Janus SHW-MRI-1 User Manual

Manual is about: MACHINE ROOM INTERCOM

Summary of SHW-MRI-1

  • Page 1

    Shw-mri-1 machine room intercom user’s manual shw-mri-1 avire inc 415 oser avenue, suite q, hauppauge, new york 11788 phone: 631 864 3699 toll free: 800 527 9156 fax: 631 864 2631 email: sales.Us@avire-global.Com janus is a brand of avire.

  • Page 2: Table Of Contents

    2 table of contents section page overview 3 installation 4 operation 5 troubleshooting 6 shw-mri-1 connection diagram 7 shw-mri-1 mounting diagram 8 warranty policy 9 return policy 10

  • Page 3: Overview

    3 overview the shw-mri-1 is an easy upgrade solution to provide two- way voice communications between the machine room and the elevator car using an existing ada elevator phone. The shw-mri-1 installs in the machine room, using the existing telephone line that is connected to the ada elevator phone....

  • Page 4: Installation

    4 installation 1. The machine room intercom requires two pair of wires, one for the ada elevator phone and one for the phone line. The shw-mri-1 system requires 24vdc/0.5a to operate. Note: cabling can be inexpensive telephone communication cable, which is normally 20-22 gauge twisted pair. Through ...

  • Page 5: Operation

    5 operation 1. Pickup the handset on the shw-mri-1. 2. Press and hold the push-button on the shw-mri-1 faceplate for at least three seconds. 3. The led on the shw-mri-1 faceplate will start flashing and nothing will be heard through the touchtone phone. The flashing will continue at a faster rate fo...

  • Page 6: Troubleshooting

    6 troubleshooting 1. If the shw-mri-1 does not turn ‘on’ make sure that the wall transformer is plugged into 110vac outlet, and measure the voltage on the “power” connector inside the shw-mri-1 unit. The voltage should read about 24- 28vdc. The “power” connection is not polarity sensitive. 2. If the...

  • Page 7: Figure 1

    7 shw-mri-1 connection diagram figure 1.

  • Page 8: Shw-Mri-1 Mounting Diagram

    8 shw-mri-1 mounting diagram figure 2.

  • Page 9: Warranty Policy

    9 warranty policy avire inc. Warrants its products to be free from defect in materials and workmanship under normal use and service for 24 months from date of purchase. Seller’s obligation shall be limited to repairing or replacing, at its option, free of charge for materials or labor any product wh...

  • Page 10: Return Policy

    10 return policy during installation, if a product does not appear to function properly the installer must call the avire technical support unit at (800) 527-9156, monday through friday. If the technician determines that the product is not functioning, an ra (return authorization) number will be iss...