Jacuzzi Select Series Owner's Manual - Troubleshooting Guide
5. Noisy pump and motor.
6. Water leakage at pump shaft
(rotating connection between
pump and motor).
7. Motor will not start.
8. Motor stops.
A. Clean strainers
B. Locate and repair leaks.
C. Tighten fasteners.
D. Add water to normal level.
E *
F. *
G. *
A. *
A. Turn ON power at service panel.
B. Reset circuit breaker.
C. Reset GFCI.
D. Call an electrician or your power
company.
E. *
F. *
G. *
H. *
A. Let cool for one hour. Motor
overload will reset; if problem
persists, see *Note.
B. Consult electrician to correct
wiring to unit.
A. Clogged strainer(s).
B. Leakage of air into suction line.
C. Vibrating parts attached to
motor or support brackets.
D. Low water level.
E. Damaged or worn motor bear-
ings.
F. Impeller rubbing inside case.
G. Debris inside pump.
A. Worn or damaged pump seal.
A. Power OFF.
B. House circuit breaker tripped or
in OFF position.
C. GFCI tripped.
D. Subnormal voltage.
E. Improper or defective wiring.
F. Locked shaft or impeller.
G. Motor windings burned out.
H. Defective starting switch inside
motor.
A. Motor overload condition.
B. Inadequate supply wiring.
TROUBLESHOOTING GUIDE
REMEDY
PROBABLE CAUSE
PROBLEM
*NOTE: The skills and tools necessary for the safe repair of this spa require the services of qualified service
personnel. Contact your Jacuzzi Whirlpool Bath dealer.
15