    Installation and operating data installation and operation manual stealth series pumps models shpf and shpm warning for your safety: this product must be in stalled and serviced by a professional service technician, qualified in pool/spa installation. The procedures in this manual must be followed e...

  • Page 3: Table of Contents

    Page 3 table of contents section 1. Important safety instructions ........... 4 1.1 safety instructions .......................... 4 1.2 pool pump suction entrapment prevention guidelines ..................... 6 section 2. General description .......................... 8 2.1 introduction ..............

  • Page 4: Section 1.

    Page 4 section 1. Important safety instructions read and follow all instructions 1.1 safety instructions all electrical work must be performed by a licensed electrician and conform to all national, state, and local codes. When installing and using this electrical equipment, basic safety precautions ...

  • Page 5: Save These Instructions

    Page 5 caution this pump is for use with permanently installed pools and may also be used with hot tubs and spas if so marked. Do not use with storable pools. A permanently installed pool is constructed in or above the ground or in a building such that it cannot be readily disassembled for storage. ...

  • Page 6

    Page 6 1.2 pool pump suction entrapment prevention guidelines warning pump suction is hazardous and can trap and drown or disembowel bathers. Do not use or operate swimming pools, spa, or hot tubs if a suction outlet cover is missing, broken, or loose. The following guidelines provide information fo...

  • Page 7

    Page 7 at least 3 feet suction outlet (main drain) suction outlet (main drain) no valves between tee and main drains listed/certified to ansi/asme a112.19.8 anti-entrapment cover/grate or suction fitting, screw-fastened to main drain sump listed/certified to ansi/asme a112.19.8 anti-entrapment cover...

  • Page 8

    Page 8 section 2. General description 2.1 introduction this manual contains information for the proper installation, operation and maintenance of jandy ® stealth series pumps. Procedures in this manual must be followed exactly. To obtain additional copies of this manual contact us at 707-776-8200, e...

  • Page 9

    Page 9 3.1.3 pipe sizing note all hp ratings given in this section apply to full- rated pumps. For help with max-rated pumps, contact jandy customer service. 3.1.3.1 suction pipe when the pump is located up to 50 feet from the pool, the recommended minimum pipe size for the suction side of the pump ...

  • Page 10

    Page 10 3.2 electrical installation 3.2.1 voltage checks the correct voltage, as specified on the pump data plate, is necessary for proper performance and long motor life. Incorrect voltage will decrease the pump's ability to perform and could cause overheating, reduce the motor life, and result in ...

  • Page 11: Section 4. Operation

    Page 11 3.3 pressure testing warning when pressure testing a system with water, air is often trapped in the system during the filling process. This air will compress when the system is pressurized. Should the system fail, this trapped air can propel debris at high speed and cause injury. Every effor...

  • Page 12

    Page 12 section 5. Service and maintenance 5.1 routine maintenance the pump will collect any large debris present in the water at the pump basket. As debris accumulates it will begin to block the flow of water through the pump, and must be removed. The cleaner the basket is kept, the more effective ...

  • Page 13

    Page 13 section 6. Troubleshooting and repair jandy ® strongly recommends that you call a qualified service technician to perform any repairs on the filter/ pump system. To locate a qualified technician, check your local yellow pages or visit www.Jandy.Com and click on "product support." 6.1 trouble...

  • Page 14

    Page 14 6.2 service technician maintenance warning this pump must be serviced by a professional service technician, qualified in pool/spa installation. The following procedures must be followed exactly. Improper in stal la tion and/or op er a tion can create dangerous electrical hazards which can ca...

  • Page 15

    Page 15 figure 5. Remove the impeller impeller self sealing left handed screw backplate figure 6. Diffuser and impeller exploded view backplate diffuser screws with washers (2) diffuser impeller mechanical seal diffuser o-ring backplate o-ring self sealing left handed screw figure 3. Remove the diff...

  • Page 16

    Page 16 2. Replace the motor shaft cover by inserting the cover tabs into the slots and rotating the cover 90º clockwise. 3. Replace the diffuser over impeller using care to insert alignment pins into the correct holes. The molded-in arrow must point toward the handle of the backplate. 4. Replace th...

  • Page 17

    Page 17 3. Press the new carbon face seal half on the impeller sleeve using a twisting motion. It is very important to grasp the lower portion (opposite the carbon face) when installing the seal or damage to the spring will result. To assist assembly, only water may be used as a lubricant. Any other...

  • Page 18

    Page 18 section 7. Product specifications and technical data 7.1 replacement parts list to order or purchase parts for jandy ® pumps, contact your nearest jandy ® dealer. If they cannot supply you with what you need, contact jandy ® customer service at 707.776.8200 or send an e-mail message to info@...

  • Page 19

    Page 19 figure 10. Shpf and shpm exploded view 7.2 exploded view key no. Part no. Description size (hp) qty. 11 r0446101 tail piece (2" by 2½") coupling nut o-ring .75-2.5 2 2 2 11 r0446102 tail piece (2½" by 3") coupling nut o-ring 3.0 2 2 2 12 r0446200 o-ring, lid all 1 13 r0446300 o-ring, backpla...

  • Page 20

    Page 20 7.3 shpf and shpm pump curves 0.0 20.0 40.0 60.0 80.0 100.0 120.0 0 50 100 150 200 250 0 10 20 30 40 50 feet of head p s i jandy ® stealth series high head pumps full rated (shpf) and max-rated (shpm) flow rate (gpm) 2 hp shpf/ 2.5 shpm 3 hp shpf 1.5 hp shpf/ 2.0 hp shpm 1 hp shpf/ 1.5 hp sh...

  • Page 21

    Page 21 7.4 physical and operational specifications 7.4.1 shpf pump specifications model no. Hp voltage amps pipe size carton weight overall length 'a' shpf.75 .75 208-230/115 6.0-5.6/11.2 2-2½" 43 lbs. 31 7 / 8 " shpf1.0 1.0 208-230/115 7.8-7.4/14.8 2-2½" 45 lbs. 32¼" shpf1.5 1.5 208-230 9.6-8.8 2-...

  • Page 22

    Page 22 shp replacement motor guide pump model a.O smith / century pump model a.O smith/ century shpf .75 b661 n/a n/a shpf 1.0 b841 shpm 1.0 b863se shpf 1.5 b842 shpm 1.5 b864se shpf 2.0 b843 shpm 2.0 b865se shpf 3.0 b844 shpm 2.5 b866se shpm 2.0 2spd b983 shpm 2.5 2spd b984 7.5 replacement motor g...

  • Page 23: Notes

    Page 23 notes.

  • Page 24: Limited Warranty

    Limited warranty thank you for purchasing jandy ® pool and spa products. Jandy pool products, inc. Warrants all parts to be free from manufacturing defects in materials and workmanship for a period of one year from the date of retail purchase, with the following exceptions: • aqualink ® rs units ins...