5. Set the lever at the mark between the warm and hot position.
6. Close access door.
CAUTION: The temperature knob or lever is factory adjusted to its lowest dial
setting. We recommend the mid-point position between warm and hot, as noted
above. This will provide for energy efficient operation and sufficient hot water.
Setting at a higher position will produce a higher temperature and increase the risk
of being scalded. Valves for reducing point of use temperature by mixing cold and
hot water are available. Consult a licensed plumber or your local plumbing authority.
Pilot Flame
The gas control pilot has been “preset” for maximum
pilot flow by the manufacturer. (Fig. 5-3)
To Adjust Main Burner
(See Fig. 5-4)
1. Loosen air shutter screw.
2. Slide air shutter to the right until some yellow appears
in the main flame.
3. Move air shutter to left until yellow disappears.
4. Retighten air shutter screw.
Flushing Instructions
The Atwood water heater is recommended for recreational vehicle use. If your folding
camping trailer is used frequently, or taken to different areas that use various types of
water, it is recommended that the water heater be flushed periodically throughout the year
to prolong the life of the inner tank. The following procedure summarizes the steps
necessary for flushing the water heater inner tank.
1. Turn off the main water supply (pump or water hook-up source).
2. Drain your water heater inner tank. Approximately two quarts of water will remain
in the bottom of the tank. This water contains a great deal of the harmful corrosive
material that has accumulated in the tank.
3. Flush tank with air pressure or fresh water to remove remaining water.
Air Pressure: Air pressure may be applied through the inlet or outlet valve located
on the rear of the tank or the relief valve prior to flushing and insert air pressure
through the relief valve support flange.
Fresh Water: Pump fresh water into tank with the assistance of an onboard pump
or external water pressure. This may also be hosed into the tank through the inlet or
outlet valve located on the rear of the tank or the relief valve located on the front of
the unit. If the relief valve is used, remove the relief valve prior to flushing and
insert air pressure through the relief valve support flange. Continue this process for
approximately five minutes allowing ample time for the water to agitate the stagnant
water on the bottom of the tank and thus forcing the depositing through the drain
opening.
4. Close the drain and relief valves.
Fig. 5-4 – Main Burner
& Pilot Assemblies
Fig. 5-3
Pilot Burner Assembly
Robertshaw “Unitrol”
To Turn Off Gas to Furnace
1. Set the thermostat to lowest setting.
2. Turn off all electric power to the appliance if service is to be performed.
3. Open the access panel to turn OFF electric switch or curcuit breaker.
4. Close the control access panel.
WATER HEATER (Optional)
The water heater is optional as part of the deluxe plumbing and shower package.
Heater operates on LP gas only and will need to be lit manually. Operating instructions
are on the following pages and additional instructions will be found in the manual
supplied by manufacturer.
Operation
Pilot Models – G6A-7; GH6-7; G4-7; GC6A-7; and G6A-7P
CAUTION: Do not tamper with the pilot orifice. High water temperature and
failure of the gas control can result.
1. Turn lighting control to “OFF” position.
2. Wait at least five minutes to allow gas which may have accumulated in burner
compartment to escape.
3. Note that your water heater may have either a Robertshaw “Unitrol” or “White
Rodgers” control.
ROBERTSHAW “UNITROL”
1. Turn lighting control dial to “PILOT” position.
2. Depress and hold reset push button while lighting
pilot burner.
3. Allow pilot to burn for one half minute before
releasing button.
4. Turn control dial to “ON” position.
5. If pilot does not remain lit, repeat operation allow-
ing longer period before releasing push button.
6. Set the dial at the mid-point position between warm and hot.
7. Close access door.
“WHITE RODGERS” CONTROL
1. Turn lighting control dial to “PILOT” posi-
tion and hold against stop while lighting pilot
burner.
2. Allow pilot to burn approximately one half
minute before releasing dial.
3. Turn control knob to “ON” position.
4. If pilot does not remain lit, repeat operation
allowing longer period before releasing button or knob.
“White Rodgers” Control