Kairak KRES Instruction Manual - Fig. 5

Manual is about: Equipment Stands Self-Contained and Remote

Summary of KRES

  • Page 1

    Kairak im-es-rev 5-09-06 500 s. State college blvd. Fullerton, ca 92831 pn 4406010-1 a div of itw feg, llc. Instruction manual kres equipment stands self-contained and remote.

  • Page 2: General

    Kairak page 2 - 2 - im-es-rev 5-09-06.Doc5-09-06 general kairak kres model refrigerated equipment stand units are available in many lengths from 36 to 120 inches long. These units are available as a refrigerated or freezer storage compartment. The condensing systems are designed to be installed with...

  • Page 3: Fig. 2

    Kairak page 3 - 3 - im-es-rev 5-09-06.Doc5-09-06 locating the equipment all model lengths can be installed with minimal clearance at the back and sides of the units installing parts shipped loose compressor filter remove louvered panel by lifting up and pulling out entire panel. Slide the filter int...

  • Page 4: Fig. 3

    Kairak page 4 - 4 - im-es-rev 5-09-06.Doc5-09-06 electric condensate evaporator some units may come with the electric condensate evaporator shipped loose. To install, attach the two (2) mounting rails to the bottom of the cabinet with 4 or 6 (depending on the model) #6- 32 x 3/8 phillips head screws...

  • Page 5: Electrical Connections

    Kairak page 5 - 5 - im-es-rev 5-09-06.Doc5-09-06 refrigeration lines (remote units) warning: refrigeration lines are shipped under pressure. Use caution when opening lines. On remote units, refrigeration lines for suction and supply are located on the back of the unit near the bottom. The suction li...

  • Page 6: Prestart Checks

    Kairak page 6 - 6 - im-es-rev 5-09-06.Doc5-09-06 prestart checks defrost time clock settings all models have a defrost time clock that is set to defrost 3 times a day for a 15 minute time period. The defrost settings are factory set at 12:00 a.M. To 1:00 a.M., 2:00 a.M. To 2:30 a.M. And 5:00 a.M. To...

  • Page 7: Fig. 5

    Kairak page 7 - 7 - im-es-rev 5-09-06.Doc5-09-06 temperature control settings all temperature settings are preset at the factory but local conditions may necessitate slight adjustments. On self-contained refrigerated modelsthe temperature control (shown in fig. 5) is located in the compressor compar...

  • Page 8: Fig. 6

    Kairak page 8 - 8 - im-es-rev 5-09-06.Doc5-09-06 on remote models, the controls can either be inside the control cabinet similar to that shown in fig. 5 or inside the refrigerated base as shown in fig. 6. Kres remote fig. 6 on both self-contained and remote refrigerated units, the temperature contro...

  • Page 9: Operation

    Kairak page 9 - 9 - im-es-rev 5-09-06.Doc5-09-06 operation a thermometer is provided on all refrigerator and freezer cabinets. Allow cabinet to reach normal operating temperature before loading (approximately 1 hour). The refrigerated storage cabinet is designed to maintain temperatures between 33 °...

  • Page 10: Fig. 7

    Kairak page 10 - 10 - im-es-rev 5-09-06.Doc5-09-06 fig. 7 fig. 8 cross rail lock cross rail lock (1 on each side of drawer) drawer module liner lock black clamping knob black clamping knob.

  • Page 11

    Kairak page 11 - 11 - im-es-rev 5-09-06.Doc5-09-06 condensing unit warning: disconnect electrical power supply before cleaning any parts on the unit. The condensing unit coil and filter must be cleaned regularly on self-contained models for optimal performance. The operating environment will affect ...

  • Page 12: Troubleshooting

    Kairak page 12 - 12 - im-es-rev 5-09-06.Doc5-09-06 troubleshooting symptom possible cause compressor fails to operate. • power failure. • plug loose in receptacle or unplugged. • blown fuse or tripped circuit breaker. • main power switch is off. • temperature controls or time clock not set properly....

  • Page 13

    Kairak page 13 - 13 - im-es-rev 5-09-06.Doc5-09-06 a div of itw feg, llc. 1-year labor warranty kairak warrants that equipment manufactured by kairak will be free from defects in material and workmanship for a period of 1-year beginning 30 days after ship date. All work must be pre -approved by the ...