    5 x 0 0 c y l i n d r i c a l installation instructions.

  • Page 2

    2 3 table of contents model e5031 assembly drawing (model e5031) 3 tools required 3 a. Door preparation 4 b. Lock handing 5 c. Door thickness 5 d. Installing outside unit assembly 6 e. Installing inside unit assembly 6-7 f. Installing inside lever/knob 7 g. Changing key-in-lever/knob (kil/kik) cylin...

  • Page 3

    4 5 b. Lock handing the e-plex 5000 is a non-handed lock that is preassembled for left-hand door installations. B-1 determine the hand of your door. For left hand doors, proceed to section c. For right hand doors, follow steps in b-2. B-2 remove the two connecting screws (a) from the cylindrical dri...

  • Page 4

    6 7 e-3 insert lectrobolt through the red inside housing hole marked with the lightening bolt symbol. For now, only partially tighten the lectro bolt to keep the red collars in position. Then, insert and tighten the other three mounting bolts. Finish tightening the lectrobolt to secure the lock on t...

  • Page 5

    Ka ba ac ce ss co nt ro l 29 41 in di an a av en ue w in st o n- sa le m ,n c 27 19 9- 37 70 no post age necessar y if mailed in the united st ates b u s in e s s r e p l y m a il fi rs t- cl as s m ai l pe rm it no .1 56 3 po st ag e w il l be pa id by ad d r es se e w in st o n- sa le m ,n c kaba ...

  • Page 6

    Notes thank you for purchasing our product. In order to protect your investment and to enable us to better se rve yo u in the futu re, ple as e fill ou tth is reg istr atio n card and return it to kaba access control, or register online at www .Kabaaccess.Com . T h is lo c k w ill b e u s e d in w h...

  • Page 7

    G-3 assemble the required tailpiece (d) (supplied) with your kil/kik cylinder. All tailpieces must be installed vertically (with key removed from cylinder) for proper installation. G-4 insert the kil/kik cylinder (a) into the outside lever/knob (b) and secure it with the cylinder retainer (c) and le...

  • Page 8

    10 11 i-3 insert the supplied tailpiece (e) vertically into the outside lever/knob (b) as shown. Make certain that you rotate the tailpiece so it will align with the inter- changeable core. For screw cap type cylinders (schlage) (g), the tailpiece must be assembled to the cylinder first with the tai...

  • Page 9

    12 13 k. Testing the operation of the lock k-1 rotate inside lever/knob and hold. Ensure that the latch is fully retracted and flush with the latch faceplate. Release the inside lever/knob; the latch should be fully extended. K-2 enter the factory-set combination: 1,2,3,4,5,6,7,8. You should see a g...

  • Page 10

    15 14 note: for security reasons, all existing audit events are not deleted. The lock is now set to the factory-configured setup with the default factory master code, 1,2,3,4,5,6,7,8. Important: before you can program the lock you must first enter a new 8 digit master code of your choice. For exampl...

  • Page 11

    Kaba access control 2941 indiana avenue winston-salem, nc 27105 usa tel: (800) 849-8324 (336) 725-1331 fax: (800) 346-9640 (336) 725-3269 www.Kabaaccess.Com www.E-plexlock.Com pkg2992 1206.