Jaspi TRIPLEX Installation And User Manual

Manual is about: Multifuel boilers

Summary of TRIPLEX

  • Page 1

    Us e r manual i nstallation and j a s p i k n o w s h e a t i n g multifuel boilers jaspi triplex www.Jaspi.Uk.

  • Page 2: Table Of Contents

    Table of contents technical data ......................................................................................2 boiler installation .............................................................................3 general instructions ..............................................................

  • Page 3

    2 - combined mano-thermometer - grate parts: 2. Cold water inlet ø22 mm 6. Fire management hatch 7. Air valve (primary air) 8. Filling hatch 9. Air valve (secondary air) 11. - 13. Burner hatch 18. Heating output 19. Heating return 20. Adjustment panel 21. Burner thermostat 23. Thermometer 24. Manome...

  • Page 4

    3 general installation instructions - install the boiler in an upright position on an incombustible surface in a dry boiler room. - observe sufficient installation and maintenance space around the boiler. - boiler connections to the network are done so that the piping is not strained. - install nece...

  • Page 5

    4 heating system the boiler’s standard equipment includes a 4-way mixing valve which is connected to the flange on top of the boiler. The pipe entering the radiator network is connected to the left (seen from the front) and the return pipe to the right side of the valve. The temperature of the outfl...

  • Page 6

    5 boiler introduction when introducing the boiler, it should be ensured that the system is filled with water and air is removed. The tightness of the piping should also be checked to avoid leaking damage to the system. The manometer must be observed in conjunction with the usage of the apparata. In ...

  • Page 7

    6 boiler usage oil usage the burner control thermostat is set in the proximity of 75 ° c or higher, thus producing more hot figure 3. Oil side 1. Oil side cleansing hatch 2. Wood/oil side cleansing hatch 3. Burner hatch with flame observation glass 4. Exit gas control (1 piece) maintenance when the ...

  • Page 8

    7 burning wood by brushing and scraping off the accumulated smut through the cleansing and filling hatches. • pull the firing throat out of the boiler furnace • open the air dampers of the holes. And remove ash that has remained from previous burning. After removing ash, push the firing throat back ...

  • Page 9

    Combustion air adjustment (wood heating) with clean convection surfaces in the boiler, the flue gas temperature must be approx. 170-250°С depending on the wood quality and the draft in the flue duct. The air amount and ratio required for burning has therefore to be adapted to the wood type and draft...

  • Page 10

    General guidelines leaks in the piping. The boiler can easily overheat in firewood usage. This can cause the burner or resistor temperature limiter to go off. Once the boiler has somewhat cooled off (temperature approx. 80 °c), the released temperature limiter can be retuned by pressing the temperat...