JEM Glaciator Dynamic User Manual

Manual is about: low-fog machine

Summary of Glaciator Dynamic

  • Page 1

    User manual p/n 35010046-c read and save these instructions.

  • Page 2

    2 dimensions dimensions 785 mm (30.91 in.) 647 mm (25.49 in.) 769 mm (30.29 in.) 636 mm (25.06 in.) information subject to change without notice. Harman professional denmark aps disclaims liability for any injury, damage, direct or indirect loss, consequential or economic loss or any other loss occa...

  • Page 3

    3 contents dimensions ................................................................................................................................ 2 contents ..................................................................................................................................... 3 sa...

  • Page 4

    4 safety information safety information read the safety precautions in this manual before installing, operating or servicing this product. The following symbols are used to identify important safety information on the product and in this manual: warning! Safety hazard. Risk of severe injury or death...

  • Page 5

    5 preventing electric shocks • always ground (earth) the machine electrically. • use only a source of ac power that complies with local building and electrical codes, and that has both overload and ground-fault protection. • before connecting the machine to power, check that the voltage indicated on...

  • Page 6

    6 safety information • ensure wheels are locked to prevent unintended movement of the machine. • check that all external covers are securely fastened. • do not operate the machine with missing or damaged covers or shields. • in the event of an operating problem, stop using the machine immediately an...

  • Page 7

    7 product overview product descripti on the glaciator dynamic is a low-fog machine designed for a variety of applications such as performance based art, in touring and fixed installations. It can be easily integrated with most control systems currently used in the entertainment industry such as dmx ...

  • Page 8

    8 product overview • (optional accessory) jem glaciator dynamic fog blade for creative output points and waterfall-like low-fog effects • (optional accessory) jem external fluid kit for extended run-time • (optional accessory) jem glaciator dynamic softcover made of reinforced ballistic nylon protec...

  • Page 9

    9 3- & 5-pin dmx in/ out bumper bars / lifting handles condensate sight gauge mains power cable low-fog outlet condensate waste reservoir integrated digital remote control lifting handles 0.5 l condensate waste reservoir product detai ls fast access keypad 5 l low-fog fluid reservoir mains input cir...

  • Page 10

    10 installation and setting up installation and setting up danger! Do not operate the machine until you have read and observed all the precautions listed under “safety information” on page 4. Locatio n the machine is designed to be operated in a dry location on the floor and should be kept in horizo...

  • Page 11

    11 before connecting the machine to power, verify that the ac supply is adequately dimensioned for the current draw of the machine. Check that the local ac voltage is appropriate, as indicated on the machine’s serial number label. If your ac voltage is outside the appropriate range, do not use the m...

  • Page 12

    12 control settings control settings fast access keypad on the rear of the machine, fast access keys are provided to rapidly set the operating mode and parameters of the machine. The prime button activates priming mode. The large round button activates the low-fog output when the system is in a read...

  • Page 13

    13 setting run mod es the run mode menu sets the operational mode of the machine. Settings are off (shutdown, heaters off), standby (heaters on), timer or continuous output mode. Use the menu previous / next buttons to select the run mode option. Use the up/down buttons to select off, standby, timer...

  • Page 14

    14 control settings first set the run time and off time values from the menu using the menu previous / next buttons. The timer values are displayed in the range of 0-250 seconds. Select an interval for the 'on' time; press enter to store the value, set is displayed. Follow the same procedure for the...

  • Page 15

    15 use the menu previous / next buttons to select the link mode option from the settings menu. Use the up/down buttons to select receive 1c (slave unit) or send (master unit). Press the enter button to store the link setting, set is displayed. The machine should be set to send only if it is running ...

  • Page 16

    16 control settings the factory settings are: option setting fog level 50% timer on 10 seconds timer off 20 seconds run mode standby dmx 001 back light norm link mode receive 1c prime no.

  • Page 17

    17 dmx control overvi ew dmx is a digital control language widely used in entertainment and architectural lighting. Any dmx controller meeting the dmx-512a standard may be used to control the machine. A controller that is rdm compliant will be able to program and monitor some settings of the machine...

  • Page 18

    18 dmx control 2 channel mode (receive 2c) channel dmx value range function macro description default value 1 low-fog output level 0-12 idle range none 0 13- 240 output 0- 100% 241 -255 output 100% 2 control functions 0-50 no function 51-100 prime primes the machine 101-150 no function 151-200 off- ...

  • Page 19

    19 you can set an option on one fixture by sending a unicast rdm command to that one fixture only, or you can set the same option on all the fixtures on the data link by sending a broadcast rdm command to all the devices on the link. For status reading, you can only use unicast rdm to read informati...

  • Page 20

    20 optional accessories optional accessories jem glaciator dynamic, ducting kit: p/n 92625020 the glaciator ducting kit is a 3-way low-fog diverter kit that handily affixes to the low-fog outlet of the glaciator. The included ducting adaptor is made of steel and finished in a matte black powder coat...

  • Page 21

    21 approved low-fog fluid types and usage the glaciator dynamic may only be used with the genuine martin jem low-fog fluids listed below. Martin supplies premium quality low-fog fluids that are based on ultra-pure deionized water. No other fluid is suitable for use and such use will void the warrant...

  • Page 22

    22 approved low-fog fluid types and usage and further extends the life of your martin atmospheric effect machines. By using the highest grade chemicals available while remaining eco-friendly, martin fluids are both effective and safe. Instructions for using martin pro-clean and storage fluid can be ...

  • Page 23

    23 maintenance before servicing the machine, read and observe all the precautions listed in “safety information” on page 4. Any service not described in this section must be carried out by a qualified martin service technician. To find your local martin service center visit http://www.Martin.Com/con...

  • Page 24

    24 maintenance the condensate collected in the reservoir cannot be re-used. Dispose of it responsibly. Whenever you replace or fill the low-fog fluid reservoir, always empty the condensate reservoir at the same time. The condensate reservoir should have enough capacity for the condensate generated f...

  • Page 25

    25 filter danger! Disconnect the power supply before removing any covers. Live parts will be exposed when removing the top cover! • under normal conditions (clean and dry environment) inspect and clean/replace the filter every 250 hours of operation • under severe conditions (dirty and/or damp envir...

  • Page 26

    26 troubleshooting troubleshooting problem probable cause(s) suggested remedy machine will not produce low-fog when control panel set to continuous or fog button pressed machine not at operating temperature wait until heat message no longer shown fog option set to 0 increase setting machine in t...

  • Page 27

    27 status messages message reason off the heaters are off, the unit is shut down. If the countdown clock is shown this indicates the shutdown procedure is in progress. Heat the unit is heating up to operating temperature. Ready the heater is at operating temperature, but fog is not turned on (run se...

  • Page 28

    28 specifications specifications physical length ....................................................................................... 785 mm (30.91 in.) width ......................................................................................... 648 mm (25.52 in.) height .........................

  • Page 29

    29 ............................. Includes 1x stainless steel duct clamp, worm drive, hex screw optional external fluid kit .............................................. 25 l sealed fluid reservoir, .......................... 1.5 m (4.9 ft.) 8 mm od, 6 mm id, silicone tubing, pipetta fitting optiona...

  • Page 30

    30 specifications included items: fluid reservoir 5 l ................................................................................ P/n 34300506 fluid reservoir 0.5 l ............................................................................. P/n 34300515 jem glaciator digital remote control .....

  • Page 31

    31 dispo sing o f th is pro duct martin™ products are supplied in compliance with directive 2002/96/ec of the european parliament and of the council of the european union on weee (waste electrical and electronic equipment), as amended by directive 2003/108/ec, where applicable. Help preserve the env...

  • Page 32

    Www.Martin.Com • olof palmes allé 18 • 8200 aarhus n • denmark tel: +45 7020 7309 • fax: +45 8740 0010