    Af-1 and af-2 fans user manual.

  • Page 2

    680 700 335 320 360 180 af-1 af-2 770 750 310 600 390 400 dimensions all dimensions are in millimeters ©2005-2007 jem / martin professional a/s. All rights reserved. No part of this manual may be reproduced, in any form or by any means, without permission in writing from martin professional a/s. Inf...

  • Page 3: Ontents

    C ontents introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 safety information . . . . . . . . . . . . . . . . . . . . . . . . . ....

  • Page 4

    4 af-1 and af-2 fans user manual connections panels g f e d a c b 1 2 3 4 5 6 7 8 9 10 on h i 12 3 4 56 78 91 0 on a b c d f e g h a – remote in b – power inlet c – main fuseholder d – dmx out (5-pin xlr) e – dmx in (5-pin xlr) f – dmx out (3-pin xlr) g – dmx in (3-pin xlr) h – dip switch i – data l...

  • Page 5: Ntroduction

    Introduction 5 i ntroduction important! Read and save these instructions! Thank you for selecting a jem af series fan. The af-1 and af-2 fans are powerful machines designed for professional and semi-professional use in clubs, tv studios, theaters and touring contexts. They are suitable for a wide ra...

  • Page 6

    6 af-1 and af-2 fans user manual • adjustable flying bracket offering 180° of tilt • can be flown or placed on a flat surface • rugged construction. • sealed high-quality maintenance-free fan motor offers high airflow, high resistance to condensation, ingress of dirt, smoke fluid, etc. And low noise...

  • Page 7

    Introduction 7 • do not spill fluid over the machine. If fluid is spilled, disconnect the machine from power and clean with a damp cloth. If fluid is spilled onto electronic parts, contact an approved jem/martin dealer for advice. • do not dismantle or attempt to repair a faulty machine. Refer all s...

  • Page 8: Nstallation

    8 af-1 and af-2 fans user manual i nstallation this product must be installed by qualified personnel only. A c p o w e r af-1 and af-2 fans are available in two versions: • us version: 115 v, 50/60 hz (for use with 105-115 vac, 60 hz power supplies) • eu version: 230 v, 50/60 hz (for use with 220-24...

  • Page 9

    Installation 9 following the cord cap manufacturer’s instructions, connect the yellow and green wire to ground (earth), the blue wire to neutral and the brown wire to live. The table on page 8 shows some pin identification schemes: p h y s i c a l i n s t a l l a t i o n the af-1 fan may be suspende...

  • Page 10

    10 af-1 and af-2 fans user manual by the clamp manufacturer, through the 13 mm hole in the center of the mounting bracket. • af-2 fan: two rigging options exist. Either: a) bolt two rigging clamps to two martin standard omega brackets (p/n 91602001) using grade 8.8 (minimum) m12 bolts and lock nuts,...

  • Page 11: Nstalling

    Installing control hardware 11 i nstalling control hardware the af-1 and af-2 fans can be operated either using the jem multifunction remote control unit supplied with each machine, or via dmx using a dmx control device and serial data link. The af-1 can also be operated using a 0 - 10 volt dc analo...

  • Page 12

    12 af-1 and af-2 fans user manual a f - 1 1 0 v c o n t r o l i n s t a l l a t i o n af-1 fan speed can be controlled by connecting a suitable analog 0 - 10 volts dc controller via the analog in connector. Up to four machines can be linked on an analog control link. To create an analog control link...

  • Page 13

    Installing control hardware 13 to connect to devices with reversed polarity, use a phase-reversing adaptor (p/n 11820006). To connect the af-1 to a device with a 5-pin output, use a 5-pin male to 3- pin female xlr adaptor cable (p/n 11820005). To connect the af-1 to a device with a 5-pin input, use ...

  • Page 14

    14 af-1 and af-2 fans user manual the dmx address on af-1 and af-2 fans can be set to any channel from 1 to 512 using dip-switch pins 1 - 10: 1. Decide on an available dmx address for each machine. 2. Look up the dip-switch settings using the martin address calculator at http://www.Martin.Dk/service...

  • Page 15

    Installing control hardware 15 d m x a d d r e s s d i p - s w i t c h s e t t i n g s to use this table, first find the dmx address in the main block in the table. Then read the settings for pins 1 - 5 to the left and read the settings for pins 6 - 9 above the address. “0” means off and “1” means o...

  • Page 16: Peration

    16 af-1 and af-2 fans user manual o peration before powering on, check that the fan is correctly and safely installed. U s i n g f a n s w i t h s m o k e m a c h i n e s when using a fan in combination with a smoke machine, fog machine or hazer, place the fan behind the machine, as illustrated on t...

  • Page 17: Jem

    Operation 17 r e m o t e c o n t r o l o p e r a t i o n the multifunction remote control unit supplied with the af-1 and af-2 fans allows instant or timer-controlled fan operation and airflow control. The unit also gives feedback on the status of the machine. 1 0 2 3 4 5 6 7 8 9 10 run on 1 0 2 3 4...

  • Page 18

    18 af-1 and af-2 fans user manual to set timer operation using the remote control: 1. Set the desired amount of airflow using the speed control 2. Set intervals between operating periods by setting the delay control to between 1 and 9. 3. Set duration of operating periods by setting the run control ...

  • Page 19: Ervice

    Service and maintenance 19 s ervice and maintenance any service procedure not described here should be referred to a qualified technician. Warning! Disconnect the fan from power before removing any grills or covers. C l e a n i n g clean the outside of the fan with a damp cloth only. Do not use solv...

  • Page 20

    20 af-1 and af-2 fans user manual af -2 cleaning access 1. Disconnect the fan from power. 2. Remove the 16 cross-head screws from the covers (see illustration above), and remove the covers. 3. Reaching into the fan housing for access to the locking nuts, remove the four 6mm allen screws holding the ...

  • Page 21

    Service and maintenance 21 grommets (a) are seated in the fan housing (b). If this assembly sequence is not respected, the af-2 will be excessively noisy. R e p l a c i n g t h e m a i n f u s e the main fuse can be replaced by the user if necessary. An indication that the main fuse may have blown i...

  • Page 22: Roubleshooting

    22 af-1 and af-2 fans user manual t roubleshooting problem probable cause(s) suggested remedy no light from status leds on remote control or fan no power check power supply and connections remote control not set to standby press standby button remote control not connected check connections fuse blow...

  • Page 23: Af-1

    Af-1 specifications p h y s i c a l dimensions (l x w x h) . . . . . . . . . . . . . . . . . . . . . . . . . . . 320 x 180 x 360 mm (12.6 x 7.1 x 14.2 in.) dimensions in flying bracket (l x w x h) . . . . . . . . . . . . . . 390 x 180 x 400 mm (15.4 x 7.1 x 15.8 in.) weight including flying bracket....

  • Page 24

    I n s t a l l a t i o n orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Any minimum clearance around machine . . . . . . . . . . . . . . . . . . . . . . 0.1 m (4 in.) a p p r o v a l s en 50 081-1 1992 en 50 082-1 1992 en 60 335-1 1995 ...

  • Page 25: Af-2

    Af-2 specifications p h y s i c a l dimensions (l x w x h) . . . . . . . . . . . . . . . . . . . . . . . . . . . 600 x 310 x 600 mm (23.7 x 12.2 x 23.7 in.) dimensions, flying bracket installed (l x w x h) . . . . . . . . 700 x 310 x 680 mm (27.6 x 12.2 x 26.8 in.) dimensions, touring frame installe...

  • Page 26

    C o n n e c t i o n s remote control . 3-pin locking xlr, pin 1 shield, pin 2 +15v, pin 3 signal 0-10v dmx . . . . . . . . . . . . 3-pin locking xlr, pin 1 shield, pin 2 cold (-), pin 3 hot (+) ac power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Iec power inl...

  • Page 28

    Www. Martin. Com • olof palmes allé 18 • 8200 aarhus n • denmark tel: +45 8740 0000 • fax +45 8740 0010

  • Page 29

    Af-2 specifications 29.