    Installation manual models lsl-hcb lsl-hcw limit stat™ is designed to prevent the user from adjusting the temperature beyond a specific heating and cooling limit, thereby greatly reducing utility bills. This installation manual covers both the lsl-hcb single stage, heat / cool battery powered and th...

  • Page 2: Limit Stat™

    Thermostat location turn off power to hvac system .The limit stat™ should be installed in a location that represents the ambient space temperature. Do not install the thermostat in an area where drafts are present, near the floor, behind doors or on an external wall. Avoid placing the thermostat in ...

  • Page 3

    3 single stage heat pump systems for single stage heat pumps, jumper w1 to y1 and wire y1 to the heat pump compressor y terminal. The heat pump reversing valve is configured using one the jumpers located inside the thermostat. (see setup options) when using the lsl-hcb battery powered limit stat™, t...

  • Page 4

    5418 elmwood avenue, indianapolis, in 46203-6025 toll free: 888.652.9663 fax: 317.227.1034 www.Jacksonsystems.Com 8 short cycle protection the limit stat™ has built-in short cycle protection designed to prevent compressor damage due to rapid switching of modes or momentary power outages. Short cycle...