • Page 25

    25 march 1 st , 2015 maintenance. Ash removal. The wood burning make some residual called ash and must be remove from the combustion chamber to help oxygen circulation the ash have to be removed periodically every 2 or 3 days into heavy warming period. Never had excessive accumulation into the combu...

  • Page 26

    26 march 1 st , 2015 the door is the mobile element that need a special attention. Its tightness is primordial. One of the first signs of wear braided fiberglass rope is the white soot seems to stick on the glass located where the air leak. Air tighten adjustment. If the braided fiberglass rope stil...

  • Page 27

    27 march 1 st , 2015 3) align the two fiberglass rope ends and put some high temperature latex between. 4) install the door if you uninstall it what to do in case of chimney fire. Contact your local authority to know what to do in case of chimney fire. And be sure to know procedure in case of chimne...

  • Page 28

    28 march 1 st , 2015 annexe 1 door assembly.

  • Page 29

    29 march 1 st , 2015 annexe 2 parts that can be replaced • bricks • stove ceramic glass • spring handle • stove door • fans • flat fiber glass rope (around glass) • round fiberglass rope • ash plug • slotted brick washer to ordered parts call your stove seller representative..

  • Page 30

    30 march 1 st , 2015 j. A. Roby limited life warranty wood burning stoves & fireplaces j. A. Roby’s warranty only applies to original buyer and is non-transferable. This warranty covers brand new products only, which have not been altered, modified nor repaired since shipment from factory. The produ...