Jandy Laars LT250 Installation And Operation Manual

Manual is about: Gas-Fired Pool and Spa Heater

Summary of Laars LT250

  • Page 1

    For your safety - this product must be installed and serviced by authorized person- nel, qualified in pool/spa heater installation. Improper installation and/or operation can create carbon monoxide gas and flue gases which can cause serious injury, property damage, or death. Improper installation an...

  • Page 2

    Section 1 general information 1a introduction ............................................................ 1 1b description ............................................................. 1 1c warranty ................................................................ 1 section 2 installation instructio...

  • Page 3

    Lx and lt pool heaters page 1 section 1. General information 1a. Introduction this manual contains information for the proper installation and operation of the lx and lt pool/spa heaters. Certain sections are specific to united states or canadian installations, and are labeled united states or canad...

  • Page 4

    Page 2 note: see outdoor installation section regarding roof overhang. These clearances are the minimum acceptable. Whenever possible, larger clearances should be provided to assure adequate room for service operations. Note that gas piping may be provided through either side of the unit. See later ...

  • Page 5

    Lx and lt pool heaters page 3 2d. Outdoor installation the lx and lt heaters can be installed in the outdoor configuration as received from the factory. Locate the heater in an open, unroofed area. Do not install the heater under a deck. Do not locate the heater below or adjacent to any doors, windo...

  • Page 6

    Page 4 inch of flow area for each 4000 btu/h of heater input. If air is provided through horizontal ducts, each opening and duct must provide one square inch of flow area for each 2000 btu/h of heater input. These requirements are summarized in table 2. Note that the specified areas are net free are...

  • Page 7

    Lx and lt pool heaters page 5 1. The gas supply must be able to provide gas at pressures specified in table 5. 2. Gas piping installation must be in accordance with the latest edition of ansi z223.1. In canada, the installation must be in accordance with can- b149.1 or .2 and all local codes that ap...

  • Page 8

    Page 6 b. High altitude (h) - 2,000 to 4,500 feet (610 to 1370 m) for propane gas a. Factory released - 0 to 4,500 feet (610 to 1370 m) 5. Use only wrought steel piping or when permitted by local codes, other rigid piping material. Do not use flexible gas connectors, which restrict gas flow to the h...

  • Page 9

    Lx and lt pool heaters page 7 figure 8. Lld connection/schematic wiring diagram. Caution: do not connect the power of the heater to the "load" or output side of a filter pump relay or time clock. The fan on this heater must have power to run after the filter pump has been shut off. Temp sensor j4-1 ...

  • Page 10

    Page 8 12. Before operating the heater, test the complete gas supply system and all connections for leaks using a soap solution. Do not use an open flame. Caution some leak test solutions (including soap and water) may cause corrosion or stress cracking. Rinse the piping with water after testing. 2g...

  • Page 11

    Lx and lt pool heaters page 9 2. Remove the factory installed jumper wire and tag from the terminal strip (see figure 10). 3. Connect the low voltage wires from the time clock auxiliary switch to the two terminals. Use american wire gage (awg) no. 14 gauge stranded copper wire with a temperature rat...

  • Page 12

    Page 10 3. Remove the two screws holding the bezel in place. Turn the bezel over to view the circuit board on the back. 4. Locate the programmed chip on the power center board (the larger square chip in the lower right corner of the circuit board). In the center of the chip is the revision letter. I...

  • Page 13

    Lx and lt pool heaters page 11 2. Remove the two hex head screws that hold the raceway cover in place. They are located on the bottom flange of the raceway cover. Slide the raceway cover down to expose the raceway. 3. Remove the control panel assembly from the top panel. Lift the control panel cover...

  • Page 14

    Page 12 d. Yellow blower wire to terminal 8 e. White blower wire to terminal 7 31. Reconnect the two white wires to the vent switch now located just above the return header. 32. Reconnect the blower pressure switch tubing to the blower housing. 33. Replace the emi shield (metal plate) located over t...

  • Page 15

    Lx and lt pool heaters page 13 note: only the small tab of the top groove will fit behind the upper panel. 40. Remove the button plug type washer from the left side cover panel. This panel will not be used in reassembling the heater after a heat exchanger reversal. However, the button plug washer wi...

  • Page 16

    Page 14 2i-3. Connections at heater the lx and lt have a standard two inch water header and coupling design. With this feature, only nominal two inch pvc or cpvc may be connected to the heater. However, by installing the appropriate pipe adapters and two short pieces of two inch plastic pipe (suppli...

  • Page 17

    Lx and lt pool heaters page 15 table 6. Chemical concentration levels test recommended level* free chlorine or 1.0 to 3.0 ppm total bromine 2.0 to 4.0 ppm ph 7.2 to 7.6 total alkalinity (ta) 100 to 150 ppm calcium hardness (ch) 200 to 400 ppm langelier saturation index (si) -0.5 to +0.5 cyanuric aci...

  • Page 18

    Page 16 side of the valve. The pressure will be zero when the heater is not running. When the heater is operating the manifold gas pressure should be 4.0" wc for natural gas and 9.0" wc for lp within .2" wc. To adjust the manifold gas pressure, first remove the slotted cap next to the inlet pressure...

  • Page 19

    Lx and lt pool heaters page 17 to adjust the pressure switch, proceed as follows (see figure 19). The pool filter must be clean before making this adjustment. The heater does not have to be firing. 1. Set the heater control to the "off" position. 2. Start the filter pump and confirm by means of an v...

  • Page 20

    Page 18 section 3. Operating instructions lighting and shutdown instructions are posted inside the heater. Do not attempt repairs on the gas control or appliance. Tampering is dangerous and voids all warranties. Lp gas: to avoid possible injury, fire and explosion, read and follow these precautions ...

  • Page 21

    Lx and lt pool heaters page 19 caution figure 21. Temperature control panel laars laars pool/off/spa backlight rs service on line for operation with controller aqualink rs tm laars pool off spa heating service * *service diagnostics-see inside front door f°/c° select thermostat settings low pressure...

  • Page 22

    Page 20 below the backlight indicator is an rs service indicator, which displays ‘rs online’ when the heater is connected to an rs unit. Directly below the rs service indicator on the bottom right hand portion of the lcd screen is the fahrenheit/celsius temperature unit indicator. The model lt does ...

  • Page 23

    Lx and lt pool heaters page 21 lx/lt h eater s ervice d iagnostic g uide d isplay c ode c ause r emedy press sw * (pressure switch) 1. Pump is not running. 1. This is a normal display when the pump is off. No service required. 2. Low pump pressure. 2. Clean filter or clear blockage/check position of...

  • Page 24

    Page 22 then the ignitor will glow and the gas valve will energize. The water temperature and flue temperature will increase as gas combustion takes place. The heater will attempt to ignite three times in succession. If, after three attempts for ignition, the heater does not sense the presence of fl...

  • Page 25: Operating Instructions

    Lx and lt pool heaters page 23 for your safety read before operating warning: if you do not follow these instructions exactly, a fire or explosion may result, causing property damage, personal injury or loss of life. Operating instructions 9. Replace control access panel 10. Turn on all electric pow...

  • Page 26

    Page 24 4. Before entering the spa or hot tub, users should check the water temperature with an accurate thermometer; spa or hot tub thermostats may err in regulating water temperatures by as much as 4f° (2c°). 5. Persons with medical history of heart disease, circulatory problems, diabetes or blood...

  • Page 27

    Lx and lt pool heaters page 25 5. Disconnect the copper tubing from the pressure switch fitting (see figure 24). 6. Cover the vent grille so that snow will not accumulate in the combustion blower, where it may freeze. To reactivate the heater in the spring, have a qualified professional technician r...

  • Page 28

    Page 26 3. Do not use the heater if any part has been under water. Immediately call a qualified professional technician to inspect the heater and replace any part of the control system and any gas control which has been under water. 4. Check for spider webs and other debris in the heater and vent ou...

  • Page 29

    Lx and lt pool heaters page 27 section 5. Parts list 5a. General information to order or purchase parts for the waterpik technologies lx or lt pool/spa heater, contact your nearest waterpik technologies dealer or distributor. If they cannot supply you with what you need, contact the customer service...

  • Page 30

    Page 28 1 (see next page for detail) 6 (see next page for detail) 20 21 22 23 25 (see next page for detail) 44 54 55 57 (see next page for detail) 58 59 60 60 61 63 64 65 66 67 68 69 70 71 72 73 10 9 (see next page for detail) 45 24 62 74 56 36 38 37 5c. Exploded view 5c-1 overview 77.

  • Page 31

    Lx and lt pool heaters page 29 2 3 4 5 7 8 11 11 12 16 17 15 18 19 14 35 27 29 37 42 40 41 52 53 51 32 31 30 34 33 43 43 6 5c-2 detail view 77.

  • Page 32: Limited Warranty

    Limited warranty thank you for purchasing jandy ® pool and spa products. Water pik technologies (manufacturer of jandy products, including laars ® pool and spa heaters) warrants all parts to be free from manufacturing defects in materials and workmanship for a period of one year from the date of ret...