Jbc AL250 Manual - page 3
of
4
3
CHANGING THE HANDPIECE’S CARTRIDGE
ACCESSORIES
AL-IA
HANDS-FREE SOLDERING
ARM AND FUME
EXTRACTOR
F4468
FUME EXTRACTOR
- Loosen the cartridge screw (1) to release the cartridge.
- Place the cartridge in the solder feed handle.
Important: It is essential to insert the cartridge till the end for a good connection.
Use the mark as reference.
- Align the tip of the cartridge with the solder guide tube (2). Tighten the cartridge screw (1).
- You must leave a gap of 8-10 mm between cartridge tip and the end of the guide tube (4). Loosen the
guide screw (3). Adjust the guide tube and tighten screw (3).
Cartridge screw
Guide tube screw
Alignment
1
4
3
2
8-10 mm