J&M 220 Operating And Maintenance Manual - page 45
MODEL 220
HYDRAULIC
IMPACT HAMMER
IV.
MAINTENANCE AND ADJUSTMENTS
P.
CHARGING
ACCUMULATORS
CAUTION: DO NOT CHARGE (FILL) ACCUMULATORS WITH ANY OTHER GAS
THAN NITROGEN. DO NOT ATTEMPT TO DISASSEMBLE EITHER
ACCUMULATOR WITHOUT REMOVING (VENT) THE ENTIRE GAS
CHARGE.
1. Connect the charging kit (P/N 810833) to a 2000+ PSI (138 Bar) nitrogen gas
bottle.
2. Unscrew the dirt cover from the accumulator gas valve.
3. Connect accumulator adapter assembly (charge kit) to the accumulator, gas
valve, to be charged.
4. Screw in (CW) “T” screw, on accumulator adapter assembly to depress ( open)
the accumulator gas valve.
5. Read the existing accumulator charge pressure on the charge kit gage. See
page V-4 for correct pressures.
6. To increase charge pressure, carefully “crack” open the nitrogen gas bottle
valve until the charge kit gage pressure reaches the specified pressure level.
CAUTION: DO NOT OPEN NITROGEN VALVE RAPIDLY, AS GAS BOTTLE
PRESSURE MAY EXCEED ACCUMULATOR PRESSURE RATING.
7. To decrease charge pressure, open the bleed valve, on the accumulator
adapter, until the charge kit gage reaches the specified pressure level.
8. After the desired charge pressure has been attained, allow the system
temperature to stabilize for 10 to 15 minutes, then recheck the charge pressure.
9. Unscrew the “T” screw, on accumulator adapter assembly to close the
accumulator gas valve.
10. Remove charge kit and re-install the gas valve dirt cover.
IV-12