JCM Technologies CAP ACTIVE User manual

Manual is about: RadioBand3G System CAPTIVE series

Summary of CAP ACTIVE

  • Page 1

    Jcm technologies captive radioband3g system en cap t868 / cap t916 cap active cap r868 / cap r916 cap magin user manual captive system captive family.

  • Page 2

    Captive system jcm technologies 2 1. Introduction 4 1.1. General description 4 1.2. Cap t868 / 916 transmitter 6 1.3. Cap active transmitter 6 1.4. Cap r868 / 916 receiver 8 1.5. Cap magin 9 2. Detection principles 11 3. Installation 11 3.1. Cap t / cap r 11 3.2. Cap active 14 3.3. Cap magin 16 3.3....

  • Page 3

    Captive system jcm technologies 3 4.3. Connecting the receiver to the control panel 19 4.4. Connecting magin to the receiver 21 5. Adjustment of the reciver / operating modes 22 6. Programming 24 6.1. Programming safety edge to receiver 24 7. Checking and maintenance 26 7.1. Does the equipment work ...

  • Page 4

    Captive system jcm technologies 4 1. Introduction 1.1. General description radio safety solution for industrial sliding gates with no-touch technology. Based on 3 devices: transmitter (cap t868/916, cap active 868), receiver (cap r868/916) and inhibition detector (cap magin). • compatible with all k...

  • Page 5

    Captive system jcm technologies 5 the system complies with en iso 13849-1:2008, category 2, pld. (when the auto-test function is used.).

  • Page 6

    Captive system jcm technologies 6 1.2. Cap t868/916 transmitter – recomended sensibility range adjustment between 5-6.

  • Page 7

    Captive system jcm technologies 7 1.3. Cap active transmitter recommended sensibility range adjustment between 6-7.

  • Page 8

    Captive system jcm technologies 8 1.4. Cap r868/916 receiver.

  • Page 9

    Captive system jcm technologies 9 inh. Gnd. 9 vdc 1.5. Cap magin cap magin detector no touch activated no touch inhibited 2m grey magnets black grey - black magnets position depends on the direction of the gate. Cap magin led must be green while gate is closing. Red when gate is stopped..

  • Page 10

    Captive system jcm technologies 10 2. Detection principles capt detects objects near the safety edge of the gate by detecting variations between conductive part of the gate and conductive parts of the safety edge. For that reason capt has a cable to connect gnd to the metal part of the gate. It is v...

  • Page 11

    Captive system jcm technologies 11 3. Installation 3.1. Cap t/cap r important do not place metal surfaces between transmitter and receiver..

  • Page 12

    Captive system jcm technologies 12 avoid vibrations is a must. Use safety edges where conductor cannot be moved easily by the movement of the door. Use metallic profiles appropriated for the safety edge used. – important to avoid false detections and ensure a longer no touch range, the gap between t...

  • Page 13

    Captive system jcm technologies 13 3.2. Cap active ground cable must be fixed to the gate. Make sure that ground and antenna wires are not in contact..

  • Page 14

    Captive system jcm technologies 14 1-2 cm grey magnet green colour on drawings red colour on drawings black magnet red colour on drawings 3.3. Cap magin magnets: at the gate. Grey magnet should be installed to activate the no-touch sensor when the gate starts the close movement. Black magnet switche...

  • Page 15

    Captive system jcm technologies 15 3.3.1. Fixing the activation magnet with the gate totally opened fix the south field magnet (grey). Grey magnet must be 2-3 cm away from the magin detector. When the door starts closing, the green magnet travels past the magin and no-touch gate sensor is activated....

  • Page 16

    Captive system jcm technologies 16 3.3.2. Fixing the deactivation magnet with the gate at 30-50cm from its closed position: black magnet must be fixed at the other extreme of the gate (in respect of the grey magnet). The location of this magnet depends on the inhibition zone desired. Due to no touch...

  • Page 17

    Captive system jcm technologies 17 4. Connections 4.1. Connecting the cap t (safety edge) ground cable must be fixed to the gate. Make sure that ground and antenna.

  • Page 18

    Captive system jcm technologies 18 4.2. Connecting the cap active (safety edge) check the ground wire is properly fixed and the cable tension is calibrated..

  • Page 19

    Captive system jcm technologies 19 4.3. Connecting the receiver to the control panel connecting the safety outputs to control panel: example: connection to control panel with safety contact / stop input example: connection to control panel with input for safety edge 8k2 the equipment can be connecte...

  • Page 20

    Captive system jcm technologies 20 i n order to comply with en iso 13849-1: 2008 safety standard, a signal to test the system must be connected. When working with optical safety edges, in on mode, only ose-s7502 are allowed as they are kept always active. The radio communication is tested every 7 or...

  • Page 21

    Captive system jcm technologies 21 in work mode, the atest signal is used to power up and down the optical safety edges. The radio communication is tested as in on mode and when the optical elements are powered up and down. 4.4. Connecting magin to the receiver any kind of external signal is suitabl...

  • Page 22

    Captive system jcm technologies 22 5. Adjustment of the reciver / operating modes autocheck period sw1 7 s the system performs a complete test of the equipment, including radio communication. 30 s operating mode with optical safety edges sw2 on in on mode, only "always on" optical safety edges (ose-...

  • Page 23

    Captive system jcm technologies 23 in case of operating without atest signal, it is necessary to work in atest positive way. In order to comply with the en iso 13849-1: 2008 safety standard, you must connect this signal to test the system. On/work mode the operating mode is selected by the sw2 of th...

  • Page 24

    Captive system jcm technologies 24 6. Programming 6.1. Programming safety edge to receiver cap r868/916 receiver can work with standard rb3 transmitters and new cap active/cap t transmitter (no-touch function) at the same time. Inhibition input (switch on and off the no- touch function) will affect ...

  • Page 25

    Captive system jcm technologies 25 before programming, place the options selectors at the desired position. Any subsequent change will require a receiver reset and reprogramming. Press the prog button on receiver and hold it until the desired mode is selected. Led's for r1 & r2 will flash in sequenc...

  • Page 26

    Captive system jcm technologies 26 7. Checking and maintenance 7.1. Does the equipment work properly? Once the safety edge is wired and programmed into the receiver, r1 and / or r2 (according to programming mode) are not illuminated (off). Also in1 and in2 leds at the transmitter are at off. If the ...

  • Page 27

    Captive system jcm technologies 27 7.3. Check function ideal to know the radio coverage on the installation press the receiver’s check button for at least 1 second to enter check mode. The indicator light will come on and four beeps will be heard. Perform a complete door opening and closing manoeuvr...

  • Page 28

    Captive system jcm technologies 28 7.4. Troubleshooting.

  • Page 29

    Captive system jcm technologies 29 7.5. Total reset press prog button on the receiver (1) until the r1 led lights on (2). Keep the programming prog button pressed down and make a bridge with the “mr” reset jumper (3). The receiver will emit 10 warning sound signals (3), and then more at a faster fre...

  • Page 30

    Captive system jcm technologies 30 7.6. Batteries / replacing the cap active transmitter battery remove the end cap of the band where the batteries are located. Storage · store the lithium cells in a cool, dry and ventilated area far from fires and heating sources. · it is recommended the use of a n...

  • Page 31

    Captive system jcm technologies 31 · do not expose the batteries directly to the sun light. · do not put a higher number of cartons one on another (respect what indicated). · if in the same place are storage batteries with a total capacity >50,000ah, it is suggested to install an alarm for smoke and...

  • Page 32

    Captive system jcm technologies 32 8. Technical data summary the manufacturer reserves the right to change the specification of the equipment without prior warning. Cap active 868 cap t868 / cap t916 frequency multifrequency system 868 mhz multifrequency system 868 mhz / multifrequency system 916 mh...

  • Page 33

    Captive system jcm technologies 33 9. Maintenance register cap active safety edge does not need special maintenance, yet a periodic check (every 6 months) is recommended. Each check must be registered. It is recommended to remove any extraneous substances cleaning with exhausters. Check for presence...

  • Page 34

    Captive system jcm technologies 34 10. Important safety instructions see jcm tech youtube page: www.Youtube.Com/jcmtechnologies disconnect the power supply whenever you proceed to the installation or repair of the control panel. In accordance with the european low voltage directive, you are informed...

  • Page 35

    Captive system jcm technologies 35 11. Notes ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ___________________________________...

  • Page 36

    Captive system jcm technologies 36 12. Ec declaration of conformity see website: www.Jcm-tech.Com/en/declarations jcm technologies, s.A. Hereby declares that the products cap active, cap t868/916, cap r868/916 and cap magin complies with the relevant fundamental requirements of the red directive 201...