    Compact monochrome megapixel progressive scan camera cv-a1-20 operation manual camera: revision b manual: version 1.1 a1-20manboct08.Doc jpt 08-10-03.

  • Page 2

    Cv-a1-20 table of contents 1. General......................................................................................................... 2 2. Standard composition ....................................................................................... 2 3. Main features ...........................

  • Page 3

    Cv-a1-20 1. General the cv-a1-20 is a monochrome progressive scan 1/2” ccd camera with 1.4 megapixel resolution. Cv-a1-20 is identical to cv-a1, but the pixel frequency is 20 mhz instead of 28.636 mhz. It is designed for automated inspection, featuring a small housing and a wide range of unique func...

  • Page 4

    Cv-a1-20 4. Locations and functions fig. 1. Locations. 1. 12 pin hirose connector for frame grabber interfacing and power (12v dc). 2. Bnc connector for video output. Vs 1.0 vpp 75 ohm. 3. 6 pin hirose connector for trigger input and rs-232c control interface. 4. Gain potentiometer for manual gain s...

  • Page 5

    Cv-a1-20 5. Pin assignment 5.1. 12-pin multi-connector (dc-in/video out, ext.Hd/vd in) type: hr10a-10r-12pb-01 (hirose) male seen from rear. Pin configuration is compatible with eiaj standard fig. 2. 12-pin connector. Plugs for cable: hr10a-10p-12s 5.2. 6-pin multi-connector (trigger) type: hr10a-7r...

  • Page 6

    Cv-a1-20 5.3. Input and output circuits in the following schematic diagrams the input and output circuits for video and timing signals are shown. For alternative connections refer to “7.4. Internal switch and jumper settings.” jumper settings are shown as for factory default. 5.3.1. Video output 300...

  • Page 7

    Cv-a1-20 5.4. Cv-a1 block diagram fig. 8. Block diagram. 6. Functions and operations 6.1. Basic functions some of the primary camera functions need a general introduction before the operation modes are described. The list below shows the primary functions from the command list. Sm shutter mode norma...

  • Page 8

    Cv-a1-20 binning mode bi is a function where the signal charge from 2 or more adjacent pixels are added together and read out as one pixel. A resulting full frame with lower resolution can be read out with a higher rate. By adding 2 pixels together, the sensitivity is doubled. The cv-a1-20 has both ...

  • Page 9

    Cv-a1-20 6.2. Input-output of hd/vd signals in the default setting the camera will accept external hd/vd signals on pin 6 and 7 of the 12 pin hirose connector. If external hd/vd is applied, the camera will synchronize to it. If no external sync signals are applied, the camera will operate with its i...

  • Page 10

    Cv-a1-20 6.3. Continuous operation (non triggered) trigger mode normal. Tr=0. It is for applications where the camera is continuous running without external trigger. In normal mode the shutter mode can be normal or programmable exposure. (sm=0 sm=1). The shutter will work in all 16 steps up to 1/140...

  • Page 11

    Cv-a1-20 6.4. External trigger modes this camera has 6 external asynchronous trigger modes, which can be set by rs-232c commands. 1. Edge pre-select mode.Tr=1 pre-selected exposure. (sm=0, sm=1) 2. Pulse width control mode. Tr=2 pulse width controlled exposure. (hc=0, hc=1) 3. Frame delay read out m...

  • Page 12

    Cv-a1-20 6.5. Edge pre-select mode the exposure starts at the first hd pulse after the trigger leading edge. It stops and is read out after the duration of the shutter time selected. It can be the first 9 step in normal or 1023 steps in programmable shutter. Sm=0 or sm=1. Shutter selections sh ≥10 w...

  • Page 13

    Cv-a1-20 6.6. Pulse width control mode in this mode the exposure starts from the leading edge of the trigger pulse. It stops at the trailing edge of the trigger pulse, and the resulting video is read out. The accumulation can be either h synchronous or h asynchronous. Hc=0 or hc=1. In h synchronous ...

  • Page 14

    Cv-a1-20 6.7. Frame-delay read out mode in this mode the exposure starts from the leading edge of the trigger pulse. It stops at the trailing edge of the trigger pulse. The accumulation can be either h synchronous or h asynchronous. Hc=0 or hc=1. In h synchronous mode the accumulation starts at the ...

  • Page 15

    Cv-a1-20 6.8. Long time exposure mode the exposure time is the interval between 2 external vd pulses sent to the vd input. The exposure starts after the input of a vd, and it ends after the next vd input, which again starts a new exposure. The interval between the external vd pulses (exposure time) ...

  • Page 16

    Cv-a1-20 6.9. Start/stop mode the exposure is controlled by the interval between the external trigger pulse and an external vd pulse. The exposure start at the first hd pulse after the trigger leading edge, and it stops after the rising edge of the vd. An een pulse will indicate the active accumulat...

  • Page 17

    Cv-a1-20 6.10. Smearless mode this mode will reduce the unwanted smear signal from a highlighted scene when a short exposure time is used. The trigger mode is like edge pre-select, but a dummy readout is performed before the active accumulation is started. It will remove the smear above the highligh...

  • Page 18

    Cv-a1-20 6.11. Other functions. Gain and analogue settings. !! Do not adjust these settings unless you have knowledge to video adjustments !! The video gain can be set to agc or manual. In agc mode the video level is kept constant by the automatic gain control circuit within a 12 db range. Normal 70...

  • Page 19

    Cv-a1-20 7.2. Cv-a1-20 rs-232c command list. Command name format parameter remarks a – general settings and useful commands eb echo back eb=[param.] 0=echo off 1=echo on off at power up st camera status request st? Actual setting hp online help request hp? Command list vn firmware version vn? 3 lett...

  • Page 20

    Cv-a1-20 7.3. Camera control tool for cv-a1-20 camera control tool for cv-a1-20 is in principle the same as for cv-a1, only the shutter times are different. From www.Jai.Com cv-a1-20 camera control tool for windows 98/nt/2000 can be downloaded. The control tool contents a camera control program and ...

  • Page 21

    Cv-a1-20 7.4. Internal switch and jumper settings for vd and hd input/output and termination refer to “6.2. Input-output of hd/vd signals.” for alternative connections of pin #10 and #11 on 12-pin connector, jumper jp1, jp2, jp3, jp4 and jp5 can be used. Refer “5.3. Input and output circuits.” jumpe...

  • Page 22

    Cv-a1-20 9. Specifications specifications cv-a1-20 scanning system progressive 1068 lines 11.2 frames/sec. Pixel clock 20.00 mhz line frequency 11.962 khz (1672 pixel clock/line) frame rate for full frame 11.2 frames/sec. (1068 lines/frame) ccd sensor 1/2” progressive monochrome it ccd sensing area ...

  • Page 23

    Cv-a1-20 10. Appendix 10.1. Precautions personnel not trained in dealing with similar electronic devices should not service this camera. The camera contains components sensitive to electrostatic discharge. The handling of these devices should follow the requirements of electrostatic sensitive compon...

  • Page 24

    Cv-a1-20 11. Users record camera type: cv-a1-20 revision: (revision b) serial no. …………….. Users mode settings users modifications declaration of conformity as defined by the council directive 89/336/eec emc (electromagnetic compability) we herewith declare that this product complies with the folowin...