Jackson MSC DELTA 5 Installation & Operation Manual - page 8
SANITIZER - The run time of the sanitizer dispensing pump
before the rinse sequence which controls the amount of sanitizer
dispensed.
RINSE TANK TEMPERATURE - When the water in the rinse
water booster heater reaches this temperature value, the heating
element will be turned off.
SHUTDOWN AND CLEANING: To turn off the machine, press the
ON/OFF button. The machine will automatically drain (TURNING
OFF will be displayed) and then will turn off (OFF will be dis-
played).
Remove, clean and install the lower wash arm.
Remove, clean and install the four upper spray nozzles.
Remove, clean and install the accumulator strainer.
PRIMING THE CHEMICAL DISPENSING PUMPS: To prime the
chemical feeder pumps that dispense the detergent, rinse aid and
sanitizer chemicals, press and hold the corresponding prime but-
ton on the keypad. The machine must be idle (between cycles) for
these prime buttons to be active.
DELIMING OPERATIONS: The Delta 5 machine has a pre-pro-
grammed delime sequence which will lead the operator through
the steps required to properly delime the machine.
To begin, the machine must be OFF. Press and hold the DELIME
button on the keypad. The machine will automatically fill with fresh
water (FILLING will be indicated on the display). The display will
then indicate to OPEN DOOR - ADD LIME-A-WAY (deliming
chemical agent). Open the doors and add the delime chemical
agent. The display will indicate CLOSE DOORS TO START
DELIME. When the doors are closed, the wash pump will turn on
to circulate the delime agent throughout the machine. At any time,
the doors can be opened in order to inspect the inside of the
machine. The wash pump will restart when the doors are closed.
The display will indicate PRESS DELIME TO STOP CYCLE.
When the DELIME button on the keypad