Jaycar Electronics MP5212 User Manual

Manual is about: Rack Mount Series

Summary of MP5212

  • Page 1

    Ups rack mount series (1-3kva) user’s manual.

  • Page 2: 【Note】

    【note】 please carefully read the user’s manual before operation for the sake of understanding correct operation of the instrument. Please keep the manual handy for future reference. Warning the input and output of the instrument is with danger high voltages which may endanger the safety of life. Ple...

  • Page 3: Contents

    -i- contents 1.Overview .......................................................................................................................................... 1 1.1 profile ..............................................................................................................................

  • Page 4

    -ii- 4.5 battery changing ................................................................................................................... 19 4.6 maintenance guide ................................................................................................................ 19 4.6.1 safety prec...

  • Page 5: 1.Overview

    Rack mount series ups (1~3kva) user ‘s manual -1- 1.Overview 1.1 profile rack mount (1-3kva) series ups are total high frequency, pure online and intellectualized ups. They are also ideal power guarantee for file server, enterprise server, central server, microcomputer, concentrator, telecommunicati...

  • Page 6

    Rack mount series ups (1~3kva) user ‘s manual -2- 1.2 performance index the main performance index of 1-3kva series is shown in table 1-1. Table 1-1 ups main performance index index model 1kva 2kva 3kva input charact eristic rating voltage (v) in range 160v~290v full load, 50% load even voltage low ...

  • Page 7

    Rack mount series ups (1~3kva) user ‘s manual -3- 1.3 primary functions and characteristics 1. intelligent rs232 communication function: with rs232 standard data interface and ups power management software, realize three remote-control functions between computer and ups, computer supervises ups oper...

  • Page 8

    Rack mount series ups (1~3kva) user ‘s manual -4- 2. protective ground terminals should be connected to earth end for sure. 3. high leakage danger! Connect to the ground before connecting ups. 4. install this ups indoors with both temperature and humidity under control and without dust. 5. the elect...

  • Page 9

    Rack mount series ups (1~3kva) user ‘s manual -5- 2 .Structure and basic principles 2.1 general structure this series ups 1~3kva have led or lcd display for choice. And they could be used as tower and rack mount type ups 2.1.1 1~3kva series front panel structure 1~3kvaseries ups front panel have led...

  • Page 10

    Rack mount series ups (1~3kva) user ‘s manual -6- input dc fuse 250v/10a ac input ac output 10a max. Ac output 10a max. Signal rs232 rs232 usb sn mp n e ta ge nt m ini these communication interfaces are optional rs232&dry contact(db9) rs232 rs232&usb snmp american socket 2 3 4 5 6 1 rs 23 2 ac outpu...

  • Page 11

    Rack mount series ups (1~3kva) user ‘s manual -7- input dc signal rs232 rs232 usb sn mp net a gen t m ini these communication interfaces are optional rs232&dry contact(db9) rs232 rs232&usb snmp 5 2 3 3 4 these input and output modules are optional fuse 250v/15a ac input pe l n ac output 10a max. Fus...

  • Page 12

    Rack mount series ups (1~3kva) user ‘s manual -8- shock. 2. Dc port. One port is used for ups dc input, another port is used for parallel battery pack. 3. Nut for connecting ground. Connect to ground when using. 4. Breaker 2.1.4 1~3kva series rack mount and tower structure 1~3kva series rack mount a...

  • Page 13

    Rack mount series ups (1~3kva) user ‘s manual -9- 2.2 basic principles when commercial power is normal, rack mount series ups input, through pfc, increases the voltage to ±360v stabilized dc voltage, which supplies dc/ac inverter and transmits stable 220v ac, while at the same time completing the ch...

  • Page 14

    Rack mount series ups (1~3kva) user ‘s manual -10- table 2-1 corresponding relations of pins for the rs232 serial ports of this series ups and those of general pc : communication rs232 interface for ups general rs232 interface 9 (3) 2 (receive) 6 (2) 3 (deliver) 7 (5) 5 (ground) dry contact communic...

  • Page 15: 3 .Equipment Installation

    Rack mount series ups (1~3kva) user ‘s manual -11- 3 .Equipment installation (删除上面一空白页) 3.1 site and environment requirements before ups installation, the site and environment of equipment room should meet the essential conditions for safe and normal operation of equipment as defined in this section...

  • Page 16

    Rack mount series ups (1~3kva) user ‘s manual -12- 3.2 procedures of dismantling cases when installing the equipment, the packing should be removed after carrying the equipment to the installation site. The packing of ups equipment and fittings (battery, etc.) should be wooden case and carton. Check...

  • Page 17

    Rack mount series ups (1~3kva) user ‘s manual -13- 1.place ups on flat floor (avoid oblique and ragged floor). 2.keep good ventilation, the distance of the back and side to the wall should be above 30cm~50cm, to facilitate heat emission. 3.avoid placing it in the location with sunshine, rain and dam...

  • Page 18

    Rack mount series ups (1~3kva) user ‘s manual -14- table 3-2 recommended sectional flow of cable sectional area of ups ampacity (a) sectional area (mm 2 ) 1 1.5 2.5 4 6 10 16 25 rubber (25°c) 8 12 20 28 42 70 96 125 plastic (25°c) 6 9 15 20 30 50 64 100 3.5 cable connection to connect ups cable only...

  • Page 19

    Rack mount series ups (1~3kva) user ‘s manual -15- battery cabinet installation and battery cabinet cable connections please refer to the installation manual. Step 3. For the long backup type ups, the battery connecting line could be connected with ups only after the ups with mains input picture sho...

  • Page 20

    Rack mount series ups (1~3kva) user ‘s manual -16- normative. Whether the wire diameter of ac input cable is suitable. Whether control switch is connected outside. Whether the connection of line wires (l), neutral wire (n) and ground wire (pe) is correct. Whether the connection of ac input wire is f...

  • Page 21

    Rack mount series ups (1~3kva) user ‘s manual -17- 4 . Equipment use and maintenance 4.1 preparations before first start-up to ensure normal operation of ups, please confirm the following before use: 1. Correct installation of input and output; 2. If the power end is connected to rated input power s...

  • Page 22

    Rack mount series ups (1~3kva) user ‘s manual -18- 3. normally, only when the ups has been started and is working stably, can the loading equipment power switch be turned on. First turn on high-power equipment, then the equipment with lower power. Some equipment has large start current (such as moni...

  • Page 23

    Rack mount series ups (1~3kva) user ‘s manual -19- 9. when not using ups, please turn off the "power" switch on the panel to avoid causing long-time battery discharge after commercial power failure. If the ups has not been used for a long time, regularly perform charging and discharging of battery t...

  • Page 24

    Rack mount series ups (1~3kva) user ‘s manual -20- 3. when operate ups, do not wear gold or silver jewelry such as ring or watch, etc. 4. do not take the safety operation procedure for granted. If there is any doubt, consult personnel who are familiar with the equipment. 5. be cautious that there is...

  • Page 25

    Rack mount series ups (1~3kva) user ‘s manual -21- cause: wrong connection of three ups input wires, for example, zero line or fire wire is connected to ups earth wire (case); or wrong connection of three ups output wires. Problem 3 after ups is started, it outputs ac 220v, yet it's working under by...

  • Page 26

    Rack mount series ups (1~3kva) user ‘s manual -22- after working for a certain period, with normal input display, the buzzer gives intermittent buzzing and displays battery low-voltage simultaneously. Cause: too-low power grid voltage makes the ups work under battery feed status. When the battery ru...

  • Page 27

    Rack mount series ups (1~3kva) user ‘s manual -23- (3) poor contact between battery connecting wires or connecting terminals. 3.intermittent buzzing of the buzzer when ups input is normal. Possible causes: abnormal input voltage that exceeds the ups' allowable input voltage range of power supply. 5....

  • Page 28

    Rack mount series ups (1~3kva) user ‘s manual -24- 5 . Packing transportation and storage 5.1 packing ups main unit is packed in packing-paper carton. The interior volume of the carton ( l × w × h) is:560mm×530mm×170mm. Pay attention to laying direction requirements for each part when packing. The s...

  • Page 29: Appendix

    Rack mount series ups (1~3kva) user ‘s manual -25- appendix 1. Table for led display and working status instruction: output fault batt. Byp. Inv. Line 9# 8# 7# 6# 10# 1# 2# 3# 4# 5# item ups working status alarm led indicator 1# 2# 3# 4# 5# 6# 7# 8# 9# 10# 1 load status 0-25% load silent ○ × × × × ●...

  • Page 30

    Rack mount series ups (1~3kva) user ‘s manual -26- 12 battery status 75%-100% battery 3 beeps every 10 seconds ○ ● ● ● × × ● × ● ● 13 ≥100%battery 3 beeps every 10 seconds ● ● ● ● × × ● × ● ● 14 bypass status (shutdown) silent ▲ ▲ ▲ ▲ ▲ ▲ × ○ ▲ ▲ 15 counter-connection for l, n beeping every 1 minute...

  • Page 31

    Rack mount series ups (1~3kva) user ‘s manual -27- 2、table for lcd display and working status instruction: select line inv. Byp. Batt. Fault lcd display default pages are output pages, in this default page, by pressing the select it will display the input parameters page, the input frequency page, b...