Jadever JCAII User Manual

Manual is about: Jadever JCAII counting scale User guide

Summary of JCAII

  • Page 1

    V03 jcaii contents 1. Introduction ......................................................................................................... 1 2. Precautions .......................................................................................................... 1 3. Before using the product ........

  • Page 2

    V03 jcaii 8-5 print ......................................................................................................................................... 13 8-5-1 set a print form .............................................................................................................. 13 8-...

  • Page 3

    V03 jcaii 1 1. Introduction thank you for deciding to purchase a jcaii counting scale. This goods has the excellent performance and splendid properties under severe quality management .It is recommended to read this manual in full before using it for good function application. 2. Precautions ◎ p lac...

  • Page 4

    V03 jcaii 2 4. Product introduction 4-1 display 1) weight window: displays weight of object on weighing pan, or accumulated weight value. 2) unit weight window: displays the average piece weight value, or number of weighments . 3) total count window: displays the calculated number of pieces on the w...

  • Page 5

    V03 jcaii 3 stable stable indication, symbol “ ” appears at the top of “stable” when scale is in stable condition. Net gross weight minus tare. Symbol “ ” points at “net” when manual tare or preset are actions are done. 4-2 keypad ·enters specific values for tare, unit weight and other data entries....

  • Page 6

    V03 jcaii 4 ·deletes accumulation records ·display year, date, time ·go back to previous parameter ·recalls and displays the accumulated data ·selects/ sets the hi value of weight or piece ·change the next content of parameter ·selects the lo value of weight or piece ·changes to previous content of ...

  • Page 7

    V03 jcaii 5 parameter description 1. P-00 power (default: off) set the period of inactivity before the scale automatically turns off. Options are off =non power-off, 10, 20,30,40,50, 60, 70, 80 and 90 (minutes). 2. P-01 backlight (default: auto) =always off =always on =turn on when the weight is ove...

  • Page 8

    V03 jcaii 6 7-3 setup 1) under the weighing mode, long press key for 3 seconds to enter basic parameter setting mode. 2) long press key to enter advance parameter setting mode. 3) press key or to select parameter a-08. 4)press key or to step through all the available setting items. = using main scal...

  • Page 9

    V03 jcaii 7 6) press key to save the settings and return to weighing mode. 7-5 calibration = remote platform = main scale note:  please calibrate the main scale first.  press key to switch the calibration for the main scale or remote platform before the zero point calibration.  you can only do th...

  • Page 10

    V03 jcaii 8 5. Press key and wait till is displayed in the total count window. 6. Press key to save the settings and return to weighing mode 7-6 set ad gain of remote platform 1. Under normal weighing mode, press for 3 seconds to enter the basic parameter setting. 2. Press for 3 seconds to enter the...

  • Page 11

    V03 jcaii 9 2. Press key to complete tare action. The symbol appears with symbol pointing at “net”. 3. Put the load on the container. The display shown is the net weight. Press key to see the gross weight. 4. To clear tare, with an empty pan, press key 8-2-2preset tare 1. Input the tare value using ...

  • Page 12

    V03 jcaii 10 2. Use numeric key to input the low limit value. Eg. 0.1kg. 3. Press to save and return. Enable/disable the auto-tare function 1. Under normal weighing mode, press or . Appears in the total count window. (if not press ) 2.If you want to enable auto-tare function, press if you want to di...

  • Page 13

    V03 jcaii 11 8-3-3 acai automatic counting accuracy improvement (acai) results in a more accurate count by increasing the reference weight without the need to count additional parts. A higher reference weight is important when there is a risk of inconsistent piece weights or if the reference weight ...

  • Page 14

    V03 jcaii 12 note: you can change the max accumulation back to 50 times by repeating the above steps. It will beep for 3 seconds when accumulate to the max account (eg. Max accumulation=9) and the is blinking under this condition, you have the following options:  press , it will print every set and...

  • Page 15

    V03 jcaii 13 8-4-5 print while display of accumulation note: only for sh-24 print a certain accumulation enter a certain accumulation display, press print total accumulation enter total accumulation display, press 8-4-6 delete accumulation delete a certain accumulation 1.Enter a certain accumulation...

  • Page 16

    V03 jcaii 14 8-5-2 set print mode 1.Press key with no load on the pan. 2.Press key . The display shown is 3. Press key or to choose the print mode = manual = print after appears = print when quantity is ok(with check function) = print when weight is ok(with check function) = print continuously =no a...

  • Page 17

    V03 jcaii 15 2. Press to save and return. Note: when the serial number reaches the max, the unit weight display will flash and beep for 3 seconds and then return to normal weighing mode. And because it has reached the max serial number, it will reset to 1 when the serial number do increase 1. 8-6-3 ...

  • Page 18

    V03 jcaii 16 2.If you want to enable the function, press if you want to disable the function, press note: when the hi & lo checking function is enabled, there will be an arrow pointing between perset tare and net. 8-8 weight checking 8-8-1set the high limit of weight checking 1.Press under normal we...

  • Page 19

    V03 jcaii 17 perset tare and net. 8-9 unit weight id note: possible save up to 50 id 8-9-1saving id method 1 for example, save 1.23g to id 12 1. Press under normal weighing mode and the unit weight is blinking. 2. Press and key in the accumulation number and the total count window will blinking. 3. ...

  • Page 20

    V03 jcaii 18 3. Press to confirm and the scale is ready for counting. 8-10label set your own label note: the label can save up to 32 characters 1. Keep pressing until you see the display as shown. Arrow “ ” pointing at hi means that the first 16 characters can be edited. 2. Keep pressing and releasi...

  • Page 21

    V03 jcaii 19 8-12 error message =eeprom can not be read =the calibration range can not be read =zero point is too high =zero point is too low =unstable zero point =overload = the last accumulation is more than the preset accumulation allowed. 8-13 problem & solution printer can not print out  make ...

  • Page 22

    V03 jcaii 20 9. Option scale to printer scale to bp545d(tdp) printer scale to sh-24(tp)printer universal 9 pin (male) to 9 pin (male) rs-232 connecting cable. Universal 9 pin (male) to 25 pin (male) rs-232 connecting cable. Scale to zebra printer scale to ez printer universal 9 pin (male) to 9 pin (...

  • Page 23

    V03 jcaii 21 only one optional device being used option application remark ap1 + → can print out bar code bp ap2 2009-05-27 14:46:38 g.W.: 1.000kg u.W.: 0.5g total:400pcs zebra ap3 ez(godex) ap4 + → can print out accumulation data sh-24 ap5 + → only the weighing data can be shown on the led display ...

  • Page 24

    V03 jcaii 22 ap6 + → light tower can indicate three different situation led light tower.

  • Page 25

    V03 jcaii 23 two optional devices being used option application ap1 → bp/ or zebra/ or godex/ or led light tower/ or pc led display.

  • Page 26

    V03 jcaii 24 ap2 bp/ or zebra/ or godex/ or pc.

  • Page 27

    V03 jcaii 25 three optional devices being used option application ap1 → bp/ or zebra/ or godex/ or pc led display and led light tower 10. Relay module diagram relay output: alarm c o m n .C . N .O ..

  • Page 28

    V03 jcaii 26 hi c o m n .C . N .O . Ok c o m n .C . N .O . Lo c o m n .C . N .O . Relay contact spec 1a/24vdc,0.5a/125vac,0.25a/250vdc.