Jasic TIG180 Operator's manual

Manual is about: TIG Series DC MMA / TIG Welding machines

Summary of TIG180

  • Page 1

    Wilkinsonstar.Com tig series dc mma / tig welding machines order code ! Tig180 ( jt-180 / tig200 (jt-200 ) ! ! ! ! Tig180 ( jt-180dv / tig200 (jt-200dv ) operator manual.

  • Page 2: Your New Product

    Your new product thank you for selecting this jasic technology, wilkinson star product. This product manual has been designed to ensure that you get the most from your new product. Please ensure that you are fully conversant with the information provided paying particular attention to the safety pre...

  • Page 3: Safety Precautions

    Safety precautions 1 these general safety norms cover both arc welding machines and plasma cutting machines unless otherwise noted. The equipment must only be used for the purpose it was designed for. Using it in any other way could result in damage or injury and in breach of the safety rules. Only ...

  • Page 4

    Do not weld on coated metals, unless the coating is removed from the weld area, the area is well ventilated, and while wearing an air-supplied respirator. The coatings on many metals can give o ff toxic fumes if welded. Prevention against burns and radiation arc rays from the welding process produce ...

  • Page 5

    Rf declaration equipment that complies with directive 2004/108/ec concerning electromagnetic compatibility (emc) and the technical requirements of en60974-10 is designed for use in industrial buildings and not those for domestic use where electricity is provided via the low voltage public distributi...

  • Page 6: Product Overview

    Product overview 2 the unique electronic structure and air channel design in this series of machines provides e ffi cient cooling of the power devices as well as improving the duty cycles of the machines. The design of the forced air-cooling system channel can e ff ectively prevent the power devices an...

  • Page 7: Technical Data

    Technical data 3 tested at the environment temperature of 40 0 c product design may vary due to customer requirements. 6 technical parameter technical parameter unit model model model model model model technical parameter technical parameter unit tig180 (jt-180) tig 200 (jt-200) tig180dv (jt-180dv) ...

  • Page 8: Controls

    Controls 4 front view 1. Overheating led to indicate overheating. 2. Power led to indicate the power is on. 3. Downslope time control: 1~10s. 4. Post-flow time control: 1~10s. 5. "+" output terminal: to connect the work clamp. 6. "-" output terminal: to connect the tig torch. 7. Torch switch plug co...

  • Page 9: Installation

    Installation 5 unpacking check the packaging for any signs of damage. Carefully remove the machine and retain the packaging until the installation is complete. Location the machine should be located in a suitable position and environment. Care should be taken to avoid moisture, dust, steam, oil or c...

  • Page 10: Operation

    Operation before starting any welding activity ensure that you have suitable eye protection and protective clothing. Also take the necessary steps to protect any persons within the area. Mma after connecting the welding leads as detailed you will need to switch the power switch on the back panel to ...

  • Page 11

    Electrode type the corresponding relationship between gas nozzle diameter and electrode diameter tig of stainless steel (single run welding) for welder training please visit our academy website at www.Wilkinson-welding-academy.Com 10 type mode colour thoriated 2% dc welding of steel, stainless steel...

  • Page 12

    Maintenance and troubleshooting 6 the following operation requires su ffi cient professional knowledge on electric aspects and comprehensive safety knowledge. Make sure the input cable of the machine is disconnected from the electricity supply and wait for 5 minutes before removing the machine covers....

  • Page 13

    12 symptom cause solution difficult to ignite the arc the arc ignition current is too low or the arc ignition time is too short. Increase the arc ignition current or prolong the arc starting time. No arc can be started phase failure of the mains power supply or the mains supply cable is not connecte...

  • Page 14: Electrical Schematic

    Electrical schematic 7 13.

  • Page 15: Parts List

    Parts list 8 14.

  • Page 16

    15 no. Part no description no. Part no description 1 10004949 power switch 22 10041436 thermal switch 2 10041432 power line 23 10037134 switching mode power supply transformer 3 10042342 connector for input gas 24 10006477 12v electric relay 4 10044817 tig180/tig180 dual voltage fan 25 10037146 top2...

  • Page 17: Order Code

    Jt dc tig series dc tig/mma welding machine order code ! Tig180 ( jt-180 / tig200 (jt-200 ) ! ! ! ! Tig180 ( jt-180dv / tig200 (jt-200dv ) © wilkinson star limited issue 1 january 2014 product is subject to change without notice xvi.