Jaroby EVOLUTION User Manual - Warning

Summary of EVOLUTION

  • Page 1

    Owner’s manual evolution june 3rd, 2009 reviewed evolution & evolution 2113 490, rue de l'argon, quebec, qc canada g2n 2c9 phone: 418-849-8095 fax : 418-849-0077 www.Jaroby.Com can/ulc_s610-m87 restricted fireguard utilization.

  • Page 2: Table Of Contents

    Table of contents specifications – evolution .................................................................................. 1 warning ......................................................................................................................... 2 notice ..................................

  • Page 3

    Carefully read this manual and keep it for further references. Installation of this appliance must be done by a qualified and certified technician and in conformity with the owner's manual given with this appliance. The installation must be in agreement with local and national regulations applicable...

  • Page 4

    Page 1 specifications – evolution combustible wood recommended surface 0 to 2000 ft² (0 to 186m 2 ) evacuation pipe diameter 6“ (15,24cm) chimney minimal height 15 ft (457,2cm) hot air top exit 6“ (15,24cm) dimensions: glass viewing area (w x h): atc 618 (2 doors) 15” x 12 ¾” ( 38x 32.4cm) evolution...

  • Page 5: Warning

    2 warning before installing, please take a few minutes to read this handbook. Keep it in a sure place and easily reachable for future references. Not following these instructions could be a cause of property damages, injuries or death. If this appliance is not properly installed, it could cause fire...

  • Page 6

    3 be sure that the ashes evacuation cap is closed before lighting. If the evacuation conduct starts to blush, it's because it is too charged. The wood logs shall never stand higher than the firedog in front of the fireplace. Ashes must be evacuated frequently, put in a steel container provided with ...

  • Page 7: Notice

    4 notice your fireplace evolution was tested and approved including supports, firebreak and other chimney components. Any change, modification or unauthorized installation will automatically cancel the certification of the appliance, its guarantee, its homologation and the appliance might become dan...

  • Page 8: Location Of The Fireplace

    5 location of the fireplace - take knowledge of municipal and fire department requirements. - choose a place where you will not have to cut joist. - the fireplace must be installed against a finished wall around the appliance - the top of the fireplace must stay free. - the roof height must be at mi...

  • Page 9

    6 installation of the chimney the minimum height approved for the gas evacuation system is 15 feet and the fireplace is conceived to support up to 25 feet of vertical chimney. For higher, additional supports are required. The authorities require that the chimney has at least 1m (3ft) over the highes...

  • Page 10

    7 intermediate joist entry cf (selkirk cf model) the intermediate joist entry cf is used at any joist level, except on an opened attic. It must be installed from the base to the top with 1 ½ inches screws and should not be cut. A ttic thermal screen installation (jsc, spr, sc-1 and alt models) an is...

  • Page 11

    8 i nstallation of the radiant firebreak (supervent jsc and spr models) the radiant firebreak must be installed where the chimney passes through a floor or a ceiling to another room. The radiant firebreak was tested and approved to be installed over or under the joist. If the radiant firebreak is in...

  • Page 12

    9 i nstallation of the exterior chimney (ss plus, jsc and spr models) for mural installations as illustrated, an intermediate mural support is required immediately over the second elbow, which will support up to 10m (30ft) of chimney. Install a chimney section on the second elbow and fix it with a s...

  • Page 13

    10 cf interior support / deviation support the cf interior support / deviation support can be placed under an intermediate joist entry or an attic isolation protection/firebreak. The interior support stripe of the interior support must be attached under a security bridle and tighten. The straps must...

  • Page 14

    11 3. Slide the roof flashing over the chimney. Place the superior border of the flashing plate under the shingles. Place the two sides and the inferior border over the shingles. See drawing. 4. Square the flashing plate and nail it on the roof by using 12 nails with neoprene rings or cover the head...

  • Page 15

    12 b lowhole systems authorized manufacturer model chimney depth necessary component with the evolution fireplace cheminée sécuritée int. Secure temp s-2100+ 2 attic firebreak ( 6 rsa ) non isolated oliver macleod ht 6000+ 2 attic firebreak ( 6 rsa ) non isolated selkirk metalbestos ltd cf sentinel ...

  • Page 16

    13.

  • Page 17: Exterior Air Canalization

    14 exterior air canalization install the exterior air canalization high enough so that it will not be block by the snow and plan an anti-rodent grid. You should not take the air from a garage, a carport or an attic. Your evolution fireplace can bring exterior air to your fireplace. The maximum lengt...

  • Page 18

    15 internal blower (fans and thermodisc) you can add an internal blower to your evolution fireplace. This kit is a standard at j.A. Roby inc. It includes two fans and a thermocouple lightly noisy and easy to install. The connection must be done by a qualified electrician. The internal and central bl...

  • Page 19

    16 electrical plan of the fans wiring must be done by a qualified electrician..

  • Page 20

    17 w iring must be done by a qualified electrician ..

  • Page 21: Central Blower

    18 blowhole by natural convection blowhole by natural convection can deliver air to a superior level or an adjacent room without needing a blower. This system can be used jointly with optional blowers. Adjust manually the register to your needs. The blowhole system by natural convection can be used ...

  • Page 22

    19 the evolution fireplace has two air exits on the top of the appliance. When you want to plug the central blower, use the left exit (when you face the fireplace). The right one is only for the blowhole by natural convection. The fan system must not end in the attic. O to begin the installation of ...

  • Page 23

    20 installation of the 460 cfm fan 6.

  • Page 24

    21.

  • Page 25: Extrusion

    22 extrusion your evolution fireplace is delivered with an extrusion which allows a good quality of finishing and is easy of installation. When the gypsum wall is finished, you only have to slide the extrusion on each side of the fireplace. Then, insert the superior part and the finishing is complet...

  • Page 26: Doors Adjustment

    23 doors adjustment your evolution fireplace is a model with two cast iron doors. Each door can be adjusted (height, width and depth). To adjust, unscrew the four nuts, close the left door first then the right one. Adjust the arc over the doors to align it and the centre of the two doors. Firmly mai...

  • Page 27: Lighting

    24 lighting before lighting the first fire, be sure to clean every dirt or fingerprints if you don't want to permanently mark your fireplace. To light a fire, place newspapers and small wood. Then, add small wood logs. Light the fire and let the door slightly open. Once the fire is well lit, add big...

  • Page 28

    25 preventive measures and maintenance verify the accumulation of creosote every week that you use the appliance until you know at which frequency it must be cleaned (minimum once per year). Remove every creosote deposit in order to prevent chimney fires. A sweeping is recommended if there is an acc...

  • Page 29

    26 in case of a glass replacement: • remove the screws and supports retaining the glasses. • remove the broken glasses. • envelope the frame of the new glass with a fibre glass joint. • replace the glass. • replace the screws and the support. R eplace the broken glasses by vitroceramics glasses of 5...

  • Page 30

    27 - register (rcn) - starting collar (atccd) - back draft (atcvar) - control rod (trcn) - collar / extending union kit (atcup) - inversed thermostat (atct) - exit adaptor (atcas) - front frame (atccf1 ) (atccf2 ) (atccf3 ) - blinds (atcpero) (atcperc) (atcpern) (atcpere) - cast iron door (evpn) (ev...

  • Page 31: Warranty

    28 stoves & fireplaces warranty j. A. Roby limited life warranty – wood burning stoves & fireplaces j. A. Roby’s warranty only applies to original buyer and is non-transferable. This warranty covers brand new products only, which have not been altered, modified nor repaired since shipment from facto...

  • Page 32

    29.