    490, rue de l'argon quebec (québec) g2n 2c9 phone: 418-849-8095 fax : 418-849-0077 www.Jaroby.Com owner’s manual ultimate ultimate-b high efficiency wood stove revised december 04, 2013 ultimate and ultimate-b certified and tested according to ul-1482-00 and ulc-s627-00 norms..

  • Page 2: Table Of Contents

    2 table of contents warning ...............................................................................................................................................3 notice ...........................................................................................................................

  • Page 3: Warning

    3 warning before installing, please take a few minutes to read this handbook. Keep it in a sure place and easily reachable for future references. If this appliance is not properly installed, it could cause fire damages to the property, injuries and death. To reduce fire hazards, follow instructions ...

  • Page 4

    4 ashes must be evacuated frequently, remove it with a small steel shovel. Very hot while in operation. Keep the children away. Can cause burns by contact. Considering the need of air for the combustion, a window or a door must be half opened sometimes (fresh air drainage) to balance the pressure in...

  • Page 5: Notice

    5 notice the ultimate was conceived to safely function the doors closed and only when burning firewood. Any change, modification or unauthorized installation will automatically cancel the certification of the appliance, its guarantee, its homologation and the appliance might become dangerous. During...

  • Page 6

    6 specifications - ultimate and ultimate-b combustible wood recommended surface 500 à 3000 ft² (46,5 à 278,70 m²) evacuation pipe diameter 6 in (15,24 cm) chimney minimal height 12 ft (3,66m) dimensions exterior height 35.8 in. (90,9 cm) exterior width 27,5 in. (70,0 cm) exterior depth 37 in. (94 cm...

  • Page 7: Installation

    7 installation a good installation is extremely important for a safe and efficient use of your j. A. Roby inc. Appliance. If you doubt on the way to install the appliance correctly, seek for professional installation service. We suggest you to call masters fitters. 1. Withdraw firebricks placed insi...

  • Page 8

    8 v ertical installation inside a masonry chimney the ultimate and ultimate-b models must be installed in accordance with the applicable local laws or the can/csa - b365 ulc s635, ulc s640, ul 1777 norms. For the chimney, follow the chimney manufacturer's instructions. E xterior vertical installatio...

  • Page 9

    9 v ertical installation on a cathedral roof the ultimate and ultimate-b models must be installed in accordance with the applicable local laws or the can/csa - b365 ulc s635, ulc s640, ul 1777 norms. For the chimney, follow the chimney manufacturer's instructions..

  • Page 10

    10 c ross installation the ultimate and ultimate-b models must be installed in accordance with the applicable local laws or the can/csa - b365 ulc s635, ulc s640, ul 1777 norms. For the chimney, follow the chimney manufacturer's instructions. V ertical installation the ultimate and ultimate-b models...

  • Page 11: Clearances

    11 clearances due to its reduced clearances, this appliance occupies a minimum of space in the room where it is installed. No matter where you install it, the ultimate and ultimate-b models will complete perfectly your decoration by their originality and their heat. With the addition of a heat shiel...

  • Page 12: Floor Protector

    12 floor protector your wood stove should be placed on a non-combustible plate under the appliance, which must exceed 18 inches to the front, 8 inches on each side and 8 inches to the back. *** only use non-combustible materials. Ex : (ceramic, marble, granite).

  • Page 13: Door Adjustment

    13 door adjustment in order for your stove to operate properly, the door should be adjusted using the small wrench tool to provide an air tight fit: to adjust: turn clockwise until the door is air tight. Lighting now that you have completed the installation of the appliance according to the recommen...

  • Page 14: Fans And Thermodisc

    14 fans and thermodisc the 115 volts fans must be screwed with the grids beneath the air corridor. The thermo disc box must be screwed on the back of the corridor. Connect the thermo disc into the electrical outlet. When the appliance is in function, the heat reaching a temperature of 120 o f activa...

  • Page 15

    15 preventive measures and maintenance 1. We recommend opening the air intakes completely and to maintain an intense fire from 10 to 20 minutes per day or use a chimney thermometer, as flue gases should reach at least 350° f before closing the air intake. 2. Verify the accumulation of creosote every...

  • Page 16: Replacement Part L Ist

    16 replacement part l ist • bricks • wool • plates used to retain wool • pipes • glass • bricks supports • door handle • fans • cords * t o order parts , please contact your authorized retailer ..

  • Page 17

    17 installation of the firebricks 1. Before you begin, please take note that the purpose for the screws is to secure the bricks inside the stove. 2. First, install the bricks c (10), f (2), e (1) at the bottom of the stove and c (1) & d (1) on the inclined part near the door. 3. Second, install the ...

  • Page 18

    18 figure 1 . 0

  • Page 19

    19.

  • Page 20: Warranty

    20 stoves & fireplaces warranty j. A. Roby limited life warranty – wood burning stoves & fireplaces j. A. Roby’s warranty only applies to original buyer and is non-transferable. This warranty covers brand new products only, which have not been altered, modified nor repaired since shipment from facto...