  • Page 1

    1 owner’s manual mystere with or without oven march 9th, 2009 reviewed mystere wood burning stove 490, rue de l'argon, quebec, qc canada (québec) g2n 2c9 phone: 418-849-8095 fax : 418-849-0077 www.Jaroby.Com can/ulc s627-m00 ul 1482.

  • Page 2: Contents

    2 contents warning ......................................................................................................................... 4 notice .............................................................................................................................. 6 c reosote ..............

  • Page 3

    3 carefully read this manual and keep it for further references installation of this appliance must be done by a qualify certified technician and in conformity with the owner's manual guide given with this appliance. The installation must be in agreement with local and national regulations applicabl...

  • Page 4: Warning

    4 warning before installing, please take a few minutes to read this handbook. Keep it in a sure place and easily reachable for future references. Not following these instructions could be a cause of property damages, injuries or death. If this appliance is not properly installed, it could cause fire...

  • Page 5

    5 if the appliance starts to blush, it's because it is too charged. Do not add fuel. Immediately close the doors and the air intake of the appliance until everything becomes normal again. Do not load the appliance beyond the firebricks height. Ashes must be evacuated frequently, put in a steel conta...

  • Page 6: Notice

    6 notice the mystere was conceived to safely function the doors closed and only when burning firewood. Any change, modification or unauthorized installation will automatically cancel the certification of the appliance, its guarantee, its homologation and the appliance might become dangerous. During ...

  • Page 7: Mystere - Specifications

    7 mystere - specifications option with oven without oven combustible wood wood recommended surface 500ft 2 à 1850ft 2 (45.6m 2 à 171.9m 2 ) 500ft 2 à 1850ft 2 (45.6m 2 à 171.9m 2 ) capacity 52 000 btu/h 52 000 btu/h evacuation pipe diameter 6” (15.2cm) 6” (15.2cm) chimney minimal height 12ft (3.7m) ...

  • Page 8: Chimney

    8 chimney only use approved chimneys of the same dimensions as the appliance exit. Therefore, you should use 6 inches diameter chimneys for your mystere. Chimneys must be tested upon the can/ulc s629 m87. The mystere wood appliance can be installed onto a masonry chimney following the ulc s635, ulc ...

  • Page 9

    9 v ertical installation inside a masonry chimney the mystere wood appliance must be installed in accordance with the applicable local laws or the ulc s635, ulc s640, nfpa211 ( usa ) norms. Install the chimney following the manufacturer’s instructions. E xterior vertical installation the mystere woo...

  • Page 10

    10 v ertical installation on a cathedral roof the mystere wood appliance must be installed in accordance with the applicable local laws or the can/csa-b365, nfpa211 ( usa ) norms. Install the chimney following the manufacturer’s instructions. C ross style installation the mystere wood appliance must...

  • Page 11

    11 v ertical installation the mystere wood appliance must be installed in accordance with the applicable local laws or the can/csa-b365, nfpa211 ( usa ) norms. Install the chimney following the manufacturer’s instructions..

  • Page 12: Clearances

    12 clearances due to its reduced clearances, this appliance occupies a minimum of space in the room where it is installed. No matter where you install it, this appliance will perfectly complete your decoration by its originality and its heat. This appliance only needs 8 inches clearance at its back ...

  • Page 13: Seating

    13 seating you must install a fireproof plate under the appliance, which must exceed it of 18 inches at the front, of 8 inches at the sides and of 8 inches at the back. ***use only non-combustible materials such as ceramics, marble or granite. Firebricks place the firebricks as illustrated. They are...

  • Page 14: Fans And Thermodisc

    14 fans and thermodisc the 115 volts fans must be screwed with the grids under the ventilation conduct. The protection thermo disc box must be on the back of the ventilation conduct. Plug the terminal. When the appliance is in function, the heat reaching a temperature of 120 o f activates the thermo...

  • Page 15: Lighting

    15 lighting now that you have completed the installation of the appliance according to the recommendations, you are ready for the lighting! 1. Place papers and small wood in the appliance. 2. Before lighting, be sure that the chimney is warm enough. 3. When the fire is well lit, gradually add bigger...

  • Page 16

    16 before lighting the first fire, clean the gold plated surfaces using a very soft rag moistened with water. Do not use a paper towel to clean it. If they are not erased before the first fire, the fingerprints and other marks could stain these surfaces permanently. In case of a glass replacement: r...

  • Page 17: Warranty

    17 stoves & fireplaces warranty j. A. Roby limited life warranty – wood burning stoves & fireplaces j. A. Roby’s warranty only applies to original buyer and is non-transferable. This warranty covers brand new products only, which have not been altered, modified nor repaired since shipment from facto...