Jackson R24 Maintenance Instructions

Summary of R24

  • Page 1

    Thermostat replacement 07610-003-12-41 a september 23, 2005 r24/r30 glasswasher maintenance instructions.

  • Page 2

    Jackson glasswasher machines come equipped with ther- mostats to ensure proper ware washing results. Occasionally, some of these components may need replacing to maintain opti- mum performance. Jackson offers all of the repair parts necessary for per- forming this task. The instructions provided her...

  • Page 3

    5. Remove the thermostat from the mounting bracket with the phillipshead screwdriver. 6. Use the 7/16” combination wrench to loosen and remove the imperial brass fitting. Once this is complete, you should be able to completely remove the thermostat. 7. Take the new thermostat and place its probe in ...