Jaspi Nordic 12 User Manual

Manual is about: Air/water heat pump

Summary of Nordic 12

  • Page 1

    User manual lek jÄspi inverter nordic 8, 12, 16, 20 air/water heat pump uhb en 1817-2 331844.

  • Page 3: Table Of Contents

    Table of contents 4 1 important information 4 installation data 5 safety information 6 symbols 6 marking 7 serial number 7 jÄspi inverter nordic – an excellent choice 9 2 the heat pump – the heart of the house 9 heat pump function 11 control of jÄspi inverter nordic 12 maintenance of jÄspi inverter ...

  • Page 4: 1 Important Information

    1 important information installation data jÄspi inverter nordic product serial number installation date installer serial number must always be given. Certification that the installation is carried out according to instructions in kaukora's installer manual and applicable regulations. _______________...

  • Page 5: Safety Information

    Safety information this appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand ...

  • Page 6: Symbols

    Symbols note this symbol indicates danger to person or machine . Caution this symbol indicates important information about what you should observe when maintaining your installation. Tip this symbol indicates tips on how to facilitate using the product. Marking the ce mark is obligatory for most pro...

  • Page 7: Serial Number

    Serial number the serial number can be found at the top left on the rear cover and at the bottom on the side. F2120 serial number caution you need the product's (14 digit) serial number for servicing and support. JÄspi inverter nordic – an excellent choice jÄspi inverter nordic is an air/water heat ...

  • Page 8

    ■ fan jÄspi inverter nordic has automatic capacity regulation of the fan. ■ long service life the material has been chosen for a long service life and is designed to withstand the nordic outdoor conditions. ■ many possibilities jÄspi inverter nordic is intended for combination with the indoor module...

  • Page 9: The House

    2 the heat pump – the heart of the house heat pump function värmebärare köldmedium uteluft förångare kondensor 80 °c 2 °c -3 °c 5 °c 0 °c 55 °c 45 °c expansionsventil kompressor a d f h i b c e g heating medium värmebärare köldmedium köldbärare värmekälla förångare kondensor 100 °c 0 °c -3 °c -2 °c ...

  • Page 10

    An air/water heat pump can use the outdoor air to heat up a home. The conversion of the outdoor air’s energy to residential heating occurs in three different circuits. In the brine circuit (1), free heat energy is retrieved from the surroundings and transported to the heat pump. The heat pump increa...

  • Page 11

    Control of jÄspi inverter nordic the heat pump is controlled in various ways depending on your system. You control the heat pump via your indoor module jÄspi theowatti air or control module jÄspi_mcu40. See the relevant manual for more inform- ation. During installation, the installation engineer ad...

  • Page 12: Regular Checks

    Maintenance of jÄspi inverter nordic regular checks when your heat pump is located outdoors some external maintenance is required. Note insufficient maintenance can cause serious damage to jÄspi inverter nordic, which is not covered by the guarantee. Checking grilles and bottom panel on jÄspi invert...

  • Page 14: Silent Mode

    Cleaning the outer casing if necessary the outer casing can be cleaned using a damp cloth. Care must be exercised so that the heat pump is not scratched when cleaning. Avoid spraying water into the grilles or the sides so that water penetrates into jÄspi inverter nordic. Prevent jÄspi inverter nordi...

  • Page 15

    Updating the software in jÄspi inverter nordic via the control module or indoor module the latest software for both jÄspi inverter nordic and the indoor mod- ule/control module can be found at www.Myupway.Com. Click the "software" tab to download the latest software for your installa- tion. Save the...

  • Page 16: Saving Tips

    Caution software for the indoor/control module must be updated when software for outdoor module jÄspi inverter nordic is updated. Caution it can take up to 30 minutes to update the software for jÄspi inverter nordic. Caution restart the indoor module/control module to see the correct version number ...

  • Page 17

    Power consumption energiförbrukning fördelat över året jan feb mars april maj juni juli aug sep okt nov dec månad % av årsförbrukningen 0% 5% 10% 15% 20% 25% the air/water heat pump's energy distribution spread across the year month jan feb mar april may june july aug sep oct nov dec % of annual con...

  • Page 18

    Appr. Ann. Con- sump (kwh) normal output (w) equipment 380 - 120 freezer (operation: 24 h/day) 365 - 1500 stove, hob (operation: 40 min/day) 310 - 3000 stove, oven (operation: 2 h/week) 730 - 2000 dishwasher, cold water connection (opera- tion 1 time/day) 730 - 2000 washing machine (operation: 1 tim...

  • Page 19: 3 Disturbances In Comfort

    3 disturbances in comfort troubleshooting note work behind covers secured by screws may only be carried out by, or under the supervision of, a qualified installation engineer. Tip jÄspi inverter nordic communicates all alarms to the indoor module/con- trol module (jÄspi tehowatti air / jÄspi mcu40)....

  • Page 21: 5 Glossary

    5 glossary additional heat the additional heat is the heat produced in addition to the heat supplied by the compressor in your heat pump. Additional heaters can be for ex- ample, immersion heater, electric heater, solar power system, gas/oil/pellet/wood burner or district heating. Ambient temperatur...

  • Page 22: Condenser

    Condenser heat exchanger where the hot gas state refrigerant condenses (cooled and becomes a liquid) and releases heat energy to the house heating and hot water systems. Cop if a heat pump has cop of 5, this means that you only pay for a fifth of your heating demand. This is the efficiency of the he...

  • Page 23: Expansion Valve

    Expansion valve valve that reduces the pressure of the refrigerant, whereupon the temper- ature of the refrigerant drops. Expansion vessel vessel with heating medium fluid with the task of equalising the pressure in the heating medium system. Fan during heating operation, the fan transports energy f...

  • Page 24: Refrigerant

    Refrigerant substance that circulates around a closed circuit in the heat pump and that, through pressure changes, evaporates and condenses. During evap- oration, the refrigerant absorbs heating energy and when condensing gives off heating energy. Return pipe the line in which the water is transport...

  • Page 25: Item Register

    Item register b basic actions, 19 c control module's function, 9 control of jÄspi inverter nordic, 11 d disruptions to comfort basic actions, 19 disturbances in comfort, 19 troubleshooting, 19 g glossary, 21 h heat pump function, 10 i ice build-up in the fan, grille and/or fan cone, 19 important inf...

  • Page 28

    Ws name: -gemensamt ws version: a497 ws release date: 2018-03-26 11:21 publish date: 2018-04-18 12:53 kaukora oy pl 21, tuotekatu 11 212 01 raisio +358 2 437 4600 e-mail: kaukora@kaukora www.Kaukora.Fi 331844.