Jeanneau 57 Owner's Manual - Safety
27/148
ELECTRIC BILGE PUMPS
.
You can energize the electric bilge pump from the electrical panel.
On the electrical panel - three possible positions : OFF / Automatic / Mechanically
operated.
In the automatic position each pump is set off automatically by a trip switch located in the
sump area or in the bottom of the hull.
MANUAL BILGE PUMP
The manual bilge pump is in the cockpit.
The control arm of the pump shall be kept accessible whatever the circumstances.
Location: Forward cabin
Capacity: 70,8 litre / minute
1. Electric bilge pump -
Capacity: 20 litre / minute
2. Automatic bilge pump -
Capacity: 110 litre / minute
Operation:
The electric bilge pumps are connected to the 12V service circuit. To enable operation
the 12V circuit must be activated by turning on the battery switches.
WARNING
- The bilge pump system is not designed to provide buoyancy to the boat
in case of damage.
- The bilge pump system is designed to drive out the water being either
sea spray or leaks but absolutely not the water coming through a hole in
the hull, this hole being the result of a damage.
- Do not let the pumps run while dry, this may cause them damage.
- The water in the bilge shall be kept at its minimum.
- Check the functioning of each bilge pump regularly.
SAFETY PRECAUTIONS
- Clean off debris which could block the pump intake points or strainers. If the watertight
partitions which seal off the fore and aft points are fitted with valves they must be
closed at all times and only opened to drain water into the main bilge.
2