Jandy JPL120100 Installation And Operation Manual

Manual is about: JandyColors Digital Color Blending, Underwater Pool and Spa Lights

Summary of JPL120100

  • Page 1

    H0561200a installation and op er a tion man u al warning for your safety - this product must be installed and serviced by a pro fes sion al pool/ spa service technician. The procedures in this manual must be followed ex act ly. Failure to follow warning notices and instructions may result in propert...

  • Page 3

    Page 3 table of contents section 1. Safety information ................................................................................................................... 4 section 2. Product description and model numbers .................................................................................

  • Page 4

    Page 4 section 1. Safety information important safety instructions pertaining to a risk of fire, electric shock, or injury to persons read and follow all instructions when installing and using this electrical equipment, basic safety precautions should always be followed, including the following: sav...

  • Page 5

    Page 5 section 2. Product description and model numbers product voltage cord length model # jandy pool light 12 volt ac 30 feet jpl1230 jandy pool light 12 volt ac 50 feet jpl1250 jandy pool light 12 volt ac 12 volt ac 100 feet 100 feet jpl12100 jpl12100 jandy pool light 120 volt ac 30 feet jpl12030...

  • Page 6

    Page 6 section 3. Installing jandy light fixture during new construction 3.1 preparing the light fixture for installation note the electrician must complete preparatory steps before light fixture is installed; see figure 1 (or figure 2, for spa). 1. Ensure that the pool or spa meets the requirements...

  • Page 7

    Page 7 2. To be certain that the pool or spa’s electrical system meets all applicable requirements, the electrician should also consult the local building department. 3. Use only approved wet niches (see following note) to ensure a safe and proper installation. Note jandy pool and spa lights are etl...

  • Page 8

    Page 8 5. Coil the 4-foot length of cord around the fi xture and place the light assembly into the niche. 6. Engage the retainer tab on the bottom of the face ring, then pivot the top of the fi xture inward and tighten the special pilot screw. Warning use only the special pilot screw provided with t...

  • Page 9

    Page 9 section 4. Replacing jandy light fixture in an existing pool or spa warning risk of electrical shock or electrocution. This underwater light must be installed by a licensed or certified electrician or a qualified pool or spa serviceman in accordance with the national electrical code and all a...

  • Page 10

    Page 10 note the light fixture may be replaced without removing water from the pool or spa. 1. Turn off the main electrical switch or circuit breaker, as well as the switch, which operates the underwater light. 2. To remove the light assembly, remove the special pilot screw at top of the face ring, ...

  • Page 11: Lights

    Page 11 section 5. Wiring options for controlling jandy pool lights or jandy spa lights note the jandy pool and spa lights will not operate properly with light dimmers. Do not wire the jandy lights to any dimming circuitry. To the extent allowed by code and capacity of the electrical equipment, mult...

  • Page 12

    Page 12 note the jandy pool and spa lights are available in 120-volt and 12-volt versions. If installing a 12-volt light, a 120-volt/12-volt step-down (ac) transformer must be used. For more information about 12-volt installations, refer to section 8 of this manual. Figure 4. 12-volt jandy pool and ...

  • Page 13

    Page 13 section 6. Jandy pool light and jandy spa light operating instructions 6.1 to operate the light turn the light on. The fi rst time the light isturned on, the color change sequence begins with the alpine white color set and then continues through the sequence. The light cycles through 10 colo...

  • Page 14: Section 7. Replacing Bulbs

    Page 14 section 7. Replacing bulbs warning always disconnect power to the pool or spa light at the circuit breaker before servicing the light. Failure to do so could result in death or serious injury to installer, serviceman, pool or spa users or others due to electrical shock. Warning replace all b...

  • Page 15

    Page 15 4. Disassemble the light fi xture and replace bulbs. Use the following bulb removal instructions for jandy pool and spa light: a. A. Loosen the phillips head screw on the band clamp to allow the clamp to be removed. Screw should loosen the phillips head screw on the band clamp to allow the c...

  • Page 16

    Page 16 5. Reassemble the fi xture (applies to both jandy pool light and jandy spa light). A. A. If not already done, remove the gasket from the glass lens and install a new gasket, if not already done, remove the gasket from the glass lens and install a new gasket, jandy pool jandy pool light light...

  • Page 17

    Page 17 section 8. Twelve (12) volt installation a separate 12-volt ac transformer is required on all 12-volt models--for jandy pool light use a 300-watt multi tap 12-volt system. For the jandy spa light, a 100 watt 12-volt system is acceptable. To ensure maximum safety, it is strongly recommended t...

  • Page 18

    Page 18 section 9. Exploded view and replacement parts 9.1 jandy digital pool light 1 2 3 5 4 6 7 8 9 10 figure 7. Jandy digital pool light exploded view dwg# part# description field replaceable 1 n/a pool light housing no - purchase new light 2 n/a transformer (120 volt lights only)-pool no - purch...

  • Page 19

    Page 19 9.2 jandy digital spa light 1 2 3 4 5 6 7 8 9 10 figure 10. Jandy digital spa light exploded view dwg# part# description field replaceable 1 n/a spa light housing no - purchase new light 2 n/a transformer (120 volt lights only)-spa no - purchase new light 3 n/a bulb holder and electronics as...

  • Page 20: Limited Warranty

    Limited warranty thank you for purchasing jandy ® pool and spa products. Waterpik technologies (manufacturer of jandy products, including laars ® pool and spa heaters, air energy heat pumps, and clormatic electronic chlorine generators) warrants all parts to be free from manufacturing defects in mat...